- Abstract : Purpose: Retroprosthetic membrane (RPM) formation is the most common complication after Boston type 1 keratoprosthesis (KPro) implantation. It affects visual acuity and can predispose to corneal melt. Two KPro backplate materials are available: titanium and polymethyl methacrylate (PMMA). This study investigates the influence of the KPro backplate material on visually significant RPM formation. Methods: A retrospective case–control-matched study involving 40 patients; 20 eyes implanted with a titanium backplate KPro were case-matched with 20 eyes implanted with a PMMA backplate KPro between 2007 and 2015 with 1-year minimum follow-up. Results: The mean follow-up duration was 28.1 ± 8.9 and 53.6 ± 24.3 months in the titanium and PMMA groups, respectively. At 12 months postoperatively, 7 eyes with titanium and 6 eyes with PMMA backplates developed a visually significant RPM. By the end of the study, a total of 11 eyes with titanium and 9 eyes with PMMA KPros developed a visually significant RPM. There was no statistically significant difference between both groups. Three of 11 eyes with titanium KPros that had a visually significant RPM required surgical membranectomy, whereas all eyes with PMMA KPros were successfully treated with the yttrium-aluminum-garnet laser. Recurrence of RPMs was found in 7/11 eyes in the titanium group and 2/9 eyes in the PMMA group with no statistical significance. Conclusions: Titanium backplate KPros do not significantly reduce RPMAbstract : Purpose: Retroprosthetic membrane (RPM) formation is the most common complication after Boston type 1 keratoprosthesis (KPro) implantation. It affects visual acuity and can predispose to corneal melt. Two KPro backplate materials are available: titanium and polymethyl methacrylate (PMMA). This study investigates the influence of the KPro backplate material on visually significant RPM formation. Methods: A retrospective case–control-matched study involving 40 patients; 20 eyes implanted with a titanium backplate KPro were case-matched with 20 eyes implanted with a PMMA backplate KPro between 2007 and 2015 with 1-year minimum follow-up. Results: The mean follow-up duration was 28.1 ± 8.9 and 53.6 ± 24.3 months in the titanium and PMMA groups, respectively. At 12 months postoperatively, 7 eyes with titanium and 6 eyes with PMMA backplates developed a visually significant RPM. By the end of the study, a total of 11 eyes with titanium and 9 eyes with PMMA KPros developed a visually significant RPM. There was no statistically significant difference between both groups. Three of 11 eyes with titanium KPros that had a visually significant RPM required surgical membranectomy, whereas all eyes with PMMA KPros were successfully treated with the yttrium-aluminum-garnet laser. Recurrence of RPMs was found in 7/11 eyes in the titanium group and 2/9 eyes in the PMMA group with no statistical significance. Conclusions: Titanium backplate KPros do not significantly reduce RPM formation compared with PMMA backplate KPros in a case–control-matched setting. A larger prospective study is warranted to evaluate comparative long-term performance and guide newer designs. … (more)
- Is Part Of:
- Cornea. Volume 37:Issue 2(2018)
- Journal:
- Cornea
- Issue:
- Volume 37:Issue 2(2018)
- Issue Display:
- Volume 37, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 37
- Issue:
- 2
- Issue Sort Value:
- 2018-0037-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-02
- Subjects:
- Boston keratoprosthesis (KPro) -- retroprosthetic membrane (RPM) -- titanium backplate -- PMMA backplate
Cornea -- Periodicals
Cornea -- Periodicals
Cornée -- Périodiques
617.719 - Journal URLs:
- http://journals.lww.com/corneajrnl/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICO.0000000000001462 ↗
- Languages:
- English
- ISSNs:
- 0277-3740
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3470.927500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9035.xml