A study on the performance characteristics of a testing facility for a water-to-water heat pump. (February 2018)
- Record Type:
- Journal Article
- Title:
- A study on the performance characteristics of a testing facility for a water-to-water heat pump. (February 2018)
- Main Title:
- A study on the performance characteristics of a testing facility for a water-to-water heat pump
- Authors:
- Amoabeng, Kofi Owura
Lee, Kwang Ho
Choi, Jong Min - Abstract:
- Highlights: The performance characteristics of a water-to-water heat pump test facility were investigated. Experiments were performed with the variation in capacity and COP of heat pump. The study was conducted in both heating and cooling operating modes of heat pump unit. The energy consumption of the water-to-water heat pump test facility was analyzed. Abstract: Heat pump testing facility is used to investigate the performance and reliability of a heat pump unit. During the testing period, energy is utilized by the facility mainly through cooling with a refrigeration unit and heating with an electric heater to control and maintain the test conditions of the heat pump unit. However, research study on the energy consumption analysis of the heat pump test facility is rarely found in literature. In this study, the performance characteristics of the testing facility for a water-to-water heat pump are investigated according to the variation of heat pump capacity and COP in both cooling and heating operating modes. The objective is to analyze the energy consumption of the test facility used to investigate the performance of a water-to-water heat pump unit. The analysis of experimental test results showed that the total energy consumption rate of the heat pump test facility increased as capacity and COP of heat pump increased in both cooling and heating modes. However, the increment according to COP variation was smaller than capacity variation. Also, the total energy consumptionHighlights: The performance characteristics of a water-to-water heat pump test facility were investigated. Experiments were performed with the variation in capacity and COP of heat pump. The study was conducted in both heating and cooling operating modes of heat pump unit. The energy consumption of the water-to-water heat pump test facility was analyzed. Abstract: Heat pump testing facility is used to investigate the performance and reliability of a heat pump unit. During the testing period, energy is utilized by the facility mainly through cooling with a refrigeration unit and heating with an electric heater to control and maintain the test conditions of the heat pump unit. However, research study on the energy consumption analysis of the heat pump test facility is rarely found in literature. In this study, the performance characteristics of the testing facility for a water-to-water heat pump are investigated according to the variation of heat pump capacity and COP in both cooling and heating operating modes. The objective is to analyze the energy consumption of the test facility used to investigate the performance of a water-to-water heat pump unit. The analysis of experimental test results showed that the total energy consumption rate of the heat pump test facility increased as capacity and COP of heat pump increased in both cooling and heating modes. However, the increment according to COP variation was smaller than capacity variation. Also, the total energy consumption rate of the testing facility was about ten times more than the energy consumption rate of the heat pump unit. … (more)
- Is Part Of:
- International journal of refrigeration. Volume 86(2018)
- Journal:
- International journal of refrigeration
- Issue:
- Volume 86(2018)
- Issue Display:
- Volume 86, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 86
- Issue:
- 2018
- Issue Sort Value:
- 2018-0086-2018-0000
- Page Start:
- 113
- Page End:
- 126
- Publication Date:
- 2018-02
- Subjects:
- Test facility -- Test standard -- Heat pump -- Operating mode -- Energy consumption
Installation d'essai -- Norme d'essai -- Pompe à chaleur -- Mode de fonctionnement -- Consommation énergétique
Refrigeration and refrigerating machinery -- Periodicals
621.56 - Journal URLs:
- http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science/journal/aip/01407007 ↗ - DOI:
- 10.1016/j.ijrefrig.2017.11.013 ↗
- Languages:
- English
- ISSNs:
- 0140-7007
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.525500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9010.xml