B0 concomitant field compensation for MRI systems employing asymmetric transverse gradient coils. Issue 3 (21st June 2017)
- Record Type:
- Journal Article
- Title:
- B0 concomitant field compensation for MRI systems employing asymmetric transverse gradient coils. Issue 3 (21st June 2017)
- Main Title:
- B0 concomitant field compensation for MRI systems employing asymmetric transverse gradient coils
- Authors:
- Weavers, Paul T.
Tao, Shengzhen
Trzasko, Joshua D.
Frigo, Louis M.
Shu, Yunhong
Frick, Matthew A.
Lee, Seung‐Kyun
Foo, Thomas K‐F
Bernstein, Matt A. - Abstract:
- Abstract : Purpose: Imaging gradients result in the generation of concomitant fields, or Maxwell fields, which are of increasing importance at higher gradient amplitudes. These time‐varying fields cause additional phase accumulation, which must be compensated for to avoid image artifacts. In the case of gradient systems employing symmetric design, the concomitant fields are well described with second‐order spatial variation. Gradient systems employing asymmetric design additionally generate concomitant fields with global (zeroth‐order or B0 ) and linear (first‐order) spatial dependence. Methods: This work demonstrates a general solution to eliminate the zeroth‐order concomitant field by applying the correct B0 frequency shift in real time to counteract the concomitant fields. Results are demonstrated for phase contrast, spiral, echo‐planar imaging (EPI), and fast spin‐echo imaging. Results: A global phase offset is reduced in the phase‐contrast exam, and blurring is virtually eliminated in spiral images. The bulk image shift in the phase‐encode direction is compensated for in EPI, whereas signal loss, ghosting, and blurring are corrected in the fast‐spin echo images. Conclusion: A user‐transparent method to compensate the zeroth‐order concomitant field term by center frequency shifting is proposed and implemented. This solution allows all the existing pulse sequences—both product and research—to be retained without any modifications. Magn Reson Med 79:1538–1544, 2018. © 2017Abstract : Purpose: Imaging gradients result in the generation of concomitant fields, or Maxwell fields, which are of increasing importance at higher gradient amplitudes. These time‐varying fields cause additional phase accumulation, which must be compensated for to avoid image artifacts. In the case of gradient systems employing symmetric design, the concomitant fields are well described with second‐order spatial variation. Gradient systems employing asymmetric design additionally generate concomitant fields with global (zeroth‐order or B0 ) and linear (first‐order) spatial dependence. Methods: This work demonstrates a general solution to eliminate the zeroth‐order concomitant field by applying the correct B0 frequency shift in real time to counteract the concomitant fields. Results are demonstrated for phase contrast, spiral, echo‐planar imaging (EPI), and fast spin‐echo imaging. Results: A global phase offset is reduced in the phase‐contrast exam, and blurring is virtually eliminated in spiral images. The bulk image shift in the phase‐encode direction is compensated for in EPI, whereas signal loss, ghosting, and blurring are corrected in the fast‐spin echo images. Conclusion: A user‐transparent method to compensate the zeroth‐order concomitant field term by center frequency shifting is proposed and implemented. This solution allows all the existing pulse sequences—both product and research—to be retained without any modifications. Magn Reson Med 79:1538–1544, 2018. © 2017 International Society for Magnetic Resonance in Medicine. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 79:Issue 3(2018)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 79:Issue 3(2018)
- Issue Display:
- Volume 79, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 79
- Issue:
- 3
- Issue Sort Value:
- 2018-0079-0003-0000
- Page Start:
- 1538
- Page End:
- 1544
- Publication Date:
- 2017-06-21
- Subjects:
- B0 -- asymmetric gradients -- real‐time correction -- frequency shifting
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26790 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8977.xml