Quasi-static cyclic tests of precast bridge columns with different connection details for high seismic zones. (1st March 2018)
- Record Type:
- Journal Article
- Title:
- Quasi-static cyclic tests of precast bridge columns with different connection details for high seismic zones. (1st March 2018)
- Main Title:
- Quasi-static cyclic tests of precast bridge columns with different connection details for high seismic zones
- Authors:
- Wang, Zhiqiang
Qu, Hongya
Li, Tiantian
Wei, Hongyi
Wang, Hao
Duan, Hongliang
Jiang, Haixi - Abstract:
- Highlights: Seismic behavior of six precast bridge columns with different connections are studied. The precast columns are compared with cast-in-place benchmark for feasibility study. The specimens are designed based on real bridge application in high seismic zones. Finite element analyses of the different precast column types are presented. Abstract: In this study, seven 1/3-scale bridge column specimens are investigated under the same quasi-static cyclic loading protocol both experimentally and numerically. The specimens consist of one cast-in-place (CIP) reference column and six precast columns. The precast columns are designed with different connection details, and they are tested for the feasibility study of the urban viaducts of highway S6 in Shanghai, China. The seismic performance of the precast columns needs to be investigated and verified prior to the practical application of these connection designs. Based on the experimental results, the precast specimens solely using mild reinforcement exhibit similar hysteretic behavior to the CIP reference column, though various grouted connection approaches are employed. The differences between these precast specimens and the CIP reference column are less than 15% for all indices. The precast specimens with bonded tendons (prestressing strands or prestressing bars) retain higher strength, but no less than 30% decrease of energy dissipation capacity is found. The bonded prestressing strands give at least 10% increase inHighlights: Seismic behavior of six precast bridge columns with different connections are studied. The precast columns are compared with cast-in-place benchmark for feasibility study. The specimens are designed based on real bridge application in high seismic zones. Finite element analyses of the different precast column types are presented. Abstract: In this study, seven 1/3-scale bridge column specimens are investigated under the same quasi-static cyclic loading protocol both experimentally and numerically. The specimens consist of one cast-in-place (CIP) reference column and six precast columns. The precast columns are designed with different connection details, and they are tested for the feasibility study of the urban viaducts of highway S6 in Shanghai, China. The seismic performance of the precast columns needs to be investigated and verified prior to the practical application of these connection designs. Based on the experimental results, the precast specimens solely using mild reinforcement exhibit similar hysteretic behavior to the CIP reference column, though various grouted connection approaches are employed. The differences between these precast specimens and the CIP reference column are less than 15% for all indices. The precast specimens with bonded tendons (prestressing strands or prestressing bars) retain higher strength, but no less than 30% decrease of energy dissipation capacity is found. The bonded prestressing strands give at least 10% increase in strength compared with the CIP reference column, while the bonded prestressing bars provide approximately 50% improvement. The precast specimen utilizing unbonded tendon (prestressing strands) shows unique self-centering capability with equivalent energy dissipation capacity of the CIP reference column, but it has 33% lower ductility. Finite element modeling is performed and calibrated with the test data. Bond-slip behavior near column-to-footing interface is modeled by using a ZeroLength element at the interface. Buckling, fatigue and strength reduction of reinforcement are also considered in the model. Hysteretic behaviors of the specimens can be effectively simulated, and differences of ultimate strengths between the experimental and numerical results are less than 9%. … (more)
- Is Part Of:
- Engineering structures. Volume 158(2018)
- Journal:
- Engineering structures
- Issue:
- Volume 158(2018)
- Issue Display:
- Volume 158, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 158
- Issue:
- 2018
- Issue Sort Value:
- 2018-0158-2018-0000
- Page Start:
- 13
- Page End:
- 27
- Publication Date:
- 2018-03-01
- Subjects:
- Bridge column -- Cyclic loading -- Finite element method -- Grouted connection -- Precast concrete -- Prestressing steel -- Segmental construction -- Seismic performance
Structural engineering -- Periodicals
Structural analysis (Engineering) -- Periodicals
Construction, Technique de la -- Périodiques
Génie parasismique -- Périodiques
Pression du vent -- Périodiques
Earthquake engineering
Structural engineering
Wind-pressure
Periodicals
624.105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01410296 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.engstruct.2017.12.035 ↗
- Languages:
- English
- ISSNs:
- 0141-0296
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3770.032000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8817.xml