Impact of prior distributions and central tendency measures on Bayesian intravoxel incoherent motion model fitting. Issue 3 (19th June 2017)
- Record Type:
- Journal Article
- Title:
- Impact of prior distributions and central tendency measures on Bayesian intravoxel incoherent motion model fitting. Issue 3 (19th June 2017)
- Main Title:
- Impact of prior distributions and central tendency measures on Bayesian intravoxel incoherent motion model fitting
- Authors:
- Gustafsson, Oscar
Montelius, Mikael
Starck, Göran
Ljungberg, Maria - Abstract:
- Abstract : Purpose: Bayesian model fitting has been proposed as a robust alternative for intravoxel incoherent motion (IVIM) model‐fitting parameter estimation. However, consensus regarding choice of prior distribution and posterior distribution central tendency measure is needed. The aim of this study was to compare the quality of IVIM parameter estimates produced by different prior distributions and central tendency measures, and to gain knowledge about the effect of these choices. Methods: Three prior distributions (uniform, reciprocal, and lognormal) and two measures of central tendency (mean and mode) found in the literature were studied using simulations and in vivo data from a tumor mouse model. Results: Simulations showed that the uniform and lognormal priors were superior to the reciprocal prior, especially for the parameters D and f and clinically relevant SNR levels. The choice of central tendency measure had less effect on the results, but had some effects on estimation bias. Results based on simulations and in vivo data agreed well, indicating high validity of the simulations. Conclusions: Choice of prior distribution and central tendency measure affects the results of Bayesian IVIM parameter estimates. This must be considered when comparing results from different studies. The best overall quality of IVIM parameter estimates was obtained using the lognormal prior. Magn Reson Med 79:1674–1683, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
- Is Part Of:
- Magnetic resonance in medicine. Volume 79:Issue 3(2018)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 79:Issue 3(2018)
- Issue Display:
- Volume 79, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 79
- Issue:
- 3
- Issue Sort Value:
- 2018-0079-0003-0000
- Page Start:
- 1674
- Page End:
- 1683
- Publication Date:
- 2017-06-19
- Subjects:
- intravoxel incoherent motion -- Bayesian estimation -- prior distribution -- central tendency measure
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26783 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8977.xml