Critical Importance of Low-Dose Tissue Plasminogen Activator Policy for Treating Intraoperative Pulmonary Thromboembolism During Liver Transplantation. (December 2018)
- Record Type:
- Journal Article
- Title:
- Critical Importance of Low-Dose Tissue Plasminogen Activator Policy for Treating Intraoperative Pulmonary Thromboembolism During Liver Transplantation. (December 2018)
- Main Title:
- Critical Importance of Low-Dose Tissue Plasminogen Activator Policy for Treating Intraoperative Pulmonary Thromboembolism During Liver Transplantation
- Authors:
- Mandell, Daniel
Planinsic, Raymond
Melean, Fernando
Hughes, Christopher
Tevar, Amit D.
Humar, Abhinav
Cassidy, Benjamin J.
Simmons, Richard
Dewolf, Andre
Sakai, Tetsuro - Abstract:
- Tissue plasminogen activator (tPA) has been reported to treat intraoperative pulmonary thromboembolism (PTE) during liver transplantation (LT). However, tPA administration is often delayed due to fear of uncontrolled bleeding and storage in a refrigerator outside of operating rooms. Various dosages of tPA were used. We hypothesize that a policy of tPA storage and low dosage use improves patient outcomes. At a transplantation center, a multidisciplinary committee has implemented a tPA policy since April 2014, which includes the following: (1) timely administering of low-dose tPA (0.5-4 mg) for intraoperative PTE; (2) keeping 2 vials of tPA (2 mg/vial) in the operating room at room temperature; and (3) transferring unused tPA vials to the cardiology catheterization laboratory for next-day use. A prospective observational study was conducted to record the incidence and outcome of PTE during LTs. Over the next 19 months, 99 adult deceased donor LTs were performed with 1 (1.0%) intraoperative PTE. A 45-year-old woman with hepatitis C developed PTE within 5 minutes after graft reperfusion. A 2-mg tPA was immediately administered via a central venous line with hemodynamic improvement and clot lysis. Thromboelastography was normalized in 90 minutes. Five LT cases developing intraoperative PTE have been reported to receive "standard" dosages of tPA (20-110 mg) or urokinase (4400 IU/kg), which were administered more than 20 minutes after the diagnosis of PTE. One intraoperative deathTissue plasminogen activator (tPA) has been reported to treat intraoperative pulmonary thromboembolism (PTE) during liver transplantation (LT). However, tPA administration is often delayed due to fear of uncontrolled bleeding and storage in a refrigerator outside of operating rooms. Various dosages of tPA were used. We hypothesize that a policy of tPA storage and low dosage use improves patient outcomes. At a transplantation center, a multidisciplinary committee has implemented a tPA policy since April 2014, which includes the following: (1) timely administering of low-dose tPA (0.5-4 mg) for intraoperative PTE; (2) keeping 2 vials of tPA (2 mg/vial) in the operating room at room temperature; and (3) transferring unused tPA vials to the cardiology catheterization laboratory for next-day use. A prospective observational study was conducted to record the incidence and outcome of PTE during LTs. Over the next 19 months, 99 adult deceased donor LTs were performed with 1 (1.0%) intraoperative PTE. A 45-year-old woman with hepatitis C developed PTE within 5 minutes after graft reperfusion. A 2-mg tPA was immediately administered via a central venous line with hemodynamic improvement and clot lysis. Thromboelastography was normalized in 90 minutes. Five LT cases developing intraoperative PTE have been reported to receive "standard" dosages of tPA (20-110 mg) or urokinase (4400 IU/kg), which were administered more than 20 minutes after the diagnosis of PTE. One intraoperative death and one later mortality were noted with intracranial hemorrhages/infarction of 3 cases. The multidisciplinary low-dose tPA policy for PTE was suggested to be effective. … (more)
- Is Part Of:
- Seminars in cardiothoracic and vascular anesthesia. Volume 22:Number 4(2018)
- Journal:
- Seminars in cardiothoracic and vascular anesthesia
- Issue:
- Volume 22:Number 4(2018)
- Issue Display:
- Volume 22, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 22
- Issue:
- 4
- Issue Sort Value:
- 2018-0022-0004-0000
- Page Start:
- 376
- Page End:
- 382
- Publication Date:
- 2018-12
- Subjects:
- cardiovascular disease -- coagulation and hemostasis -- complication -- echocardiography -- patient safety
Cardiovascular system -- Surgery -- Methods -- Periodicals
Chest -- Surgery -- Methods -- Periodicals
Anesthesia -- Periodicals
Anesthetics -- Periodicals
Anesthesia -- Periodicals
Anesthetics -- Periodicals
Cardiovascular Surgical Procedures -- methods -- Periodicals
Thoracic Surgical Procedures -- methods -- Periodicals
617.96 - Journal URLs:
- http://scv.sagepub.com/ ↗
http://www.westminsterpublications.com/CVA/ ↗
http://www.sagepublications.com/ ↗ - DOI:
- 10.1177/1089253218760221 ↗
- Languages:
- English
- ISSNs:
- 1089-2532
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8802.xml