Experimental evaluation of the image quality and dose in digital mammography: Influence of x-ray spectrum. (November 2015)
- Record Type:
- Journal Article
- Title:
- Experimental evaluation of the image quality and dose in digital mammography: Influence of x-ray spectrum. (November 2015)
- Main Title:
- Experimental evaluation of the image quality and dose in digital mammography: Influence of x-ray spectrum
- Authors:
- Tomal, A.
Perez, A.M.M.M
Silva, M.C.
Poletti, M.E. - Abstract:
- Abstract: In this work, we studied experimentally the influence of x-ray spectrum on the contrast-to-noise ratio (CNR) and the average glandular dose (MDG) for two digital mammography systems: Senographe 2000D (GE Medical Systems) and Lorad Selenia (Hologic), with indirect and direct detector imaging technology, respectively. CNR and MGD were determined using PMMA phantoms simulating breasts with thicknesses of 4 cm and 6 cm. All available anode/filter combinations of the systems were evaluated for a wide range of tube voltages values. Results indicated that the Rh/Rh combination provides the highest image quality with the lower mean glandular dose for the Senographe 2000D system. For the Lorad Selenia system, the W/Ag combination at 30 kV showed the best performance, in terms of dose saving and image quality improvement in relation to all tube voltage range. The comparison between the optimal x-ray spectra and those selected by the AEC mode showed that this automatic selection mechanism could be readjusted to optimize the relationship between image quality and dose. Abstract : Highlights: CNR and MGD were studied for different x-ray spectra in two mammographic systems. The optimum x-ray spectrum for each system was determined using a FOM. The results were compared with those obtained using the AEC mode AEC mechanism could be readjusted to optimize the relationship between CNR and MGD.
- Is Part Of:
- Radiation physics and chemistry. Volume 116(2015:Nov.)
- Journal:
- Radiation physics and chemistry
- Issue:
- Volume 116(2015:Nov.)
- Issue Display:
- Volume 116 (2015)
- Year:
- 2015
- Volume:
- 116
- Issue Sort Value:
- 2015-0116-0000-0000
- Page Start:
- 282
- Page End:
- 286
- Publication Date:
- 2015-11
- Subjects:
- Digital mammography -- Contrast-to-noise ratio -- Mean glandular dose -- x-ray spectra -- Figure of Merit
Radiation chemistry -- Periodicals
Radiometry -- Periodicals
Radiation -- Periodicals
Chimie sous rayonnement -- Périodiques
539.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0969806X ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-physics-and-chemistry/ ↗ - DOI:
- 10.1016/j.radphyschem.2015.04.019 ↗
- Languages:
- English
- ISSNs:
- 0969-806X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.984000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8980.xml