Compatibility of ZOLL Defibrillators in Simulation-Based Training. Issue 1 (February 2018)
- Record Type:
- Journal Article
- Title:
- Compatibility of ZOLL Defibrillators in Simulation-Based Training. Issue 1 (February 2018)
- Main Title:
- Compatibility of ZOLL Defibrillators in Simulation-Based Training
- Authors:
- Shoemaker, Jamie Leigh
Duty, Olivia T.
Martin, Kenneth J.
Geis, Gary L. - Abstract:
- Abstract : Introduction: In response to the need for high-quality cardiopulmonary resuscitation (CPR) during cardiac arrest, our institution recently purchased ZOLL R Series monitor/defibrillators. This defibrillator provides CPR quality metrics and displays a filtered rhythm through compressions. Purchase of this defibrillator resulted in a practice change and heavily impacted our simulation-based training courses by requiring providers to practice CPR and defibrillation in as close to the real environment as possible. Thus, our objective was to determine which commercial simulators would be compatible with the ZOLL R Series defibrillator system and its CPR feedback functionality in a simulation-based training setting. Methods: Our simulation center uses primarily Gaumard Scientific and Laerdal Medical simulators ranging in size from neonate to adult. Through an iterative process in the laboratory, we evaluated if, and to what level, the CPR display metrics, filtered rhythm, and idle time display could be demonstrated with CPR on the different simulators using infant, pediatric, and adult pads. Results: Certain simulators allow demonstration and real-time practice of defibrillator functions better than others with the ZOLL R Series system when used in the context of CPR training. We have no high-fidelity infant-sized simulators that can meet the depth recommendation for chest compressions given by the American Heart Association. Ventricular fibrillation is the only rhythmAbstract : Introduction: In response to the need for high-quality cardiopulmonary resuscitation (CPR) during cardiac arrest, our institution recently purchased ZOLL R Series monitor/defibrillators. This defibrillator provides CPR quality metrics and displays a filtered rhythm through compressions. Purchase of this defibrillator resulted in a practice change and heavily impacted our simulation-based training courses by requiring providers to practice CPR and defibrillation in as close to the real environment as possible. Thus, our objective was to determine which commercial simulators would be compatible with the ZOLL R Series defibrillator system and its CPR feedback functionality in a simulation-based training setting. Methods: Our simulation center uses primarily Gaumard Scientific and Laerdal Medical simulators ranging in size from neonate to adult. Through an iterative process in the laboratory, we evaluated if, and to what level, the CPR display metrics, filtered rhythm, and idle time display could be demonstrated with CPR on the different simulators using infant, pediatric, and adult pads. Results: Certain simulators allow demonstration and real-time practice of defibrillator functions better than others with the ZOLL R Series system when used in the context of CPR training. We have no high-fidelity infant-sized simulators that can meet the depth recommendation for chest compressions given by the American Heart Association. Ventricular fibrillation is the only rhythm that offers a filtered option. Idle time can be reliably displayed for simulators where CPR is detected. Conclusions: When a primary learning objective for simulation-based training involves training on the ZOLL R Series defibrillator, there are a limited number of simulators and rhythms that can accurately represent its features. … (more)
- Is Part Of:
- Simulation in healthcare. Volume 13:Issue 1(2018)
- Journal:
- Simulation in healthcare
- Issue:
- Volume 13:Issue 1(2018)
- Issue Display:
- Volume 13, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 13
- Issue:
- 1
- Issue Sort Value:
- 2018-0013-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-02
- Subjects:
- CPR -- defibrillator -- simulation
Simulated patients -- Periodicals
362.1 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01253104-000000000-00000 ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01266021-000000000-00000 ↗
http://journals.lww.com/simulationinhealthcare/pages/default.aspx ↗
http://www.simulationinhealthcare.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/SIH.0000000000000259 ↗
- Languages:
- English
- ISSNs:
- 1559-2332
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8285.164020
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9013.xml