Impact of audiovisual biofeedback on interfraction respiratory motion reproducibility in liver cancer stereotactic body radiotherapy. Issue 1 (6th February 2018)
- Record Type:
- Journal Article
- Title:
- Impact of audiovisual biofeedback on interfraction respiratory motion reproducibility in liver cancer stereotactic body radiotherapy. Issue 1 (6th February 2018)
- Main Title:
- Impact of audiovisual biofeedback on interfraction respiratory motion reproducibility in liver cancer stereotactic body radiotherapy
- Authors:
- Pollock, Sean
Tse, Regina
Martin, Darren
McLean, Lisa
Pham, Melissa
Tait, David
Estoesta, Reuben
Whittington, Grant
Turley, Jessica
Kearney, Christopher
Cho, Gwi
Hill, Robin
Pickard, Sheila
Aston, Paul
Makhija, Kuldeep
O'Brien, Ricky
Keall, Paul - Abstract:
- Abstract: Introduction: Irregular breathing motion exacerbates uncertainties throughout a course of radiation therapy. Breathing guidance has demonstrated to improve breathing motion consistency. This was the first clinical implementation of audiovisual biofeedback (AVB) breathing guidance over a course of liver stereotactic body radiotherapy (SBRT) investigating interfraction reproducibility. Methods: Five liver cancer patients underwent a screening procedure prior to CT sim during which patients underwent breathing conditions (i) AVB, or (ii) free breathing (FB). Whichever breathing condition was more regular was utilised for the patient's subsequent course of SBRT. Respiratory motion was obtained from the Varian respiratory position monitoring (RPM) system (Varian Medical Systems). Breathing motion reproducibility was assessed by the variance of displacement across 10 phase‐based respiratory bins over each patient's course of SBRT. Results: The screening procedure yielded the decision to utilise AVB for three patients and FB for two patients. Over the course of SBRT, AVB significantly improved the relative interfraction motion by 32%, from 22% displacement difference for FB patients to 15% difference for AVB patients. Further to this, AVB facilitated sub‐millimetre interfraction reproducibility for two AVB patients. Conclusion: There was significantly less interfraction motion with AVB than FB. These findings demonstrate that AVB is potentially a valuable tool in ensuringAbstract: Introduction: Irregular breathing motion exacerbates uncertainties throughout a course of radiation therapy. Breathing guidance has demonstrated to improve breathing motion consistency. This was the first clinical implementation of audiovisual biofeedback (AVB) breathing guidance over a course of liver stereotactic body radiotherapy (SBRT) investigating interfraction reproducibility. Methods: Five liver cancer patients underwent a screening procedure prior to CT sim during which patients underwent breathing conditions (i) AVB, or (ii) free breathing (FB). Whichever breathing condition was more regular was utilised for the patient's subsequent course of SBRT. Respiratory motion was obtained from the Varian respiratory position monitoring (RPM) system (Varian Medical Systems). Breathing motion reproducibility was assessed by the variance of displacement across 10 phase‐based respiratory bins over each patient's course of SBRT. Results: The screening procedure yielded the decision to utilise AVB for three patients and FB for two patients. Over the course of SBRT, AVB significantly improved the relative interfraction motion by 32%, from 22% displacement difference for FB patients to 15% difference for AVB patients. Further to this, AVB facilitated sub‐millimetre interfraction reproducibility for two AVB patients. Conclusion: There was significantly less interfraction motion with AVB than FB. These findings demonstrate that AVB is potentially a valuable tool in ensuring reproducible interfraction motion. … (more)
- Is Part Of:
- Journal of medical imaging and radiation oncology. Volume 62:Issue 1(2018:Feb.)
- Journal:
- Journal of medical imaging and radiation oncology
- Issue:
- Volume 62:Issue 1(2018:Feb.)
- Issue Display:
- Volume 62, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 62
- Issue:
- 1
- Issue Sort Value:
- 2018-0062-0001-0000
- Page Start:
- 133
- Page End:
- 139
- Publication Date:
- 2018-02-06
- Subjects:
- abdomen -- radiation oncology -- respiratory
Radiology, Medical -- Periodicals
Radiology, Medical -- Australasia -- Periodicals
616.0757 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1754-9485 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/1754-9485.12702 ↗
- Languages:
- English
- ISSNs:
- 1754-9477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5017.072080
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8981.xml