Feasibility of using ultra‐low pulse rate fluoroscopy during routine diagnostic coronary angiography. Issue 4 (16th July 2018)
- Record Type:
- Journal Article
- Title:
- Feasibility of using ultra‐low pulse rate fluoroscopy during routine diagnostic coronary angiography. Issue 4 (16th July 2018)
- Main Title:
- Feasibility of using ultra‐low pulse rate fluoroscopy during routine diagnostic coronary angiography
- Authors:
- Badawy, Mohamed Khaldoun
Scott, Matthew
Farouque, Omar
Horrigan, Mark
Clark, David J.
Chan, Robert K. - Abstract:
- Abstract: Introduction: Coronary angiogram, while a powerful diagnostic tool in coronary artery disease, is not without an associated risk from ionising radiation. There are a number of factors that influence the amount of radiation the patient receives during the procedure, some of which are under the control of the operator. One of these is an adjustment of the fluoroscopic pulse rate. This study aims to assess the feasibility of using ultra‐low pulse rate (3 pulses per second(pps)) fluoroscopy during routine diagnostic coronary angiogram procedures and the effect it has on fluoroscopy time, diagnostic clarity and radiation dose. Methods: A retrospective study of three operators each undertaking 50 coronary angiogram procedures was performed. One of the operators used a pulse rate of 3 pps and 6 pps for fluoroscopic screening while the control groups used the standard 10 pps mode utilised at this centre. Results: Results demonstrated no reduction of diagnostic clarity, up to a 58% reduction in Dose Area Product and no increase in fluoroscopy time with the 3 pps setting. Conclusions: Findings from this pilot study suggest that utilisation of ultra‐low pulse rate fluoroscopy in routine transfemoral diagnostic coronary angiography in the catheterisation laboratory is feasible. Abstract : This project assessed the feasibility of utilising pulse rates as low as 3 pulses per second (pps) in coronary angiograms. The findings show that by working with application specialists,Abstract: Introduction: Coronary angiogram, while a powerful diagnostic tool in coronary artery disease, is not without an associated risk from ionising radiation. There are a number of factors that influence the amount of radiation the patient receives during the procedure, some of which are under the control of the operator. One of these is an adjustment of the fluoroscopic pulse rate. This study aims to assess the feasibility of using ultra‐low pulse rate (3 pulses per second(pps)) fluoroscopy during routine diagnostic coronary angiogram procedures and the effect it has on fluoroscopy time, diagnostic clarity and radiation dose. Methods: A retrospective study of three operators each undertaking 50 coronary angiogram procedures was performed. One of the operators used a pulse rate of 3 pps and 6 pps for fluoroscopic screening while the control groups used the standard 10 pps mode utilised at this centre. Results: Results demonstrated no reduction of diagnostic clarity, up to a 58% reduction in Dose Area Product and no increase in fluoroscopy time with the 3 pps setting. Conclusions: Findings from this pilot study suggest that utilisation of ultra‐low pulse rate fluoroscopy in routine transfemoral diagnostic coronary angiography in the catheterisation laboratory is feasible. Abstract : This project assessed the feasibility of utilising pulse rates as low as 3 pulses per second (pps) in coronary angiograms. The findings show that by working with application specialists, systems could allow for imaging at 3 pps without adversely affecting the patient. There was a significant reduction in radiation dose when 3 pps was utilised. … (more)
- Is Part Of:
- Journal of medical radiation sciences. Volume 65:Issue 4(2018:Dec.)
- Journal:
- Journal of medical radiation sciences
- Issue:
- Volume 65:Issue 4(2018:Dec.)
- Issue Display:
- Volume 65, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 65
- Issue:
- 4
- Issue Sort Value:
- 2018-0065-0004-0000
- Page Start:
- 252
- Page End:
- 258
- Publication Date:
- 2018-07-16
- Subjects:
- Fluoroscopy -- interventional cardiology -- radiation dose optimisation -- radiation protection
Radiology, Medical -- Periodicals
Radiology, Medical -- Australia -- Periodicals
Radiology, Medical -- New Zealand -- Periodicals
Radiotherapy -- Periodicals
Diagnostic imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2051-3909 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmrs.293 ↗
- Languages:
- English
- ISSNs:
- 2051-3895
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8879.xml