Comparison of cross-matching method for detection of DEA 7 blood incompatibility. (November 2018)
- Record Type:
- Journal Article
- Title:
- Comparison of cross-matching method for detection of DEA 7 blood incompatibility. (November 2018)
- Main Title:
- Comparison of cross-matching method for detection of DEA 7 blood incompatibility
- Authors:
- Spada, Eva
Perego, Roberta
Viñals Flórez, Luis Miguel
del Rosario Perlado Chamizo, Maria
Baggiani, Luciana
Dall'Ara, Paola
Proverbio, Daniela - Abstract:
- We compared 3 major cross-match (XM) tests to identify dog erythrocyte antigen (DEA) 7 blood incompatibilities in dogs as a result of anti–DEA 7 antibodies: gel (GEL), standard tube (TUBE) agglutination, and immunochromatography strips (STRIP). Blood samples from 42 dogs were typed for DEA 7; 2 tested DEA 7–positive (DEA 7+). The 40 DEA 7–negative (DEA 7–) plasma samples were cross-matched against the 2 DEA 7+ and 3 DEA 7– red blood cell (RBC) samples by GEL to identify samples with anti–DEA 7 antibodies. Twenty DEA 7– plasma samples without and with anti–DEA 7 antibodies were cross-matched with samples of the 2 DEA 7+ RBCs in a double-blind fashion using the TUBE and STRIP XM methods. GEL results were used as the reference method for comparison. To determine relationships between results, 2 × 2 tables were used. Cohen kappa coefficient (κ) was calculated between results of GEL and the other 2 methods. With GEL, 21 of 40 XM tests were positive and 19 of 40 negative for anti–DEA 7 antibodies. The same results were obtained by TUBE, whereas only 1 of 40 XM tests was positive by STRIP. There was a statistically significant relationship between results of GEL and TUBE ( p < 0.000) with perfect agreement (κ = 1.000), but not between GEL and STRIP results ( p = 1.000) in which agreement was equivalent to chance (κ = 0.0453). The GEL and TUBE XM tests, but not STRIP, are useful methods for identification of DEA 7 incompatibilities caused by anti–DEA 7 antibodies.
- Is Part Of:
- Journal of veterinary diagnostic investigation. Volume 30:Number 6(2018:Nov.)
- Journal:
- Journal of veterinary diagnostic investigation
- Issue:
- Volume 30:Number 6(2018:Nov.)
- Issue Display:
- Volume 30, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 30
- Issue:
- 6
- Issue Sort Value:
- 2018-0030-0006-0000
- Page Start:
- 911
- Page End:
- 916
- Publication Date:
- 2018-11
- Subjects:
- Anti–DEA 7 antibodies -- blood typing -- canine -- cross-matching -- gel -- immunochromatography -- tube
Veterinary medicine -- Diagnosis -- Periodicals
636.0896075 - Journal URLs:
- http://vdi.sagepub.com/ ↗
http://online.sagepub.com/ ↗ - DOI:
- 10.1177/1040638718806023 ↗
- Languages:
- English
- ISSNs:
- 1040-6387
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 8952.xml