Evaluation of a portable low-budget three-dimensional stereophotogrammetry system for nasal analysis. Issue 12 (December 2018)
- Record Type:
- Journal Article
- Title:
- Evaluation of a portable low-budget three-dimensional stereophotogrammetry system for nasal analysis. Issue 12 (December 2018)
- Main Title:
- Evaluation of a portable low-budget three-dimensional stereophotogrammetry system for nasal analysis
- Authors:
- Ritschl, Lucas M.
Grill, Florian D.
Mittermeier, Fabienna
Lonic, Daniel
Wolff, Klaus-Dietrich
Roth, Maximilian
Loeffelbein, Denys J. - Abstract:
- Abstract: Background: Three-dimensional (3D) photogrammetry has reached high standards and accuracy but is mainly conducted with stationary and expensive systems. The purpose of this study was to evaluate the accuracy of a low-budget portable system with special regard to the gracile and challenging nasal region. Material and Methods: 3D models of the perinasal area were acquired by impression-taking and the scanning of the generated plaster models (3Shape D500) or with a portable low-budget 3D stereophotogrammetry (FUEL3D ® SCANIFY ® ) system. Four examiners analysed defined landmarks of the generated Standard Tessellation Language files with regard to accuracy and interobserver reliability by using 3dMDvultus™ software. A semi-automatic 3D best-fit analysis of both models was performed by using Geomagic ® and the Root Mean Squared (RMS) errors were calculated. Results: 41 volunteers were included, with 22 perinasal and perioral landmarks, 15 3D distances and eight 3D angles being analysed per data set. In a point-based analysis the mean spreads were partially smaller in the plaster model scans. Most measurements showed very high (>0.8) to excellent (>0.9) intraclass correlation coefficients, the lowest being found for columella length (0.686) and left nostril width (0.636). Overall, the mean RMS error between the superimposed surfaces was 0.89 ± 0.22 mm in the best-fit analysis. Conclusions: The corresponding software program was operator-friendly. The findings indicateAbstract: Background: Three-dimensional (3D) photogrammetry has reached high standards and accuracy but is mainly conducted with stationary and expensive systems. The purpose of this study was to evaluate the accuracy of a low-budget portable system with special regard to the gracile and challenging nasal region. Material and Methods: 3D models of the perinasal area were acquired by impression-taking and the scanning of the generated plaster models (3Shape D500) or with a portable low-budget 3D stereophotogrammetry (FUEL3D ® SCANIFY ® ) system. Four examiners analysed defined landmarks of the generated Standard Tessellation Language files with regard to accuracy and interobserver reliability by using 3dMDvultus™ software. A semi-automatic 3D best-fit analysis of both models was performed by using Geomagic ® and the Root Mean Squared (RMS) errors were calculated. Results: 41 volunteers were included, with 22 perinasal and perioral landmarks, 15 3D distances and eight 3D angles being analysed per data set. In a point-based analysis the mean spreads were partially smaller in the plaster model scans. Most measurements showed very high (>0.8) to excellent (>0.9) intraclass correlation coefficients, the lowest being found for columella length (0.686) and left nostril width (0.636). Overall, the mean RMS error between the superimposed surfaces was 0.89 ± 0.22 mm in the best-fit analysis. Conclusions: The corresponding software program was operator-friendly. The findings indicate that the analysed, affordable and portable system is a feasible solution for 3D image acquisition with comparable accuracy reported in the literature. Further studies will analyse the feasibility in neonates. … (more)
- Is Part Of:
- Journal of cranio-maxillofacial surgery. Volume 46:Issue 12(2018)
- Journal:
- Journal of cranio-maxillofacial surgery
- Issue:
- Volume 46:Issue 12(2018)
- Issue Display:
- Volume 46, Issue 12 (2018)
- Year:
- 2018
- Volume:
- 46
- Issue:
- 12
- Issue Sort Value:
- 2018-0046-0012-0000
- Page Start:
- 2008
- Page End:
- 2016
- Publication Date:
- 2018-12
- Subjects:
- Three-dimensional stereophotogrammetry -- Nose -- CAD/CAM nasoalveolar molding -- Portable facial scanner
Skull -- Surgery -- Periodicals
Maxilla -- Surgery -- Periodicals
Face -- Surgery -- Periodicals
Surgery, Plastic -- Periodicals
Maxilla -- surgery -- Periodicals
Face -- surgery -- Periodicals
Skull -- surgery -- Periodicals
Oral Surgical Procedures -- Periodicals
Reconstructive Surgical Procedures -- Periodicals
Surgery, Plastic -- Periodicals
Surgery, Oral -- Periodicals
Electronic journals
617.514 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10105182 ↗
http://firstsearch.oclc.org ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10105182 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jcms.2018.04.025 ↗
- Languages:
- English
- ISSNs:
- 1010-5182
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4965.482000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9000.xml