Impact of patient weight on tumor visibility based on human-shaped phantom simulation study in PET imaging system. (October 2015)
- Record Type:
- Journal Article
- Title:
- Impact of patient weight on tumor visibility based on human-shaped phantom simulation study in PET imaging system. (October 2015)
- Main Title:
- Impact of patient weight on tumor visibility based on human-shaped phantom simulation study in PET imaging system
- Authors:
- Musarudin, M.
Saripan, M.I.
Mashohor, S.
Saad, W.H.M.
Nordin, A.J.
Hashim, S. - Abstract:
- Abstract: Energy window technique has been implemented in all positron emission tomography (PET) imaging protocol, with the aim to remove the unwanted low energy photons. Current practices in our institution however are performed by using default energy threshold level regardless of the weight of the patient. Phantom size, which represents the size of the patient's body, is the factor that determined the level of scatter fraction during PET imaging. Thus, the motivation of this study is to determine the optimum energy threshold level for different sizes of human-shaped phantom, to represent underweight, normal, overweight and obese patients. In this study, the scanner was modeled by using Monte Carlo code, version MCNP5. Five different sizes of elliptical-cylinder shaped of human-sized phantoms with diameter ranged from 15 to 30 cm were modeled. The tumor was modeled by a cylindrical line source filled with 1.02 MeV positron emitters at the center of the phantom. Various energy window widths, in the ranged of 10–50% were implemented to the data. In conclusion, the phantom mass volume did influence the scatter fraction within the volume. Bigger phantom caused more scattering events and thus led to coincidence counts lost. We evaluated the impact of phantom sizes on the sensitivity and visibility of the simulated models. Implementation of wider energy window improved the sensitivity of the system and retained the coincidence photons lost. Visibility of the tumor improved as anAbstract: Energy window technique has been implemented in all positron emission tomography (PET) imaging protocol, with the aim to remove the unwanted low energy photons. Current practices in our institution however are performed by using default energy threshold level regardless of the weight of the patient. Phantom size, which represents the size of the patient's body, is the factor that determined the level of scatter fraction during PET imaging. Thus, the motivation of this study is to determine the optimum energy threshold level for different sizes of human-shaped phantom, to represent underweight, normal, overweight and obese patients. In this study, the scanner was modeled by using Monte Carlo code, version MCNP5. Five different sizes of elliptical-cylinder shaped of human-sized phantoms with diameter ranged from 15 to 30 cm were modeled. The tumor was modeled by a cylindrical line source filled with 1.02 MeV positron emitters at the center of the phantom. Various energy window widths, in the ranged of 10–50% were implemented to the data. In conclusion, the phantom mass volume did influence the scatter fraction within the volume. Bigger phantom caused more scattering events and thus led to coincidence counts lost. We evaluated the impact of phantom sizes on the sensitivity and visibility of the simulated models. Implementation of wider energy window improved the sensitivity of the system and retained the coincidence photons lost. Visibility of the tumor improved as an appropriate energy window implemented for the different sizes of phantom. Highlights: Optimizing the energy window improved the sensitivity of the PET system. Improving the visibility of the tumors using the optimized energy window. Recommendations on the optimized energy windows for different body sizes. Using simulated phantom using MCNP to determine various body sizes. … (more)
- Is Part Of:
- Radiation physics and chemistry. Volume 115(2015:Oct.)
- Journal:
- Radiation physics and chemistry
- Issue:
- Volume 115(2015:Oct.)
- Issue Display:
- Volume 115 (2015)
- Year:
- 2015
- Volume:
- 115
- Issue Sort Value:
- 2015-0115-0000-0000
- Page Start:
- 81
- Page End:
- 87
- Publication Date:
- 2015-10
- Subjects:
- Energy threshold -- Positron emission tomography (PET) -- Radiation and image optimization -- Monte Carlo -- MCNP5
Radiation chemistry -- Periodicals
Radiometry -- Periodicals
Radiation -- Periodicals
Chimie sous rayonnement -- Périodiques
539.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0969806X ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-physics-and-chemistry/ ↗ - DOI:
- 10.1016/j.radphyschem.2015.05.039 ↗
- Languages:
- English
- ISSNs:
- 0969-806X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.984000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8831.xml