Dependence of intravoxel incoherent motion diffusion MR threshold b-value selection for separating perfusion and diffusion compartments and liver fibrosis diagnostic performance. (January 2019)
- Record Type:
- Journal Article
- Title:
- Dependence of intravoxel incoherent motion diffusion MR threshold b-value selection for separating perfusion and diffusion compartments and liver fibrosis diagnostic performance. (January 2019)
- Main Title:
- Dependence of intravoxel incoherent motion diffusion MR threshold b-value selection for separating perfusion and diffusion compartments and liver fibrosis diagnostic performance
- Authors:
- Wáng, Yì Xiáng J
Li, Yáo T
Chevallier, Olivier
Huang, Hua
Leung, Jason Chi Shun
Chen, Weitian
Lu, Pu-Xuan - Abstract:
- Background: Intravoxel incoherent motion (IVIM) tissue parameters depend on the threshold b -value. Purpose: To explore how threshold b -value impacts PF ( f ), Dslow ( D ), and Dfast ( D* ) values and their performance for liver fibrosis detection. Material and Methods: Fifteen healthy volunteers and 33 hepatitis B patients were included. With a 1.5-T magnetic resonance (MR) scanner and respiration gating, IVIM data were acquired with ten b- values of 10, 20, 40, 60, 80, 100, 150, 200, 400, and 800 s/mm 2 . Signal measurement was performed on the right liver. Segmented-unconstrained analysis was used to compute IVIM parameters and six threshold b -values in the range of 40–200 s/mm 2 were compared. PF, Dslow, and Dfast values were placed along the x- axis, y- axis, and z- axis, and a plane was defined to separate volunteers from patients. Results: Higher threshold b -values were associated with higher PF measurement; while lower threshold b -values led to higher Dslow and Dfast measurements. The dependence of PF, Dslow, and Dfast on threshold b -value differed between healthy livers and fibrotic livers; with the healthy livers showing a higher dependence. Threshold b -value = 60 s/mm 2 showed the largest mean distance between healthy liver datapoints vs. fibrotic liver datapoints, and a classification and regression tree showed that a combination of PF (PF < 9.5%), Dslow (Dslow < 1.239 × 10 –3 mm 2 /s), and Dfast (Dfast < 20.85 × 10 –3 mm 2 /s) differentiated healthyBackground: Intravoxel incoherent motion (IVIM) tissue parameters depend on the threshold b -value. Purpose: To explore how threshold b -value impacts PF ( f ), Dslow ( D ), and Dfast ( D* ) values and their performance for liver fibrosis detection. Material and Methods: Fifteen healthy volunteers and 33 hepatitis B patients were included. With a 1.5-T magnetic resonance (MR) scanner and respiration gating, IVIM data were acquired with ten b- values of 10, 20, 40, 60, 80, 100, 150, 200, 400, and 800 s/mm 2 . Signal measurement was performed on the right liver. Segmented-unconstrained analysis was used to compute IVIM parameters and six threshold b -values in the range of 40–200 s/mm 2 were compared. PF, Dslow, and Dfast values were placed along the x- axis, y- axis, and z- axis, and a plane was defined to separate volunteers from patients. Results: Higher threshold b -values were associated with higher PF measurement; while lower threshold b -values led to higher Dslow and Dfast measurements. The dependence of PF, Dslow, and Dfast on threshold b -value differed between healthy livers and fibrotic livers; with the healthy livers showing a higher dependence. Threshold b -value = 60 s/mm 2 showed the largest mean distance between healthy liver datapoints vs. fibrotic liver datapoints, and a classification and regression tree showed that a combination of PF (PF < 9.5%), Dslow (Dslow < 1.239 × 10 –3 mm 2 /s), and Dfast (Dfast < 20.85 × 10 –3 mm 2 /s) differentiated healthy individuals and all individual fibrotic livers with an area under the curve of logistic regression (AUC) of 1. Conclusion: For segmented-unconstrained analysis, the selection of threshold b -value = 60 s/mm 2 improves IVIM differentiation between healthy livers and fibrotic livers. … (more)
- Is Part Of:
- Acta radiologica. Volume 60:Number 1(2019)
- Journal:
- Acta radiologica
- Issue:
- Volume 60:Number 1(2019)
- Issue Display:
- Volume 60, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 60
- Issue:
- 1
- Issue Sort Value:
- 2019-0060-0001-0000
- Page Start:
- 3
- Page End:
- 12
- Publication Date:
- 2019-01
- Subjects:
- Magnetic resonance imaging (MRI) -- intravoxel incoherent motion (IVIM) -- diffusion -- perfusion -- liver -- fibrosis
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185118774913 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8944.xml