Balloon-Based Organ Retractor With Increased Safety and Reduced Invasiveness During Video-Assisted Thoracoscopic Surgery. (October 2018)
- Record Type:
- Journal Article
- Title:
- Balloon-Based Organ Retractor With Increased Safety and Reduced Invasiveness During Video-Assisted Thoracoscopic Surgery. (October 2018)
- Main Title:
- Balloon-Based Organ Retractor With Increased Safety and Reduced Invasiveness During Video-Assisted Thoracoscopic Surgery
- Authors:
- Taniguchi, Daisuke
Matsumoto, Keitaro
Kondo, Yoshihiro
Shimoyama, Koichiro
Hashimoto, Yasumasa
Elgalad, Abdelmotagaly
Obata, Tomohiro
Miyazaki, Takuro
Tsuchiya, Tomoshi
Matsuo, Naoto
Lawn, Murray John
Yamasaki, Naoya
Yamamoto, Ikuo
Nagayasu, Takeshi - Abstract:
- Objectives . In recent years, video-assisted thoracoscopic surgery (VATS) has increasingly become the preferred technique for thoracic surgery. However, the inherent characteristics of the lungs as large, soft, slippery, and delicate creates difficulties for pulmonary surgery. In this article, we outline the development and assessment of a balloon-based organ retractor for VATS via collaboration between medical and engineering personnel. Methods . A dry lab trial and accompanying questionnaire assessment were performed by a group of thoracic surgeons. Objective pressure measurements were obtained, and animal experiment on pigs was performed. Results . In the dry lab trial, use of the developed organ retractor required significantly less time and resulted in fewer difficulties than using a Cherry Dissector. The measured pressure per mm 2 of the developed retractor was clearly lower than that for the Cherry Dissector. The questionnaire completed by the surgeons following the dry lab and animal experiments showed that most of the surgeons (7 surgeons out of 9) were satisfied with the quality of the balloon-based retractor based on a score of 3.13 ± 0.28 (mean ± standard deviation) out of 4.0. During the animal experiment, the balloon-based retractor provided stable and clear viewing with minimal need for adjustment. Conclusion . This balloon-based retractor could contribute to increased safety and less-invasive VATS.
- Is Part Of:
- Surgical innovation. Volume 25:Number 5(2018)
- Journal:
- Surgical innovation
- Issue:
- Volume 25:Number 5(2018)
- Issue Display:
- Volume 25, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 25
- Issue:
- 5
- Issue Sort Value:
- 2018-0025-0005-0000
- Page Start:
- 435
- Page End:
- 443
- Publication Date:
- 2018-10
- Subjects:
- video-assisted thoracoscopic surgery -- VATS -- organ retractor -- inflatable balloon mechanism -- medical-engineering collaboration
Surgery, Operative -- Periodicals
Endoscopic surgery -- Periodicals
Laparoscopic surgery -- Periodicals
Surgical Procedures, Operative -- Periodicals
Surgical Procedures, Minimally Invasive -- Periodicals
Diffusion of Innovation -- Periodicals
Chirurgie opératoire -- Périodiques
Chirurgie endoscopique -- Périodiques
Chirurgie laparoscopique -- Périodiques
617.91 - Journal URLs:
- http://journals.sagepub.com/home/sri ↗
http://sri.sagepub.com/ ↗
http://www.sagepub.com/journalsProdDesc.nav?prodId=Journal201793 ↗
http://www.sagepublications.com/ ↗ - DOI:
- 10.1177/1553350618784473 ↗
- Languages:
- English
- ISSNs:
- 1553-3506
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8819.xml