A Case Study of the NCRP 156 Wound Model of Embedded DU Using Data From Urine Uranium Concentrations of Wounded Veterans. Issue 3 (March 2018)
- Record Type:
- Journal Article
- Title:
- A Case Study of the NCRP 156 Wound Model of Embedded DU Using Data From Urine Uranium Concentrations of Wounded Veterans. Issue 3 (March 2018)
- Main Title:
- A Case Study of the NCRP 156 Wound Model of Embedded DU Using Data From Urine Uranium Concentrations of Wounded Veterans
- Authors:
- Walkingstick, Michael T.
Krage, Eric S.
Brey, Richard R. - Abstract:
- Abstract : Abstract: Depleted uranium (DU) munitions were initially used by the United States (U.S.) military during the first Persian Gulf War in 1991 in order to penetrate heavily armored vehicles. However, as a result of friendly fire, several U.S. military personnel received intakes from DU munitions. One of the ongoing concerns for these wounded veterans is the potential long-term exposure received from DU embedded fragments. The United States Army Institute of Public Health (AIPH) is the first laboratory that analyzes the urine bioassays from Army Soldiers that are injured with DU fragments. The United States Air Force School of Aerospace Medicine also evaluates bioassays from DU injuries. The urine bioassay data collected by AIPH was evaluated using the NCRP 156 wound model coefficients for the DU-Wafer, Fragment, and Particle models. The maximum likelihood method was used in the Integrated Modules for Bioassay Analysis (IMBA-PPAE) to calculate the estimates of intake and tissue doses. Evaluating the three models for wound retention, the DU-Wafer and Fragment model yielded a credible fit to the bioassay data. Comparing the two models, the DU-Wafer model fits the data better than the Fragment model when comparing their autocorrelation coefficient and chi-squared values of (P 1.73 × 10 −1, c 2 4.83 × 10 −1 ), (P 2.01 × 10 −2, c 2 1.09), respectively. This evaluation supports the validity of both the DU-wafer model as well as the default fragmentation model proposed byAbstract : Abstract: Depleted uranium (DU) munitions were initially used by the United States (U.S.) military during the first Persian Gulf War in 1991 in order to penetrate heavily armored vehicles. However, as a result of friendly fire, several U.S. military personnel received intakes from DU munitions. One of the ongoing concerns for these wounded veterans is the potential long-term exposure received from DU embedded fragments. The United States Army Institute of Public Health (AIPH) is the first laboratory that analyzes the urine bioassays from Army Soldiers that are injured with DU fragments. The United States Air Force School of Aerospace Medicine also evaluates bioassays from DU injuries. The urine bioassay data collected by AIPH was evaluated using the NCRP 156 wound model coefficients for the DU-Wafer, Fragment, and Particle models. The maximum likelihood method was used in the Integrated Modules for Bioassay Analysis (IMBA-PPAE) to calculate the estimates of intake and tissue doses. Evaluating the three models for wound retention, the DU-Wafer and Fragment model yielded a credible fit to the bioassay data. Comparing the two models, the DU-Wafer model fits the data better than the Fragment model when comparing their autocorrelation coefficient and chi-squared values of (P 1.73 × 10 −1, c 2 4.83 × 10 −1 ), (P 2.01 × 10 −2, c 2 1.09), respectively. This evaluation supports the validity of both the DU-wafer model as well as the default fragmentation model proposed by NCRP 156. … (more)
- Is Part Of:
- Health physics. Volume 114:Issue 3(2018:Mar.)
- Journal:
- Health physics
- Issue:
- Volume 114:Issue 3(2018:Mar.)
- Issue Display:
- Volume 114, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 114
- Issue:
- 3
- Issue Sort Value:
- 2018-0114-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-03
- Subjects:
- operational topics -- 238U -- contamination, internal -- National Council of Radiation Protection and Measurements
Biophysics -- Periodicals
Health Physics -- periodicals
Radiation Protection -- periodicals
Radiotherapy -- periodicals
Medische fysica
Electronic journals
612.01448 - Journal URLs:
- http://journals.lww.com/health-physics/pages/default.aspx ↗
http://www.health-physics.com ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/HP.0000000000000816 ↗
- Languages:
- English
- ISSNs:
- 0017-9078
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4275.100000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9012.xml