Modeling in Colorectal Cancer Screening: Assessing External and Predictive Validity of MISCAN-Colon Microsimulation Model Using NORCCAP Trial Results. (November 2018)
- Record Type:
- Journal Article
- Title:
- Modeling in Colorectal Cancer Screening: Assessing External and Predictive Validity of MISCAN-Colon Microsimulation Model Using NORCCAP Trial Results. (November 2018)
- Main Title:
- Modeling in Colorectal Cancer Screening: Assessing External and Predictive Validity of MISCAN-Colon Microsimulation Model Using NORCCAP Trial Results
- Authors:
- Buskermolen, Maaike
Gini, Andrea
Naber, Steffie K.
Toes-Zoutendijk, Esther
de Koning, Harry J.
Lansdorp-Vogelaar, Iris - Abstract:
- Background. Microsimulation models are increasingly being used to inform colorectal cancer (CRC) screening recommendations. MISCAN-Colon is an example of such a model, used to inform the Dutch CRC screening program and US Preventive Services Task Force guidelines. Assessing the validity of these models is essential to provide transparency regarding their performance. In this study, we tested the external and predictive validity of MISCAN-Colon.Methods. We validated MISCAN-Colon using the Norwegian Colorectal Cancer Prevention (NORCCAP) trial, a randomized controlled trial that examined the effectiveness of once-only flexible sigmoidoscopy (FS) screening. We simulated the study population and design of the NORCCAP trial in MISCAN-Colon and compared 10- to 12-year model-predicted hazard ratios (HRs) for overall and distal CRC incidence and mortality to those observed. In addition, we compared the numbers of screen-detected neoplasia. Finally, we predicted the trial's future results to allow for the assessment of predictive validity.Results. MISCAN-Colon predicted an HR for overall CRC incidence (0.85), distal CRC incidence (0.82), overall CRC mortality (0.68), and distal CRC mortality (0.62). These were within the limits of the 95% confidence intervals of the NORCCAP trial results. Similar results were observed for the number of screen-detected cancers. The model significantly underestimated the number of screen-detected adenomas. Model-predicted HRs for CRC incidence andBackground. Microsimulation models are increasingly being used to inform colorectal cancer (CRC) screening recommendations. MISCAN-Colon is an example of such a model, used to inform the Dutch CRC screening program and US Preventive Services Task Force guidelines. Assessing the validity of these models is essential to provide transparency regarding their performance. In this study, we tested the external and predictive validity of MISCAN-Colon.Methods. We validated MISCAN-Colon using the Norwegian Colorectal Cancer Prevention (NORCCAP) trial, a randomized controlled trial that examined the effectiveness of once-only flexible sigmoidoscopy (FS) screening. We simulated the study population and design of the NORCCAP trial in MISCAN-Colon and compared 10- to 12-year model-predicted hazard ratios (HRs) for overall and distal CRC incidence and mortality to those observed. In addition, we compared the numbers of screen-detected neoplasia. Finally, we predicted the trial's future results to allow for the assessment of predictive validity.Results. MISCAN-Colon predicted an HR for overall CRC incidence (0.85), distal CRC incidence (0.82), overall CRC mortality (0.68), and distal CRC mortality (0.62). These were within the limits of the 95% confidence intervals of the NORCCAP trial results. Similar results were observed for the number of screen-detected cancers. The model significantly underestimated the number of screen-detected adenomas. Model-predicted HRs for CRC incidence and mortality up to 15- to 17-year follow-up were 0.84 and 0.72, respectively.Conclusion. Although the underestimation of screen-detected adenomas requires further investigation, MISCAN-Colon is able to make a valid replication of the CRC incidence and mortality reduction of an FS screening trial, which suggests that it can be considered a useful tool to support decision making on CRC screening. … (more)
- Is Part Of:
- Medical decision making. Volume 38:Number 8(2018)
- Journal:
- Medical decision making
- Issue:
- Volume 38:Number 8(2018)
- Issue Display:
- Volume 38, Issue 8 (2018)
- Year:
- 2018
- Volume:
- 38
- Issue:
- 8
- Issue Sort Value:
- 2018-0038-0008-0000
- Page Start:
- 917
- Page End:
- 929
- Publication Date:
- 2018-11
- Subjects:
- cancer screening -- colorectal neoplasm -- computer simulation -- microsimulation modeling
Medical policy -- Periodicals
Clinical medicine -- Decision making -- Periodicals
Medicine -- Periodicals
Médecine clinique -- Prise de décision -- Périodiques
362.1 - Journal URLs:
- http://journals.sagepub.com/home/mdm ↗
http://www.ingenta.com/journals/browse/sage/j501 ↗
http://www.sagepublications.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0272-989x;screen=info;ECOIP ↗ - DOI:
- 10.1177/0272989X18806497 ↗
- Languages:
- English
- ISSNs:
- 0272-989X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8786.xml