Gait characterization for osteoarthritis patients using wearable gait sensors (H-Gait systems). Issue 5 (21st March 2016)
- Record Type:
- Journal Article
- Title:
- Gait characterization for osteoarthritis patients using wearable gait sensors (H-Gait systems). Issue 5 (21st March 2016)
- Main Title:
- Gait characterization for osteoarthritis patients using wearable gait sensors (H-Gait systems)
- Authors:
- Tadano, Shigeru
Takeda, Ryo
Sasaki, Keita
Fujisawa, Tadashi
Tohyama, Harukazu - Abstract:
- Abstract: The objective of this work was to investigate the possibilities of using the wearable sensors-based H-Gait system in an actual clinical trial and proposes new gait parameters for characterizing OA gait. Seven H-Gait sensors, consisting of tri-axial inertial sensors, were attached to seven lower limb body segments (pelvis, both thighs, both shanks and both feet). The acceleration and angular velocity data measured were used to estimate three-dimensional kinematic parameters of patients during level walking. Three new parameters were proposed to assess the severity of OA based on the characteristics of these joint center trajectories in addition to conventional gait spatio-temporal parameters. The experiment was conducted on ten subjects with knee OA. The kinematic results obtained (hip, knee and ankle joint angles, joint trajectory in the horizontal and sagittal planes) were compared with those from a reference healthy (control) group. As a result, the angle between the right and left knee trajectories along with that of the ankle joint trajectories were almost twice as large (21.3° vs. 11.6° and 14.9° vs. 7.8°) compared to those of the healthy subjects. In conclusion, it was found that the ankle joints during stance abduct less to avoid adduction at the knee as the severity of OA increases and lead to more acute angles (less parallel) between the right and left knee/ankle joints in the horizontal plane. This method was capable to provide quantitative informationAbstract: The objective of this work was to investigate the possibilities of using the wearable sensors-based H-Gait system in an actual clinical trial and proposes new gait parameters for characterizing OA gait. Seven H-Gait sensors, consisting of tri-axial inertial sensors, were attached to seven lower limb body segments (pelvis, both thighs, both shanks and both feet). The acceleration and angular velocity data measured were used to estimate three-dimensional kinematic parameters of patients during level walking. Three new parameters were proposed to assess the severity of OA based on the characteristics of these joint center trajectories in addition to conventional gait spatio-temporal parameters. The experiment was conducted on ten subjects with knee OA. The kinematic results obtained (hip, knee and ankle joint angles, joint trajectory in the horizontal and sagittal planes) were compared with those from a reference healthy (control) group. As a result, the angle between the right and left knee trajectories along with that of the ankle joint trajectories were almost twice as large (21.3° vs. 11.6° and 14.9° vs. 7.8°) compared to those of the healthy subjects. In conclusion, it was found that the ankle joints during stance abduct less to avoid adduction at the knee as the severity of OA increases and lead to more acute angles (less parallel) between the right and left knee/ankle joints in the horizontal plane. This method was capable to provide quantitative information about the gait of OA patients and has the advantage to allow for out-of-laboratory monitoring. … (more)
- Is Part Of:
- Journal of biomechanics. Volume 49:Issue 5(2016)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 49:Issue 5(2016)
- Issue Display:
- Volume 49, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 49
- Issue:
- 5
- Issue Sort Value:
- 2016-0049-0005-0000
- Page Start:
- 684
- Page End:
- 690
- Publication Date:
- 2016-03-21
- Subjects:
- Osteoarthritis -- Three dimensional gait analysis -- Acceleration sensor -- Gyro sensor -- Kinematic gait parameters -- Spatio-temporal gait parameters
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2016.01.017 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9020.xml