End-Tidal Carbon Dioxide Use for Tracheal Intubation: Analysis From the National Emergency Airway Registry for Children (NEAR4KIDS) Registry. Issue 2 (February 2018)
- Record Type:
- Journal Article
- Title:
- End-Tidal Carbon Dioxide Use for Tracheal Intubation: Analysis From the National Emergency Airway Registry for Children (NEAR4KIDS) Registry. Issue 2 (February 2018)
- Main Title:
- End-Tidal Carbon Dioxide Use for Tracheal Intubation
- Authors:
- Langhan, Melissa L.
Emerson, Beth L.
Nett, Sholeen
Pinto, Matthew
Harwayne-Gidansky, Ilana
Rehder, Kyle J.
Krawiec, Conrad
Meyer, Keith
Giuliano, John S.
Owen, Erin B.
Tarquinio, Keiko M.
Sanders, Ron C.
Shepherd, Michael
Bysani, Gokul Kris
Shenoi, Asha N.
Napolitano, Natalie
Gangadharan, Sandeep
Parsons, Simon J.
Simon, Dennis W.
Nadkarni, Vinay M.
Nishisaki, Akira - Abstract:
- Abstract : Objective: Waveform capnography use has been incorporated into guidelines for the confirmation of tracheal intubation. We aim to describe the trend in waveform capnography use in emergency departments and PICUs and assess the association between waveform capnography use and adverse tracheal intubation–associated events. Design: A multicenter retrospective cohort study. Setting: Thirty-four hospitals (34 ICUs and nine emergency departments) in the National Emergency Airway Registry for Children quality improvement initiative. Patients: Primary tracheal intubation in children younger than 18 years. Interventions: None. Measurements and Main Results: Patient, provider, and practice data for tracheal intubation procedure including a type of end-tidal carbon dioxide measurement, as well as the procedural safety outcomes, were prospectively collected. The use of waveform capnography versus colorimetry was evaluated in association with esophageal intubation with delayed recognition, cardiac arrest, and oxygen desaturation less than 80%. During January 2011 and December 2015, 9, 639 tracheal intubations were reported. Waveform capnography use increased over time (39% in 2010 to 53% in 2015; p < 0.001), whereas colorimetry use decreased (< 0.001). There was significant variability in waveform capnography use across institutions (median 49%; interquartile range, 25–85%; p < 0.001). Capnography was used more often in emergency departments as compared with ICUs (66% vs. 49%;Abstract : Objective: Waveform capnography use has been incorporated into guidelines for the confirmation of tracheal intubation. We aim to describe the trend in waveform capnography use in emergency departments and PICUs and assess the association between waveform capnography use and adverse tracheal intubation–associated events. Design: A multicenter retrospective cohort study. Setting: Thirty-four hospitals (34 ICUs and nine emergency departments) in the National Emergency Airway Registry for Children quality improvement initiative. Patients: Primary tracheal intubation in children younger than 18 years. Interventions: None. Measurements and Main Results: Patient, provider, and practice data for tracheal intubation procedure including a type of end-tidal carbon dioxide measurement, as well as the procedural safety outcomes, were prospectively collected. The use of waveform capnography versus colorimetry was evaluated in association with esophageal intubation with delayed recognition, cardiac arrest, and oxygen desaturation less than 80%. During January 2011 and December 2015, 9, 639 tracheal intubations were reported. Waveform capnography use increased over time (39% in 2010 to 53% in 2015; p < 0.001), whereas colorimetry use decreased (< 0.001). There was significant variability in waveform capnography use across institutions (median 49%; interquartile range, 25–85%; p < 0.001). Capnography was used more often in emergency departments as compared with ICUs (66% vs. 49%; p < 0.001). The rate of esophageal intubation with delayed recognition was similar with waveform capnography versus colorimetry (0.39% vs. 0.46%; p = 0.62). The rate of cardiac arrest was also similar ( p = 0.49). Oxygen desaturation occurred less frequently when capnography was used (17% vs. 19%; p = 0.03); however, this was not significant after adjusting for patient and provider characteristics. Conclusions: Significant variations existed in capnography use across institutions, with the use increasing over time in both emergency departments and ICUs. The use of capnography during intubation was not associated with esophageal intubation with delayed recognition or the occurrence of cardiac arrest. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Pediatric critical care medicine. Volume 19:Issue 2(2018)
- Journal:
- Pediatric critical care medicine
- Issue:
- Volume 19:Issue 2(2018)
- Issue Display:
- Volume 19, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 19
- Issue:
- 2
- Issue Sort Value:
- 2018-0019-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-02
- Subjects:
- capnography -- child -- colorimetry -- intubation -- pediatric intensive care unit
Pediatric intensive care -- Periodicals
Pediatric emergencies -- Periodicals
618.05 - Journal URLs:
- http://www.mdconsult.com/public/search?search_type=journal&j_sort=pub_date&j_issn=1529-7535 ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00130478-000000000-00000 ↗
http://journals.lww.com/pccmjournal/pages/default.aspx ↗
http://www.mdconsult.com/about/journallist/192093418-5/about0041.html ↗
http://www.pccmjournal.com/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/PCC.0000000000001372 ↗
- Languages:
- English
- ISSNs:
- 1529-7535
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6417.565000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9035.xml