Impact of SSF on Diagnostic Performance of Coronary Computed Tomography Angiography Within 1 Heart Beat in Patients With High Heart Rate Using a 256-Row Detector Computed Tomography. Issue 1 (January 2018)
- Record Type:
- Journal Article
- Title:
- Impact of SSF on Diagnostic Performance of Coronary Computed Tomography Angiography Within 1 Heart Beat in Patients With High Heart Rate Using a 256-Row Detector Computed Tomography. Issue 1 (January 2018)
- Main Title:
- Impact of SSF on Diagnostic Performance of Coronary Computed Tomography Angiography Within 1 Heart Beat in Patients With High Heart Rate Using a 256-Row Detector Computed Tomography
- Authors:
- Liang, Junfu
Wang, Hui
Xu, Lei
Dong, Li
Fan, Zhanming
Wang, Rui
Sun, Zhonghua - Abstract:
- Abstract : Objective: The aim of this study was to investigate the impact of a motion-correction algorithm on diagnostic accuracy of coronary computed tomography angiography (CCTA) within 1 heart beat in patients with high heart rate (HR) using a 256-row detector CT. Method: Sixty-four consecutive patients with known or suspected coronary artery disease (symptomatic) and with HR of 75 beats per minute or greater (mean [SD] HR, 82.6 [7.3] beats per minute) undergoing CCTA and invasive coronary angiography within 4 weeks were prospectively enrolled. Coronary computed tomography angiography was performed with a 256-row detector CT (Revolution CT, GE Healthcare) using prospectively electrocardiography-triggered volume scan in 1 heart beat. All images were reconstructed using standard (STD) algorithm and a motion-correction algorithm reconstruction (Snapshot Freeze SSF; GE Healthcare) technique. The image quality of coronary artery segments was evaluated by 2 experienced radiologists using a 4-point scale based on the 18-segment model. Diagnostic accuracy was compared between STD and SSF for significant lumen stenosis (≥50%) of each segment with invasive coronary angiography as the reference standard for determining significant stenosis. Results: The diagnostic sensitivity, specificity, positive predictive value, and negative predictive value with STD and SSF were 93.7%, 85.1%, 50.2%, and 98.8% versus 91.9%, 95.8%, 77.9%, and 98.7% on per-segment assessment; 98.7%, 74.0%, 62.9%,Abstract : Objective: The aim of this study was to investigate the impact of a motion-correction algorithm on diagnostic accuracy of coronary computed tomography angiography (CCTA) within 1 heart beat in patients with high heart rate (HR) using a 256-row detector CT. Method: Sixty-four consecutive patients with known or suspected coronary artery disease (symptomatic) and with HR of 75 beats per minute or greater (mean [SD] HR, 82.6 [7.3] beats per minute) undergoing CCTA and invasive coronary angiography within 4 weeks were prospectively enrolled. Coronary computed tomography angiography was performed with a 256-row detector CT (Revolution CT, GE Healthcare) using prospectively electrocardiography-triggered volume scan in 1 heart beat. All images were reconstructed using standard (STD) algorithm and a motion-correction algorithm reconstruction (Snapshot Freeze SSF; GE Healthcare) technique. The image quality of coronary artery segments was evaluated by 2 experienced radiologists using a 4-point scale based on the 18-segment model. Diagnostic accuracy was compared between STD and SSF for significant lumen stenosis (≥50%) of each segment with invasive coronary angiography as the reference standard for determining significant stenosis. Results: The diagnostic sensitivity, specificity, positive predictive value, and negative predictive value with STD and SSF were 93.7%, 85.1%, 50.2%, and 98.8% versus 91.9%, 95.8%, 77.9%, and 98.7% on per-segment assessment; 98.7%, 74.0%, 62.9%, and 99.2% versus 96.2%, 94.4%, 77.9%, and 98.7% on per-artery assessment; and 100%, 14.3%, 70.5%, and 100% versus 100%, 85.7%, 93.5%, and 100% on per-patient assessment, respectively. There was a significant difference in accuracy between STD and SFF on per-patient level 71.9% versus 95.3%, on per-artery level 81.6% versus 94.9%, and per-segment level 86.3% versus 95.3%, respectively. The area under receiver operating characteristics curve analysis also showed a significant improvement on diagnostic performance with the SSF technique versus with the STD algorithm on per-patient level ( P < 0.001), with corresponding area under the curve being 0.91 (95% confidence interval, 0.79–1.00) and 0.60 (95% confidence interval, 0.44–0.75). The mean effective dose was 2.0 mSv. Conclusions: Coronary computed tomography angiography can be performed in patients with high HR within 1 heart beat yielding low radiation dose. The use of SSF technique reconstruction for 1 heart beat CCTA achieves significant improvements in image quality and diagnostic value. … (more)
- Is Part Of:
- Journal of computer assisted tomography. Volume 42:Issue 1(2018)
- Journal:
- Journal of computer assisted tomography
- Issue:
- Volume 42:Issue 1(2018)
- Issue Display:
- Volume 42, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 42
- Issue:
- 1
- Issue Sort Value:
- 2018-0042-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-01
- Subjects:
- heart rate -- coronary CT angiography -- diagnostic performance -- motion -- invasive coronary angiography
Tomography -- Periodicals
Tomography -- Periodicals
Tomography
Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/jcat/pages/default.aspx ↗
http://ovidsp.tx.ovid.com ↗
http://www.jcat.org ↗
http://www.rad.bqsm.edu/jcat ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0363-8715 ↗ - DOI:
- 10.1097/RCT.0000000000000641 ↗
- Languages:
- English
- ISSNs:
- 0363-8715
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4963.650000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8816.xml