Hirsch, Ariel E. - Abstract:
- Abstract: Purpose: In SBRT for prostate cancer, higher fractional dose to the rectum is a major toxicity concern due to using smaller PTV margin and hypofractionation. We investigate the dosimetric impact on rectum using endorectal balloon (ERB) in prostate SBRT. Materials and Methods: Twenty prostate cancer patients were included in a retrospective study, ten with ERB and 10 without ERB. Optimized SBRT plans were generated on CyberKnife MultiPlan for 5 × 7.25 Gy to PTV under RTOG‐0938 protocol for early‐stage prostate cancer. For the rectum and the anterior half rectum, mean dose and percentage of volumes receiving 50%, 80%, 90%, and 100% prescription dose were compared. Results: Using ERB, mean dose to the rectum was 62 cGy ( P = 0.001) lower per fraction, and 50 cGy ( P = 0.024) lower per fraction for the anterior half rectum. The average V50%, V80%, V90%, and V100% were lower by 9.9% ( P = 0.001), 5.3% ( P = 0.0002), 3.4% ( P = 0.0002), and 1.2% ( P = 0.005) for the rectum, and lower by 10.4% ( P = 0.009), 8.3% ( P = 0.0004), 5.4% ( P = 0.0003), and 2.1% ( P = 0.003) for the anterior half rectum. Conclusions: Significant reductions of dose to the rectum using ERB were observed. This may lead to improvement of the rectal toxicity profiles in prostate SBRT.
- Is Part Of:
- Journal of applied clinical medical physics. Volume 18:Number 3(2017)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 18:Number 3(2017)
- Issue Display:
- Volume 18, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 18
- Issue:
- 3
- Issue Sort Value:
- 2017-0018-0003-0000
- Page Start:
- 37
- Page End:
- 43
- Publication Date:
- 2017-04-13
- Subjects:
- CyberKnife -- endorectal balloon -- prostate cancer -- rectum toxicity -- SBRT
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12063 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8842.xml