Fotiadis, Dimitrios I. - Abstract:
- Abstract: A framework for the inflation of micro-CT and histology data using intravascular ultrasound (IVUS) images, is presented. The proposed methodology consists of three steps. In the first step the micro-CT/histological images are manually co-registered with IVUS by experts using fiducial points as landmarks. In the second step the lumen of both the micro-CT/histological images and IVUS images are automatically segmented. Finally, in the third step the micro-CT/histological images are inflated by applying a transformation method on each image. The transformation method is based on the IVUS and micro-CT/histological contour difference. In order to validate the proposed image inflation methodology, plaque areas in the inflated micro-CT and histological images are compared with the ones in the IVUS images. The proposed methodology for inflating micro-CT/histological images increases the sensitivity of plaque area matching between the inflated and the IVUS images (7% and 22% in histological and micro-CT images, respectively). Highlights: A framework for inflating micro-CT/histological images is proposed. The micro-CT/histological images are transformed and validated based on IVUS. A realistic matching between IVUS and micro-CT/histological images is achieved. The overlapping plaque areas are significantly after inflation. The reliability of validation procedure is enhanced in IVUS plaque detection.
- Is Part Of:
- Computers in biology and medicine. Volume 65(2015)
- Journal:
- Computers in biology and medicine
- Issue:
- Volume 65(2015)
- Issue Display:
- Volume 65, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 65
- Issue:
- 2015
- Issue Sort Value:
- 2015-0065-2015-0000
- Page Start:
- 168
- Page End:
- 176
- Publication Date:
- 2015-10-01
- Subjects:
- Micro-CT -- Histology -- Intravascular ultrasound -- Plaque characterization -- Image registration
Medicine -- Data processing -- Periodicals
Biology -- Data processing -- Periodicals
610.285 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00104825/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.compbiomed.2015.02.018 ↗
- Languages:
- English
- ISSNs:
- 0010-4825
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.880000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8946.xml