Supraciliary versus intrascleral implantation with hema implant (Esnoper V‐2000) in deep sclerectomy: a multicenter randomized controlled trial. Issue 7 (31st May 2018)
- Record Type:
- Journal Article
- Title:
- Supraciliary versus intrascleral implantation with hema implant (Esnoper V‐2000) in deep sclerectomy: a multicenter randomized controlled trial. Issue 7 (31st May 2018)
- Main Title:
- Supraciliary versus intrascleral implantation with hema implant (Esnoper V‐2000) in deep sclerectomy: a multicenter randomized controlled trial
- Authors:
- Belda, Jose I.
Loscos‐Arenas, Jordi
Mermoud, Andre
Lozano, Esther
D'Alessandro, Elisa
Rebolleda, Gema
Rodriguez‐Agirretxe, Iñaki
Canut, Maribel
Rodriguez‐Calvo, Pedro P. - Other Names:
- Schargel K. investigator.
Parera A. investigator.
Sangtam T. investigator.
Muñoz‐Negrete F. J. investigator.
Eder F. investigator.
Kudsieh B. investigator.
Rodriguez‐Uña I. investigator. - Abstract:
- Abstract: Purpose: To compare the supraciliary versus intrascleral implantation of the hema implant (Esnoper V‐2000) in terms of the efficacy and safety in nonpenetrating deep sclerectomy (NPDS). Patients and methods: Prospective, randomized, unmasked, competitive and multicenter clinical trial. Eighty‐three eyes from 83 patients suffering from open‐angle glaucoma (40 males, 43 females) were enrolled and followed up for 12 months. Main outcome measures were best‐corrected visual acuity (BCVA), intraocular pressure (IOP), perimetry (mean defect, MD and Visual Field Index, VFI), pachymetry, number of antiglaucoma medications and analysis of blebs according Moorfields Bleb Grading. Results: The IOP was significantly reduced in both groups from 23.74 ± 6.9 mmHg (implant sutured to the sclera, group 1) and 23.46 ± 6.47 mmHg (implant placed in the suprachoroidal space, group 2) to 15.43 ± 4.27 mmHg (p < 0.001) and 14.62 ± 3.64 mmHg (p < 0.001), respectively. There were no statistically significant differences in mean IOP values between the groups a year after the surgery (p = 0.581). BCVA did not show statistical differences in comparison with baseline (p = 0.09, group 1; p = 0.42, group 2). The mean number of antiglaucoma medications was reduced in both groups from 2.58 ± 0.04 and 2.68 ± 0.02 before the surgery to 0.32 ± 0.76 and 0.24 ± 0.66 after surgery. Conclusion: Nonpenetrating deep sclerectomy using hema implant (Esnoper V‐2000) is safe and effective regardless of theAbstract: Purpose: To compare the supraciliary versus intrascleral implantation of the hema implant (Esnoper V‐2000) in terms of the efficacy and safety in nonpenetrating deep sclerectomy (NPDS). Patients and methods: Prospective, randomized, unmasked, competitive and multicenter clinical trial. Eighty‐three eyes from 83 patients suffering from open‐angle glaucoma (40 males, 43 females) were enrolled and followed up for 12 months. Main outcome measures were best‐corrected visual acuity (BCVA), intraocular pressure (IOP), perimetry (mean defect, MD and Visual Field Index, VFI), pachymetry, number of antiglaucoma medications and analysis of blebs according Moorfields Bleb Grading. Results: The IOP was significantly reduced in both groups from 23.74 ± 6.9 mmHg (implant sutured to the sclera, group 1) and 23.46 ± 6.47 mmHg (implant placed in the suprachoroidal space, group 2) to 15.43 ± 4.27 mmHg (p < 0.001) and 14.62 ± 3.64 mmHg (p < 0.001), respectively. There were no statistically significant differences in mean IOP values between the groups a year after the surgery (p = 0.581). BCVA did not show statistical differences in comparison with baseline (p = 0.09, group 1; p = 0.42, group 2). The mean number of antiglaucoma medications was reduced in both groups from 2.58 ± 0.04 and 2.68 ± 0.02 before the surgery to 0.32 ± 0.76 and 0.24 ± 0.66 after surgery. Conclusion: Nonpenetrating deep sclerectomy using hema implant (Esnoper V‐2000) is safe and effective regardless of the positioning of the implant. We achieved IOP decrease and reduction in antiglaucoma medications during the first year after surgery without significant differences between both techniques. … (more)
- Is Part Of:
- Acta ophthalmologica. Volume 96:Issue 7(2018)
- Journal:
- Acta ophthalmologica
- Issue:
- Volume 96:Issue 7(2018)
- Issue Display:
- Volume 96, Issue 7 (2018)
- Year:
- 2018
- Volume:
- 96
- Issue:
- 7
- Issue Sort Value:
- 2018-0096-0007-0000
- Page Start:
- e852
- Page End:
- e858
- Publication Date:
- 2018-05-31
- Subjects:
- Esnoper V‐2000 -- glaucoma -- nonpenetrating deep sclerectomy -- supraciliary surgery
Ophthalmology -- Periodicals
617.7005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1755-3768 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/aos.13749 ↗
- Languages:
- English
- ISSNs:
- 1755-375X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0641.750500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8791.xml