Combining High-Sensitivity Cardiac Troponin I and Cardiac Troponin T in the Early Diagnosis of Acute Myocardial Infarction. Issue 10 (4th September 2018)
- Record Type:
- Journal Article
- Title:
- Combining High-Sensitivity Cardiac Troponin I and Cardiac Troponin T in the Early Diagnosis of Acute Myocardial Infarction. Issue 10 (4th September 2018)
- Main Title:
- Combining High-Sensitivity Cardiac Troponin I and Cardiac Troponin T in the Early Diagnosis of Acute Myocardial Infarction
- Authors:
- van der Linden, Noreen
Wildi, Karin
Twerenbold, Raphael
Pickering, John W.
Than, Martin
Cullen, Louise
Greenslade, Jaimi
Parsonage, William
Nestelberger, Thomas
Boeddinghaus, Jasper
Badertscher, Patrick
Rubini Giménez, Maria
Klinkenberg, Lieke J.J.
Bekers, Otto
Schöni, Aline
Keller, Dagmar I.
Sabti, Zaid
Puelacher, Christian
Cupa, Janosch
Schumacher, Lukas
Kozhuharov, Nikola
Grimm, Karin
Shrestha, Samyut
Flores, Dayana
Freese, Michael
Stelzig, Claudia
Strebel, Ivo
Miró, Òscar
Rentsch, Katharina
Morawiec, Beata
Kawecki, Damian
Kloos, Wanda
Lohrmann, Jens
Richards, A. Mark
Troughton, Richard
Pemberton, Christopher
Osswald, Stefan
van Dieijen-Visser, Marja P.
Mingels, Alma M.
Reichlin, Tobias
Meex, Steven J.R.
Mueller, Christian
… (more) - Abstract:
- Abstract : Background: Combining 2 signals of cardiomyocyte injury, cardiac troponin I (cTnI) and T (cTnT), might overcome some individual pathophysiological and analytical limitations and thereby increase diagnostic accuracy for acute myocardial infarction with a single blood draw. We aimed to evaluate the diagnostic performance of combinations of high-sensitivity (hs) cTnI and hs-cTnT for the early diagnosis of acute myocardial infarction. Methods: The diagnostic performance of combining hs-cTnI (Architect, Abbott) and hs-cTnT (Elecsys, Roche) concentrations (sum, product, ratio, and a combination algorithm) obtained at the time of presentation was evaluated in a large multicenter diagnostic study of patients with suspected acute myocardial infarction. The optimal rule-out and rule-in thresholds were externally validated in a second large multicenter diagnostic study. The proportion of patients eligible for early rule-out was compared with the European Society of Cardiology 0/1 and 0/3 hour algorithms. Results: Combining hs-cTnI and hs-cTnT concentrations did not consistently increase overall diagnostic accuracy as compared with the individual isoforms. However, the combination improved the proportion of patients meeting criteria for very early rule-out. With the European Society of Cardiology 2015 guideline recommended algorithms and cut-offs, the proportion meeting rule-out criteria after the baseline blood sampling was limited (6% to 24%) and assay dependent.Abstract : Background: Combining 2 signals of cardiomyocyte injury, cardiac troponin I (cTnI) and T (cTnT), might overcome some individual pathophysiological and analytical limitations and thereby increase diagnostic accuracy for acute myocardial infarction with a single blood draw. We aimed to evaluate the diagnostic performance of combinations of high-sensitivity (hs) cTnI and hs-cTnT for the early diagnosis of acute myocardial infarction. Methods: The diagnostic performance of combining hs-cTnI (Architect, Abbott) and hs-cTnT (Elecsys, Roche) concentrations (sum, product, ratio, and a combination algorithm) obtained at the time of presentation was evaluated in a large multicenter diagnostic study of patients with suspected acute myocardial infarction. The optimal rule-out and rule-in thresholds were externally validated in a second large multicenter diagnostic study. The proportion of patients eligible for early rule-out was compared with the European Society of Cardiology 0/1 and 0/3 hour algorithms. Results: Combining hs-cTnI and hs-cTnT concentrations did not consistently increase overall diagnostic accuracy as compared with the individual isoforms. However, the combination improved the proportion of patients meeting criteria for very early rule-out. With the European Society of Cardiology 2015 guideline recommended algorithms and cut-offs, the proportion meeting rule-out criteria after the baseline blood sampling was limited (6% to 24%) and assay dependent. Application of optimized cut-off values using the sum (9 ng/L) and product (18 ng 2 /L 2 ) of hs-cTnI and hs-cTnT concentrations led to an increase in the proportion ruled-out after a single blood draw to 34% to 41% in the original (sum: negative predictive value [NPV] 100% [95% confidence interval (CI), 99.5% to 100%]; product: NPV 100% [95% CI, 99.5% to 100%]) and in the validation cohort (sum: NPV 99.6% [95% CI, 99.0–99.9%]; product: NPV 99.4% [95% CI, 98.8–99.8%]). The use of a combination algorithm (hs-cTnI <4 ng/L and hs-cTnT <9 ng/L) showed comparable results for rule-out (40% to 43% ruled out; NPV original cohort 99.9% [95% CI, 99.2–100%]; NPV validation cohort 99.5% [95% CI, 98.9–99.8%]) and rule-in (positive predictive value [PPV] original cohort 74.4% [95% Cl, 69.6–78.8%]; PPV validation cohort 84.0% [95% Cl, 79.7–87.6%]). Conclusions: New strategies combining hs-cTnI and hs-cTnT concentrations may significantly increase the number of patients eligible for very early and safe rule-out, but do not seem helpful for the rule-in of acute myocardial infarction. Clinical Trial Registration: URL (APACE):https://www.clinicaltrial.gov . Unique identifier: NCT00470587. URL (ADAPT):www.anzctr.org.au . Unique identifier: ACTRN12611001069943. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 138:Issue 10(2018)
- Journal:
- Circulation
- Issue:
- Volume 138:Issue 10(2018)
- Issue Display:
- Volume 138, Issue 10 (2018)
- Year:
- 2018
- Volume:
- 138
- Issue:
- 10
- Issue Sort Value:
- 2018-0138-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-09-04
- Subjects:
- combination -- diagnosis -- myocardial infarction -- troponins
Blood -- Circulation -- Periodicals
Cardiovascular system -- Periodicals
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
Blood Circulation
Cardiovascular System
Vascular Diseases
616.1 - Journal URLs:
- http://ovidsp.tx.ovid.com/sp-3.4.2a/ovidweb.cgi?&S=HFFJFPCLPODDKOLGNCALDCMCIACKAA00&Browse=Toc+Children%7cNO%7cS.sh.1384_1326796138_84.1384_1326796138_96.1384_1326796138_97%7c66%7c50 ↗
http://www.circulationaha.org ↗
http://circ.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCULATIONAHA.117.032003 ↗
- Languages:
- English
- ISSNs:
- 0009-7322
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9006.xml