A complete 4DCT‐ventilation functional avoidance virtual trial: Developing strategies for prospective clinical trials. (24th April 2017)
- Record Type:
- Journal Article
- Title:
- A complete 4DCT‐ventilation functional avoidance virtual trial: Developing strategies for prospective clinical trials. (24th April 2017)
- Main Title:
- A complete 4DCT‐ventilation functional avoidance virtual trial: Developing strategies for prospective clinical trials
- Authors:
- Waxweiler, Timothy
Schubert, Leah
Diot, Quentin
Faught, Austin
Stuhr, Kelly
Castillo, Richard
Castillo, Edward
Guerrero, Thomas
Rusthoven, Chad
Gaspar, Laurie
Kavanagh, Brian
Miften, Moyed
Vinogradskiy, Yevgeniy - Abstract:
- Abstract: Introduction: 4DCT‐ventilation is an exciting new imaging modality that uses 4DCT data to calculate lung‐function maps. Because 4DCTs are acquired as standard of care for lung cancer patients undergoing radiotherapy, 4DCT‐ventiltation provides functional information at no extra dosimetric or monetary cost to the patient. The development of clinical trials is underway to use 4DCT‐ventilation imaging to spare functional lung in patients undergoing radiotherapy. The purpose of this work was to perform a virtual trial using retrospective data to develop the practical aspects of a 4DCT‐ventilation functional avoidance clinical trial. Methods: The study included 96 stage III lung cancer patients. A 4DCT‐ventilation map was calculated using the patient's 4DCT‐imaging, deformable registration, and a density‐change‐based algorithm. Clinical trial inclusion assessment used quantitative and qualitative metrics based on the patient's spatial ventilation profile. Clinical and functional plans were generated for 25 patients. The functional plan aimed to reduce dose to functional lung while meeting standard target and critical structure constraints. Standard and dose‐function metrics were compared between the clinical and functional plans. Results: Our data showed that 69% and 59% of stage III patients have regional variability in function based on qualitative and quantitative metrics, respectively. Functional planning demonstrated an average reduction of 2.8 Gy (maximum 8.2 Gy)Abstract: Introduction: 4DCT‐ventilation is an exciting new imaging modality that uses 4DCT data to calculate lung‐function maps. Because 4DCTs are acquired as standard of care for lung cancer patients undergoing radiotherapy, 4DCT‐ventiltation provides functional information at no extra dosimetric or monetary cost to the patient. The development of clinical trials is underway to use 4DCT‐ventilation imaging to spare functional lung in patients undergoing radiotherapy. The purpose of this work was to perform a virtual trial using retrospective data to develop the practical aspects of a 4DCT‐ventilation functional avoidance clinical trial. Methods: The study included 96 stage III lung cancer patients. A 4DCT‐ventilation map was calculated using the patient's 4DCT‐imaging, deformable registration, and a density‐change‐based algorithm. Clinical trial inclusion assessment used quantitative and qualitative metrics based on the patient's spatial ventilation profile. Clinical and functional plans were generated for 25 patients. The functional plan aimed to reduce dose to functional lung while meeting standard target and critical structure constraints. Standard and dose‐function metrics were compared between the clinical and functional plans. Results: Our data showed that 69% and 59% of stage III patients have regional variability in function based on qualitative and quantitative metrics, respectively. Functional planning demonstrated an average reduction of 2.8 Gy (maximum 8.2 Gy) in the mean dose to functional lung. Conclusions: Our work demonstrated that 60–70% of stage III patients would be eligible for functional planning and that a typical functional lung mean dose reduction of 2.8 Gy can be expected relative to standard clinical plans. These findings provide salient data for the development of functional clinical trials. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 18:Number 3(2017)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 18:Number 3(2017)
- Issue Display:
- Volume 18, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 18
- Issue:
- 3
- Issue Sort Value:
- 2017-0018-0003-0000
- Page Start:
- 144
- Page End:
- 152
- Publication Date:
- 2017-04-24
- Subjects:
- CT ventilation -- functional imaging -- lung cancer
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12086 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8842.xml