Early Hemodynamic Results in Patients with Small Aortic Annulus after Aortic Valve Replacement. Issue 4 (July 2017)
- Record Type:
- Journal Article
- Title:
- Early Hemodynamic Results in Patients with Small Aortic Annulus after Aortic Valve Replacement. Issue 4 (July 2017)
- Main Title:
- Early Hemodynamic Results in Patients with Small Aortic Annulus after Aortic Valve Replacement
- Authors:
- Olivier Dionne, Pierre
Poulin, Frédéric
Bouchard, Denis
Généreux, Philippe
Ibrahim, Reda
Cartier, Raymond
Lamarche, Yoan
Demers, Philippe - Abstract:
- Objective: Patients with a small aortic annulus (≤21 mm) have an increased risk of patient-prosthesis mismatch after valve replacement. The aim of this study was to compare the early hemodynamic performance of the balloon-expandable transaortic valve implantation Edwards system (SAPIEN) and the sutureless Perceval prostheses. Methods: Fifty patients underwent transcatheter aortic valve implantation, and 113 patients underwent sutureless aortic valve replacement. Mean ± SD aortic annulus diameter was 19.7 ± 1 mm, with no significant difference between groups. SAPIEN valve size was 23 mm in 40 patients (80%) and 26 mm in 10 patients (20%). Perceval valve size was small in 45 patients (40%), medium in 62 patients (55%), and large in 6 patients (5%). Transthoracic Doppler echocardiographic images were collected at baseline and before discharge. Results: There were no significant difference in predischarge effective orifice area (SAPIEN: 1.5 ± 0.5 cm 2 and Perceval: 1.48 ± 0.34 cm 2, P = 0.58) and indexed effective orifice areas (SAPIEN: 0.93 ± 0.32 cm 2 /m 2 and Perceval: 0.88 ± 0.22 cm 2 /m 2, P = 0.42). Predischarge mean ± SD transaortic gradient was lower with the SAPIEN than with Perceval valves (12 ± 6 and 17 ± 6 mm Hg, respectively, P < 0.001). Rates of moderate and severe prosthesis-patient mismatch were similar (SAPIEN: 44% and 10% and Perceval: 50% and 14%, P = 0.53 and 0.75, respectively). There were no moderate-severe paravalvular leaks. Conclusions: Although indexedObjective: Patients with a small aortic annulus (≤21 mm) have an increased risk of patient-prosthesis mismatch after valve replacement. The aim of this study was to compare the early hemodynamic performance of the balloon-expandable transaortic valve implantation Edwards system (SAPIEN) and the sutureless Perceval prostheses. Methods: Fifty patients underwent transcatheter aortic valve implantation, and 113 patients underwent sutureless aortic valve replacement. Mean ± SD aortic annulus diameter was 19.7 ± 1 mm, with no significant difference between groups. SAPIEN valve size was 23 mm in 40 patients (80%) and 26 mm in 10 patients (20%). Perceval valve size was small in 45 patients (40%), medium in 62 patients (55%), and large in 6 patients (5%). Transthoracic Doppler echocardiographic images were collected at baseline and before discharge. Results: There were no significant difference in predischarge effective orifice area (SAPIEN: 1.5 ± 0.5 cm 2 and Perceval: 1.48 ± 0.34 cm 2, P = 0.58) and indexed effective orifice areas (SAPIEN: 0.93 ± 0.32 cm 2 /m 2 and Perceval: 0.88 ± 0.22 cm 2 /m 2, P = 0.42). Predischarge mean ± SD transaortic gradient was lower with the SAPIEN than with Perceval valves (12 ± 6 and 17 ± 6 mm Hg, respectively, P < 0.001). Rates of moderate and severe prosthesis-patient mismatch were similar (SAPIEN: 44% and 10% and Perceval: 50% and 14%, P = 0.53 and 0.75, respectively). There were no moderate-severe paravalvular leaks. Conclusions: Although indexed effective orifice areas were similar, transcatheter aortic valve implantation with the balloon-expandable SAPIEN system yielded lower predischarge transaortic mean gradients than the surgically implanted Perceval, in patients with a small annulus. … (more)
- Is Part Of:
- Innovations. Volume 12:Issue 4(2017)
- Journal:
- Innovations
- Issue:
- Volume 12:Issue 4(2017)
- Issue Display:
- Volume 12, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 12
- Issue:
- 4
- Issue Sort Value:
- 2017-0012-0004-0000
- Page Start:
- 254
- Page End:
- 258
- Publication Date:
- 2017-07
- Subjects:
- Aortic valve replacement -- Echocardiography -- Sutureless aortic valve replacement -- Transcatheter aortic valve replacement
Cardiovascular system -- Surgery -- Periodicals
Heart -- Surgery -- Periodicals
Blood-vessels -- Surgery -- Periodicals
Chest -- Surgery -- Periodicals
Thoracic Surgical Procedures -- methods -- Periodicals
Vascular Surgical Procedures -- methods -- Periodicals
Thorax -- Chirurgie -- Méthodologie -- Périodiques
Vaisseaux sanguins -- Chirurgie -- Méthodologie -- Périodiques
Blood-vessels -- Surgery
Chest -- Surgery
Periodicals
617.41 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01243895-000000000-00000 ↗
http://journals.lww.com/innovjournal/pages/default.aspx ↗
http://www.lww.com/product/?1556-9845 ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1177/155698451701200404 ↗
- Languages:
- English
- ISSNs:
- 1556-9845
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8940.xml