Measurement of mass flow rate and evaluation of heat transfer coefficient for high-pressure pneumatic components during charge and discharge processes. (October 2015)
- Record Type:
- Journal Article
- Title:
- Measurement of mass flow rate and evaluation of heat transfer coefficient for high-pressure pneumatic components during charge and discharge processes. (October 2015)
- Main Title:
- Measurement of mass flow rate and evaluation of heat transfer coefficient for high-pressure pneumatic components during charge and discharge processes
- Authors:
- Gao, Longlong
Yang, Gang
Li, Weijia
Li, Baoren - Abstract:
- Abstract: Both the mass flow rate and heat transfer characteristics are significant factors to the flow behavior of the high-pressure air; however, they are not easy to be obtained by analytical model during discharge and charge processes. In this paper, the mass flow rate characteristics of high-pressure pneumatic components (HPPC) are measured by a compounding approach; two components under test with the same geometry and dimension are needed to be connected in series. Both the effective cross-section area and critical pressure ratio of HPPC are determined accurately, and only the pressure variation and the steady-state temperature of air in the chamber are utilized. The compared results between experimental and simulation data show that the accuracy of the measured effective cross-section area and critical pressure ratio of the HPPC is high when the sonic and adiabatic releasing time is less than 2 s. And then, a new combined method of calculating the heat transfer coefficient during discharging and charging processes for the high-pressure air is proposed. The computational fluid dynamics (CFD) method is used to illustrate the intensity of heat exchange between the high-pressure air inside the chamber and outer atmosphere. The dynamic flow behavior is analyzed based on the tested flow rate characteristics of HPPC, mixed heat transfer theory and numerical results. The results show that the heat-transfer coefficient during charge process is much greater than dischargeAbstract: Both the mass flow rate and heat transfer characteristics are significant factors to the flow behavior of the high-pressure air; however, they are not easy to be obtained by analytical model during discharge and charge processes. In this paper, the mass flow rate characteristics of high-pressure pneumatic components (HPPC) are measured by a compounding approach; two components under test with the same geometry and dimension are needed to be connected in series. Both the effective cross-section area and critical pressure ratio of HPPC are determined accurately, and only the pressure variation and the steady-state temperature of air in the chamber are utilized. The compared results between experimental and simulation data show that the accuracy of the measured effective cross-section area and critical pressure ratio of the HPPC is high when the sonic and adiabatic releasing time is less than 2 s. And then, a new combined method of calculating the heat transfer coefficient during discharging and charging processes for the high-pressure air is proposed. The computational fluid dynamics (CFD) method is used to illustrate the intensity of heat exchange between the high-pressure air inside the chamber and outer atmosphere. The dynamic flow behavior is analyzed based on the tested flow rate characteristics of HPPC, mixed heat transfer theory and numerical results. The results show that the heat-transfer coefficient during charge process is much greater than discharge process, and the forced convection heat exchange happened owing to the strong "air agitation" during the charge process. The experimental results also validate that the proposed method of calculating the transient heat transfer coefficient is more reasonable to describe the heat transfer behavior. The findings may also have general implication in the development of the design and analysis of the high-pressure pneumatic system. Highlights: The mass flow rate characteristics of high-pressure components are measured. The effective cross area and critical pressure ratio are accurately determined. A new combined method of calculating heat transfer coefficient is proposed. The heat transfer coefficient during charge process is larger than discharge. The higher the supply pressure is, the larger the heat transfer coefficient is. … (more)
- Is Part Of:
- Flow measurement and instrumentation. Volume 45(2015:Oct.)
- Journal:
- Flow measurement and instrumentation
- Issue:
- Volume 45(2015:Oct.)
- Issue Display:
- Volume 45 (2015)
- Year:
- 2015
- Volume:
- 45
- Issue Sort Value:
- 2015-0045-0000-0000
- Page Start:
- 391
- Page End:
- 403
- Publication Date:
- 2015-10
- Subjects:
- Flow rate characteristics -- Effective cross-section area -- Critical pressure ratio -- Heat-transfer coefficient -- Computational fluid dynamics
Fluid dynamic measurements -- Periodicals
Flow meters -- Periodicals
Fluides, Dynamique des -- Mesure -- Périodiques
Débitmètres -- Périodiques
681.2805 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09555986 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.flowmeasinst.2015.08.006 ↗
- Languages:
- English
- ISSNs:
- 0955-5986
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3958.300000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8996.xml