Plate fixation through an anterior approach for coronoid process fractures: A retrospective case series and a literature review. Issue 36 (September 2018)
- Record Type:
- Journal Article
- Title:
- Plate fixation through an anterior approach for coronoid process fractures: A retrospective case series and a literature review. Issue 36 (September 2018)
- Main Title:
- Plate fixation through an anterior approach for coronoid process fractures
- Authors:
- Feng, Dongxu
Zhang, Xin
Jiang, Yonghong
Zhu, Yangjun
Wang, Hao
Wu, Shufang
Zhang, Kun
Wang, Zhan
Zhang, Jun - Other Names:
- Phan. Phil section editor.
- Abstract:
- Abstract : Abstract: Coronoid process fractures of the ulna are difficult to treat, and are associated with stiffness, recurrent instability, and pain. Hence, treatment of coronoid process fractures are challenging for surgeons. The purpose of this study was to report the clinical outcomes of an anterior surgical approach associated with plate fixation for Regan and Morrey type II or type III fractures of the coronoid process. We evaluated 16 consecutive patients who underwent surgical treatment for fracture of the coronoid process of the ulna from March 2012 to July 2016. Ten patients had a type II fracture, and 6 patients had a type III fracture. All patients underwent surgical treatment for coronoid process fracture through an anterior approach. While preserving the neurovascular structure, all fractures were treated with buttress plate fixation, maintaining the gap between brachial artery and median nerve. Each patient was treated with concentric reduction of both the ulnotrochlear and the radiocapitellar articulations, without any evidence of elbow instability, except 1 case, who showed some medial instability. At the final follow-up, solid osseous union was confirmed for all coronoid fractures. The average time to radiologic union was 16.3 weeks. The mean flexion–extension arc was 124.25 ± 12.12 degree, with a mean flexion contracture of 8.25 ± 4.36 degree, and further flexion of 132.5 ± 9.31 degree. The mean forearm rotation arc was 167.81 ± 10.49 degree. FifteenAbstract : Abstract: Coronoid process fractures of the ulna are difficult to treat, and are associated with stiffness, recurrent instability, and pain. Hence, treatment of coronoid process fractures are challenging for surgeons. The purpose of this study was to report the clinical outcomes of an anterior surgical approach associated with plate fixation for Regan and Morrey type II or type III fractures of the coronoid process. We evaluated 16 consecutive patients who underwent surgical treatment for fracture of the coronoid process of the ulna from March 2012 to July 2016. Ten patients had a type II fracture, and 6 patients had a type III fracture. All patients underwent surgical treatment for coronoid process fracture through an anterior approach. While preserving the neurovascular structure, all fractures were treated with buttress plate fixation, maintaining the gap between brachial artery and median nerve. Each patient was treated with concentric reduction of both the ulnotrochlear and the radiocapitellar articulations, without any evidence of elbow instability, except 1 case, who showed some medial instability. At the final follow-up, solid osseous union was confirmed for all coronoid fractures. The average time to radiologic union was 16.3 weeks. The mean flexion–extension arc was 124.25 ± 12.12 degree, with a mean flexion contracture of 8.25 ± 4.36 degree, and further flexion of 132.5 ± 9.31 degree. The mean forearm rotation arc was 167.81 ± 10.49 degree. Fifteen patients achieved a functional arc of motion. The mean Mayo elbow performance score was 92.1 points, with 12 excellent cases and 4 good cases. Coronoid process fractures of the ulna can be treated successfully with plate fixation through an anterior surgical approach, which allows for accurate reduction and rigid internal fixation and early functional exercise, resulting in a reasonable outcome. … (more)
- Is Part Of:
- Medicine. Volume 97:Issue 36(2018)
- Journal:
- Medicine
- Issue:
- Volume 97:Issue 36(2018)
- Issue Display:
- Volume 97, Issue 36 (2018)
- Year:
- 2018
- Volume:
- 97
- Issue:
- 36
- Issue Sort Value:
- 2018-0097-0036-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-09
- Subjects:
- anterior approach -- coronoid process -- fracture -- plate fixation -- the terrible triad of the elbow -- treatment
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000012041 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9000.xml