Continuous Noninvasive Arterial Pressure Monitoring Using the Vascular Unloading Technique (CNAP System) in Obese Patients During Laparoscopic Bariatric Operations. (February 2018)
- Record Type:
- Journal Article
- Title:
- Continuous Noninvasive Arterial Pressure Monitoring Using the Vascular Unloading Technique (CNAP System) in Obese Patients During Laparoscopic Bariatric Operations. (February 2018)
- Main Title:
- Continuous Noninvasive Arterial Pressure Monitoring Using the Vascular Unloading Technique (CNAP System) in Obese Patients During Laparoscopic Bariatric Operations
- Authors:
- Rogge, Dorothea E.
Nicklas, Julia Y.
Haas, Sebastian A.
Reuter, Daniel A.
Saugel, Bernd - Abstract:
- Abstract : BACKGROUND: Increasing rates of obesity create new challenges for hemodynamic monitoring in the perioperative phase. Continuous monitoring of arterial pressure (AP) is important in severely obese patients who are at particular risk for cardiovascular complications. Innovative technologies for continuous noninvasive AP monitoring are now available. In this study, we aimed to compare continuous noninvasive AP measurements using the vascular unloading technique (CNAP system; CNSystems, Graz, Austria) compared with invasive AP measurements (radial arterial catheter) in severely obese patients during laparoscopic bariatric surgery. METHODS: In 29 severely obese patients (mean body mass index 48.1 kg/m 2 ), we simultaneously recorded noninvasive and invasive AP measurements over a period of 45 minutes and averaged the measurements using 10-second episodes. We compared noninvasive (test method) and invasive (reference method) AP measurements using Bland-Altman analysis and 4-quadrant plot/concordance analysis (2-minute interval). RESULTS: We observed a mean of the differences (±SD, 95% limits of agreement) between the AP values obtained by the CNAP system and the invasively assessed AP values of 7.9 mm Hg (±9.6 mm Hg, −11.2 to 27.0 mm Hg) for mean AP, 4.8 mm Hg (±15.8 mm Hg, −26.5 to 36.0 mm Hg) for systolic AP, and 9.5 mm Hg (±10.3 mm Hg, −10.9 to 29.9 mm Hg) for diastolic AP, respectively. The concordance rate was 97.5% for mean AP, 95.0% for systolic AP, and 96.7% forAbstract : BACKGROUND: Increasing rates of obesity create new challenges for hemodynamic monitoring in the perioperative phase. Continuous monitoring of arterial pressure (AP) is important in severely obese patients who are at particular risk for cardiovascular complications. Innovative technologies for continuous noninvasive AP monitoring are now available. In this study, we aimed to compare continuous noninvasive AP measurements using the vascular unloading technique (CNAP system; CNSystems, Graz, Austria) compared with invasive AP measurements (radial arterial catheter) in severely obese patients during laparoscopic bariatric surgery. METHODS: In 29 severely obese patients (mean body mass index 48.1 kg/m 2 ), we simultaneously recorded noninvasive and invasive AP measurements over a period of 45 minutes and averaged the measurements using 10-second episodes. We compared noninvasive (test method) and invasive (reference method) AP measurements using Bland-Altman analysis and 4-quadrant plot/concordance analysis (2-minute interval). RESULTS: We observed a mean of the differences (±SD, 95% limits of agreement) between the AP values obtained by the CNAP system and the invasively assessed AP values of 7.9 mm Hg (±9.6 mm Hg, −11.2 to 27.0 mm Hg) for mean AP, 4.8 mm Hg (±15.8 mm Hg, −26.5 to 36.0 mm Hg) for systolic AP, and 9.5 mm Hg (±10.3 mm Hg, −10.9 to 29.9 mm Hg) for diastolic AP, respectively. The concordance rate was 97.5% for mean AP, 95.0% for systolic AP, and 96.7% for diastolic AP, respectively. CONCLUSIONS: In the setting of laparoscopic bariatric surgery, continuous noninvasive AP monitoring with the CNAP system showed good trending capabilities compared with continuous invasive AP measurements obtained with a radial arterial catheter. However, absolute CNAP- and arterial catheter–derived AP values were not interchangeable. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Anesthesia & analgesia. Volume 126:Number 2(2018)
- Journal:
- Anesthesia & analgesia
- Issue:
- Volume 126:Number 2(2018)
- Issue Display:
- Volume 126, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 126
- Issue:
- 2
- Issue Sort Value:
- 2018-0126-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-02
- Subjects:
- Anesthesiology -- Periodicals
Anesthesia
Anesthesiology
Analgesia
Analgesics
Anesthesiology -- Periodicals
617.9605 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00000539-000000000-00000 ↗
http://journals.lww.com/anesthesia-analgesia/Pages/default.aspx ↗
http://www.anesthesia-analgesia.org ↗
http://journals.lww.com ↗ - DOI:
- 10.1213/ANE.0000000000002660 ↗
- Languages:
- English
- ISSNs:
- 0003-2999
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0900.500000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8839.xml