Motion artifacts, lesion type, and parenchymal enhancement in breast MRI: what does really influence diagnostic accuracy?. (January 2019)
- Record Type:
- Journal Article
- Title:
- Motion artifacts, lesion type, and parenchymal enhancement in breast MRI: what does really influence diagnostic accuracy?. (January 2019)
- Main Title:
- Motion artifacts, lesion type, and parenchymal enhancement in breast MRI: what does really influence diagnostic accuracy?
- Authors:
- Clauser, Paola
Dietzel, Matthias
Weber, Michael
Kaiser, Clemens G
Baltzer, Pascal AT - Abstract:
- Background: Motion artifacts can reduce image quality of breast magnetic resonance imaging (MRI). There is a lack of data regarding their effect on diagnostic estimates. Purpose: To evaluate factors that potentially influence readers' diagnostic estimates in breast MRI: motion artifacts; amount of fibroglandular tissue; background parenchymal enhancement; lesion size; and lesion type. Material and Methods: This Institutional Review Board-approved, retrospective, cross-sectional, single-center study included 320 patients (mean age = 55.1 years) with 334 histologically verified breast lesions (139 benign, 195 malignant) who underwent breast MRI. Two expert breast radiologists evaluated the images considering: motion artifacts (1 = minimal to 4 = marked); fibroglandular tissue (BI-RADS FGT); background parenchymal enhancement (BI-RADS BPE); lesion size; lesion type; and BI-RADS score. Univariate (Chi-square) and multivariate (Generalized Estimation Equations [GEE]) statistics were used to identify factors influencing sensitivity, specificity, and accuracy. Results: Lesions were: 230 mass (68.9%) and 59 non-mass (17.7%), no foci. Forty-five lesions (13.5%) did not enhance in MRI but were suspicious or unclear in conventional imaging. Sensitivity, specificity, and accuracy were 93.8%, 83.4%, and 89.8% for Reader 1 and 95.4%, 87.8%, and 91.9% for Reader 2. Lower sensitivity was observed in case of increased motion artifacts ( P = 0.007), non-mass lesions ( P < 0.001), and smallBackground: Motion artifacts can reduce image quality of breast magnetic resonance imaging (MRI). There is a lack of data regarding their effect on diagnostic estimates. Purpose: To evaluate factors that potentially influence readers' diagnostic estimates in breast MRI: motion artifacts; amount of fibroglandular tissue; background parenchymal enhancement; lesion size; and lesion type. Material and Methods: This Institutional Review Board-approved, retrospective, cross-sectional, single-center study included 320 patients (mean age = 55.1 years) with 334 histologically verified breast lesions (139 benign, 195 malignant) who underwent breast MRI. Two expert breast radiologists evaluated the images considering: motion artifacts (1 = minimal to 4 = marked); fibroglandular tissue (BI-RADS FGT); background parenchymal enhancement (BI-RADS BPE); lesion size; lesion type; and BI-RADS score. Univariate (Chi-square) and multivariate (Generalized Estimation Equations [GEE]) statistics were used to identify factors influencing sensitivity, specificity, and accuracy. Results: Lesions were: 230 mass (68.9%) and 59 non-mass (17.7%), no foci. Forty-five lesions (13.5%) did not enhance in MRI but were suspicious or unclear in conventional imaging. Sensitivity, specificity, and accuracy were 93.8%, 83.4%, and 89.8% for Reader 1 and 95.4%, 87.8%, and 91.9% for Reader 2. Lower sensitivity was observed in case of increased motion artifacts ( P = 0.007), non-mass lesions ( P < 0.001), and small lesions ≤ 10 mm ( P < 0.021). No further factors (e.g. BPE, FGT) significantly influenced diagnostic estimates. At multivariate analysis, lesion type and size were retained as independent factors influencing the diagnostic performance ( P < 0.033). Conclusion: Motion artifacts can impair lesion characterization with breast MRI, but lesion type and small size have the strongest influence on diagnostic estimates. … (more)
- Is Part Of:
- Acta radiologica. Volume 60:Number 1(2019)
- Journal:
- Acta radiologica
- Issue:
- Volume 60:Number 1(2019)
- Issue Display:
- Volume 60, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 60
- Issue:
- 1
- Issue Sort Value:
- 2019-0060-0001-0000
- Page Start:
- 19
- Page End:
- 27
- Publication Date:
- 2019-01
- Subjects:
- Breast -- magnetic resonance imaging -- artifacts -- sensitivity -- specificity -- cross-sectional studies
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185118770918 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8944.xml