Reset charge sensitive amplifier for NaI(Tl) gamma-ray spectrometer. (March 2015)
- Record Type:
- Journal Article
- Title:
- Reset charge sensitive amplifier for NaI(Tl) gamma-ray spectrometer. (March 2015)
- Main Title:
- Reset charge sensitive amplifier for NaI(Tl) gamma-ray spectrometer
- Authors:
- Zeng, Guoqiang
Tan, Chengjun
Li, Qiang
Ge, Liangquan
Liu, Xiyao
Luo, Qun - Abstract:
- Abstract: The time constant of the output signal of the front-end readout circuit of a traditional gamma-ray spectrometer with a NaI(Tl)+PMT structure is affected by temperature, measurement environment and the signal transmission cable, so it is difficult to get a good resolution spectrum, especially at higher counting rates. In this paper, a reset charge sensitive amplifier (RCSA) is designed for the gamma-ray spectrometer with a NaI(Tl)+PMT structure. The designed RCSA outputs a step signal, thus enabling the acquisition of double-exponential signals with a stable time constant by using the next stage of a CR differentiating circuit. The designed RCSA is mainly composed of a basic amplifying circuit, a reset circuit and a dark current compensation circuit. It provides the output step signal through the integration of the PMT output charge signal. When the amplitude of the step signal exceeds a preset voltage threshold, it triggers the reset circuit to generate a reset pulse (about 5 µs pulse width) to reset the output signal. Experimental results demonstrated that the designed RCSA achieves a charge sensitivity of 4.26×10 10 V/C, with a zero capacitance noise of 51.09 fC and a noise slope of 1.98 fC/pF. Supported by the digital shaping algorithm of the digital multi-channel analyzer (DMCA), it can maintain good energy resolution with high counting rates up to 150 kcps and with a temperature range from −19 °C to 50 °C. Highlights: A new reset type charge sensitiveAbstract: The time constant of the output signal of the front-end readout circuit of a traditional gamma-ray spectrometer with a NaI(Tl)+PMT structure is affected by temperature, measurement environment and the signal transmission cable, so it is difficult to get a good resolution spectrum, especially at higher counting rates. In this paper, a reset charge sensitive amplifier (RCSA) is designed for the gamma-ray spectrometer with a NaI(Tl)+PMT structure. The designed RCSA outputs a step signal, thus enabling the acquisition of double-exponential signals with a stable time constant by using the next stage of a CR differentiating circuit. The designed RCSA is mainly composed of a basic amplifying circuit, a reset circuit and a dark current compensation circuit. It provides the output step signal through the integration of the PMT output charge signal. When the amplitude of the step signal exceeds a preset voltage threshold, it triggers the reset circuit to generate a reset pulse (about 5 µs pulse width) to reset the output signal. Experimental results demonstrated that the designed RCSA achieves a charge sensitivity of 4.26×10 10 V/C, with a zero capacitance noise of 51.09 fC and a noise slope of 1.98 fC/pF. Supported by the digital shaping algorithm of the digital multi-channel analyzer (DMCA), it can maintain good energy resolution with high counting rates up to 150 kcps and with a temperature range from −19 °C to 50 °C. Highlights: A new reset type charge sensitive amplifier for gamma-ray spectrometer based on a photomultiplier tube is proposed. Reset circuit formed by constant current source output a fixed width pulse to reset charge sensitive amplifier. Photomultiplier tube dark current compensation circuit could increase the pulse through rate by decreasing reset frequency. This amplifier outputs a step function signal that could match next stage circuit easily. … (more)
- Is Part Of:
- Applied radiation and isotopes. Volume 97(2015:Mar.)
- Journal:
- Applied radiation and isotopes
- Issue:
- Volume 97(2015:Mar.)
- Issue Display:
- Volume 97 (2015)
- Year:
- 2015
- Volume:
- 97
- Issue Sort Value:
- 2015-0097-0000-0000
- Page Start:
- 63
- Page End:
- 69
- Publication Date:
- 2015-03
- Subjects:
- NaI(Tl) gamma-ray spectrometer -- Photomultiplier tube (PMT) -- Reset charge sensitive amplifier (RCSA) -- Equivalent noise charge (ENC)
Radiology -- Periodicals
Radiation -- Industrial applications -- Periodicals
Nuclear chemistry -- Periodicals
Internet resource
Periodical
660.298 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09698043 ↗
http://catalog.hathitrust.org/api/volumes/oclc/27456684.html ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apradiso.2014.12.009 ↗
- Languages:
- English
- ISSNs:
- 0969-8043
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1576.565000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9022.xml