40 Hz auditory steady-state response in schizophrenia: Sensitivity to stimulation type (clicks versus flutter amplitude-modulated tones). (1st January 2018)
- Record Type:
- Journal Article
- Title:
- 40 Hz auditory steady-state response in schizophrenia: Sensitivity to stimulation type (clicks versus flutter amplitude-modulated tones). (1st January 2018)
- Main Title:
- 40 Hz auditory steady-state response in schizophrenia: Sensitivity to stimulation type (clicks versus flutter amplitude-modulated tones)
- Authors:
- Griskova-Bulanova, Inga
Dapsys, Kastytis
Melynyte, Sigita
Voicikas, Aleksandras
Maciulis, Valentinas
Andruskevicius, Sergejus
Korostenskaja, Milena - Abstract:
- Highlights: 40 Hz ASSRs were elicited by flutter amplitude-modulated tones and clicks. Responses were compared between schizophrenia patients and controls. An early-latency gamma of 40 Hz ASSR was reduced in patients to clicks only. A late-latency gamma of 40 Hz ASSR was reduced to both stimulation types in patients. 40 Hz ASSR parameters to both stimulation types did not correlate in patients. Abstract: Auditory steady-state response (ASSR) at 40 Hz has been proposed as a potential biomarker for schizophrenia. The ASSR studies in patients have used click stimulation or amplitude-modulated tones. However, the sensitivity of 40 Hz ASSRs to different stimulation types in the same group of patients has not been previously evaluated. Two stimulation types for ASSRs were tested in this study: (1) 40 Hz clicks and (2) flutter-amplitude modulated tones. The mean phase-locking index, evoked amplitude and event-related spectral perturbation values were compared between schizophrenia patients (n = 26) and healthy controls (n = 20). Both stimulation types resulted in the observation of impaired phase-locking and power measures of late (200–500 ms) 40 Hz ASSR in patients compared to healthy controls. The early-latency (0–100 ms) 40 Hz ASSR part was diminished in the schizophrenia group in response to clicks only. The late-latency 40 Hz ASSR parameters obtained through different stimulation types correlated in healthy subjects but not in patients. We conclude that flutterHighlights: 40 Hz ASSRs were elicited by flutter amplitude-modulated tones and clicks. Responses were compared between schizophrenia patients and controls. An early-latency gamma of 40 Hz ASSR was reduced in patients to clicks only. A late-latency gamma of 40 Hz ASSR was reduced to both stimulation types in patients. 40 Hz ASSR parameters to both stimulation types did not correlate in patients. Abstract: Auditory steady-state response (ASSR) at 40 Hz has been proposed as a potential biomarker for schizophrenia. The ASSR studies in patients have used click stimulation or amplitude-modulated tones. However, the sensitivity of 40 Hz ASSRs to different stimulation types in the same group of patients has not been previously evaluated. Two stimulation types for ASSRs were tested in this study: (1) 40 Hz clicks and (2) flutter-amplitude modulated tones. The mean phase-locking index, evoked amplitude and event-related spectral perturbation values were compared between schizophrenia patients (n = 26) and healthy controls (n = 20). Both stimulation types resulted in the observation of impaired phase-locking and power measures of late (200–500 ms) 40 Hz ASSR in patients compared to healthy controls. The early-latency (0–100 ms) 40 Hz ASSR part was diminished in the schizophrenia group in response to clicks only. The late-latency 40 Hz ASSR parameters obtained through different stimulation types correlated in healthy subjects but not in patients. We conclude that flutter amplitude-modulated tone stimulation, due to its potential to reveal late-latency entrainment deficits, is suitable for use in clinical populations. Careful consideration of experimental stimulation settings can contribute to the interpretation of ASSR deficits and utilization as a potential biomarker. … (more)
- Is Part Of:
- Neuroscience letters. Volume 662(2018)
- Journal:
- Neuroscience letters
- Issue:
- Volume 662(2018)
- Issue Display:
- Volume 662, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 662
- Issue:
- 2018
- Issue Sort Value:
- 2018-0662-2018-0000
- Page Start:
- 152
- Page End:
- 157
- Publication Date:
- 2018-01-01
- Subjects:
- Auditory steady-state response -- ASSR -- Gamma activity -- Flutter amplitude-modulated tone -- FAM -- Schizophrenia biomarker
Neurology -- Periodicals
Neurology -- Periodicals
Research -- Periodicals
Neurologie -- Périodiques
Neuroanatomie -- Périodiques
Neuropharmacologie -- Périodiques
Neurophysiologie -- Périodiques
Neurology
Periodicals
Electronic journals
617.48 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03043940 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.neulet.2017.10.025 ↗
- Languages:
- English
- ISSNs:
- 0304-3940
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.562000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9027.xml