Influence of channel configuration on bandwidth of cadmium zinc telluride detector with a cross-strip pattern. (February 2019)
- Record Type:
- Journal Article
- Title:
- Influence of channel configuration on bandwidth of cadmium zinc telluride detector with a cross-strip pattern. (February 2019)
- Main Title:
- Influence of channel configuration on bandwidth of cadmium zinc telluride detector with a cross-strip pattern
- Authors:
- Li, Mohan
Abbaszadeh, Shiva - Abstract:
- Abstract: The detector readout bandwidth is of paramount importance to achieve a high count rate and thus a high sensitivity. For detectors with the number of readout channels larger than that of the application-specific integrated circuit (ASIC), multiple ASICs are required. In systems with such a readout scheme, it is important to consider the load balance to achieve the highest count rate. In this work, a Monte Carlo simulation was performed to investigate the bandwidths of different load balancing configurations between two ASICs in a cross-strip cadmium zinc telluride detector. It is found that for anode strips, allocating each ASIC to half of the detector area provides a higher bandwidth when compared to allocating ASIC channels to alternate anode channels. Cathodes that are closer to the field of view will trigger more often and require a more complex load balancing scheme. Charge sharing and scattering play a role in the different bandwidths, and the bandwidth of the half-half configuration is 2.82% higher than that of the alternate configuration. Abstract : Highlights: The load balance of ASICs affects the readout bandwidth of CZT detector. Charge sharing and scattering play a role in the achieved bandwidth. For anodes, the bandwidth of the half-half configuration improves 2.82%. Cathodes need calibration to allocate balanced load to different ASICs.
- Is Part Of:
- Radiation physics and chemistry. Volume 155(2019:Feb.)
- Journal:
- Radiation physics and chemistry
- Issue:
- Volume 155(2019:Feb.)
- Issue Display:
- Volume 155 (2019)
- Year:
- 2019
- Volume:
- 155
- Issue Sort Value:
- 2019-0155-0000-0000
- Page Start:
- 213
- Page End:
- 216
- Publication Date:
- 2019-02
- Subjects:
- Cadmium zinc telluride -- Cross-strip pattern -- Channel configuration -- Application-specific integrated circuit -- Bandwidth
Radiation chemistry -- Periodicals
Radiometry -- Periodicals
Radiation -- Periodicals
Chimie sous rayonnement -- Périodiques
539.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0969806X ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-physics-and-chemistry/ ↗ - DOI:
- 10.1016/j.radphyschem.2018.04.015 ↗
- Languages:
- English
- ISSNs:
- 0969-806X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.984000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8999.xml