Toward Optimizing Cervical Vestibular Evoked Myogenic Potentials (cVEMP): Combining Air-Bone Gap and cVEMP Thresholds to Improve Diagnosis of Superior Canal Dehiscence. Issue 2 (February 2018)
- Record Type:
- Journal Article
- Title:
- Toward Optimizing Cervical Vestibular Evoked Myogenic Potentials (cVEMP): Combining Air-Bone Gap and cVEMP Thresholds to Improve Diagnosis of Superior Canal Dehiscence. Issue 2 (February 2018)
- Main Title:
- Toward Optimizing Cervical Vestibular Evoked Myogenic Potentials (cVEMP)
- Authors:
- Noij, Kimberley S.
Duarte, Maria J.
Wong, Kevin
Cheng, Y. Song
Masud, Salwa
Herrmann, Barbara S.
Curtin, Hugh D.
Kanumuri, Vivek V.
Guinan, John J.
Kozin, Elliott D.
Tarabichi, Osama
Jung, David H.
Lee, Daniel J.
Rauch, Steven D. - Abstract:
- Abstract : Objective: To develop a novel approach combining low-frequency air-bone gap (ABG) and cervical vestibular evoked myogenic potential (cVEMP) thresholds to improve screening for superior canal dehiscence (SCD) syndrome. Study Design: Retrospective study. Setting: Tertiary care center. Patients: One hundred forty patients with SCD and 21 healthy age-matched controls were included. Ears for each patient were divided into three groups based on computed tomography (CT) findings: 1) dehiscent, 2) thin, or 3) unaffected. Main Outcome Measures: cVEMP and audiometric thresholds were analyzed and differences among groups were evaluated. Results: We define the third window indicator (TWI) as the cVEMP thresholds at 500, 750, and 1000 Hz adjusted for the ABG at 250 Hz (i.e., subtracting ABG from cVEMP threshold). The TWI differentiates between dehiscent and nondehiscent control ears with a sensitivity of 82% and specificity of 100%, corresponding to a positive predictive value of 100%. ABGs and cVEMP thresholds were similar for healthy controls and patients with thin bone over the superior canal. Conclusion: This is the largest study to date examining the usefulness of cVEMPs in the diagnosis of SCD. Our "third window indicator" (TWI) combines cVEMP thresholds with the ABG at 250 Hz to improve the ability to screen patients with SCD symptoms
- Is Part Of:
- Otology & neurotology. Volume 39:Issue 2(2018)
- Journal:
- Otology & neurotology
- Issue:
- Volume 39:Issue 2(2018)
- Issue Display:
- Volume 39, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 39
- Issue:
- 2
- Issue Sort Value:
- 2018-0039-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-02
- Subjects:
- Air-bone gap -- Cervical vestibular evoked myogenic potential -- Semicircular canal dehiscence
Otology -- Periodicals
Ear -- Diseases -- Periodicals
Skull base -- Surgery -- Periodicals
617.8005 - Journal URLs:
- http://www.otology-neurotology.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAO.0000000000001655 ↗
- Languages:
- English
- ISSNs:
- 1531-7129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6313.528000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9048.xml