Measurement of Active and Sedentary Behavior in Context of Large Epidemiologic Studies. Issue 2 (February 2018)
- Record Type:
- Journal Article
- Title:
- Measurement of Active and Sedentary Behavior in Context of Large Epidemiologic Studies. Issue 2 (February 2018)
- Main Title:
- Measurement of Active and Sedentary Behavior in Context of Large Epidemiologic Studies
- Authors:
- MATTHEWS, CHARLES E.
KOZEY KEADLE, SARAH
MOORE, STEVEN C.
SCHOELLER, DALE S.
CARROLL, RAYMOND J.
TROIANO, RICHARD P.
SAMPSON, JOSHUA N. - Abstract:
- ABSTRACT: Introduction/Purpose: To assess the utility of measurement methods that may be more accurate and precise than traditional questionnaire-based estimates of habitual physical activity and sedentary behavior we compared the measurement properties of a past year questionnaire (AARP) and more comprehensive measures: an internet-based 24-h recall (ACT24), and a variety of estimates from an accelerometer (ActiGraph). Methods: Participants were 932 adults (50–74 yr) in a 12-month study that included reference measures of energy expenditure from doubly labeled water (DLW) and active and sedentary time via activPAL. Results: Accuracy at the group level (mean differences) was generally better for both ACT24 and ActiGraph than the AARP questionnaire. The AARP accuracy for energy expenditure ranged from −4% to −13% lower than DLW, but its accuracy was poorer for physical activity duration (−48%) and sedentary time (−18%) versus activPAL. In contrast, ACT24 accuracy was within 3% to 10% of DLW expenditure measures and within 1% to 3% of active and sedentary time from activPAL. For ActiGraph, accuracy for energy expenditure was best for the Crouter 2-regression method (−2% to −7%), and for active and sedentary time the 100 counts per minute cutpoint was most accurate (−1% to 2%) at the group level. One administration of the AARP questionnaire was significantly correlated with long-term average from the reference measures (ρTX = 0.16–0.34) overall, but four ACT24 recalls hadABSTRACT: Introduction/Purpose: To assess the utility of measurement methods that may be more accurate and precise than traditional questionnaire-based estimates of habitual physical activity and sedentary behavior we compared the measurement properties of a past year questionnaire (AARP) and more comprehensive measures: an internet-based 24-h recall (ACT24), and a variety of estimates from an accelerometer (ActiGraph). Methods: Participants were 932 adults (50–74 yr) in a 12-month study that included reference measures of energy expenditure from doubly labeled water (DLW) and active and sedentary time via activPAL. Results: Accuracy at the group level (mean differences) was generally better for both ACT24 and ActiGraph than the AARP questionnaire. The AARP accuracy for energy expenditure ranged from −4% to −13% lower than DLW, but its accuracy was poorer for physical activity duration (−48%) and sedentary time (−18%) versus activPAL. In contrast, ACT24 accuracy was within 3% to 10% of DLW expenditure measures and within 1% to 3% of active and sedentary time from activPAL. For ActiGraph, accuracy for energy expenditure was best for the Crouter 2-regression method (−2% to −7%), and for active and sedentary time the 100 counts per minute cutpoint was most accurate (−1% to 2%) at the group level. One administration of the AARP questionnaire was significantly correlated with long-term average from the reference measures (ρTX = 0.16–0.34) overall, but four ACT24 recalls had higher correlations (ρTX = 0.48–0.60), as did 4 d of ActiGraph assessment (ρTX = 0.54–0.87). Conclusions: New exposure assessments suitable for use in large epidemiologic studies (ACT24, ActiGraph) were more accurate and had higher correlations than a traditional questionnaire. Use of better more comprehensive measures in future epidemiologic studies could yield new etiologic discoveries and possibly new opportunities for prevention. Abstract : Supplemental digital content is available in the text. … (more)
- Is Part Of:
- Medicine and science in sports and exercise. Volume 50:Issue 2(2018)
- Journal:
- Medicine and science in sports and exercise
- Issue:
- Volume 50:Issue 2(2018)
- Issue Display:
- Volume 50, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 50
- Issue:
- 2
- Issue Sort Value:
- 2018-0050-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-02
- Subjects:
- ACCELEROMETER -- CALIBRATION -- EXERCISE -- MEASUREMENT ERROR -- POSTURE -- SITTING
Sports medicine -- Periodicals
Exercise -- Physiological aspects -- Periodicals
Exercise -- Health aspects -- Periodicals
612.044 - Journal URLs:
- http://journals.lww.com/acsm-msse/pages/default.aspx ↗
http://www.ms-se.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1249/MSS.0000000000001428 ↗
- Languages:
- English
- ISSNs:
- 0195-9131
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.006700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9035.xml