Global Post-Market Clinical Follow-up of the Treovance Stent-Graft for Endovascular Aneurysm Repair: One-Year Results From the RATIONALE Registry. (December 2018)
- Record Type:
- Journal Article
- Title:
- Global Post-Market Clinical Follow-up of the Treovance Stent-Graft for Endovascular Aneurysm Repair: One-Year Results From the RATIONALE Registry. (December 2018)
- Main Title:
- Global Post-Market Clinical Follow-up of the Treovance Stent-Graft for Endovascular Aneurysm Repair: One-Year Results From the RATIONALE Registry
- Authors:
- Uberoi, Raman
Setacci, Carlo
Lescan, Mario
Lorido, Antonio
Murray, David
Szeberin, Zoltán
Zubilewicz, Tomasz
Riambau, Vincent
Chartrungsan, Angsu
Tessarek, Jörg - Other Names:
- Iłżecki Marek non-byline-author.
Gortz Hartmuth non-byline-author.
Thenholt Matthias non-byline-author.
Fattoum Maher non-byline-author.
Buz Semih non-byline-author.
Cao Piergiorgio non-byline-author.
Benevento Domenico non-byline-author.
Palasciano Giancarlo non-byline-author.
Abdallah Feras non-byline-author.
Boyle John non-byline-author.
Llagostera Pujol S. non-byline-author.
Esteban Carlos non-byline-author.
Mosquera Nilo non-byline-author.
Sanus Enrique Aracil non-byline-author.
Negreira Ignacio Iglesias non-byline-author.
Raymakers J.T.F.J. non-byline-author.
van Herwaarden Joost non-byline-author.
Pitoulias Georgios non-byline-author.
Kratimenos Theodoros non-byline-author.
Wahlgren Carl Magnus non-byline-author.
Forssell Claes non-byline-author.
Fulton Greg non-byline-author.
Lonn Lars non-byline-author.
Pedersen Gustav non-byline-author.
Vergara Jorge non-byline-author.
Silva Manuel Espindola non-byline-author.
Cheng Stephen Wing-Keung non-byline-author.
Anh Phan Minh non-byline-author.
Calderas Carlos David non-byline-author.
Bohan Patrick non-byline-author. - Abstract:
- Purpose: To evaluate the safety and performance of the Treovance stent-graft. Methods: The global, multicenter RATIONALE registry ( ClinicalTrials.gov ; identifier NCT03449875) prospectively enrolled 202 patients (mean age 73.0±7.8 years; 187 men) with abdominal aortic aneurysms (AAA) suitable for endovascular aneurysm repair (EVAR) using the Treovance. The composite primary safety endpoint was site-reported all-cause mortality and major morbidity. The primary efficacy outcome was clinical success. Further outcomes evaluated included technical success; stent-graft migration, patency, and integrity; endoleak; and aneurysm size changes. Results: Technical success was 96% (194/202); 8 patients had unresolved type I endoleaks at the end of the procedure. There was no 30-day mortality and 1% major morbidity (1 myocardial infarction and 1 bowel ischemia). Clinical success at 1 year was confirmed in 194 (96%) patients; 6 of 8 patients had new/persistent endoleaks and 2 had aneurysm expansion without identified endoleak. A total of 8 (4%) reinterventions were required during the mean 13.7±3.1 months of follow-up (median 12.8). At 1 year, the Kaplan-Meier estimate for freedom from reintervention was 95.6% (95% CI 91.4% to 97.8%). Other estimates were 95.5% (95% CI 91.7% to 97.6%) for freedom from endoleak type I/III and 97.4% (95% CI 94.2% to 98.9%) for freedom from aneurysm expansion. Thirteen (6.4%) patients died; no death was aneurysm related. Conclusion: The RATIONALE registryPurpose: To evaluate the safety and performance of the Treovance stent-graft. Methods: The global, multicenter RATIONALE registry ( ClinicalTrials.gov ; identifier NCT03449875) prospectively enrolled 202 patients (mean age 73.0±7.8 years; 187 men) with abdominal aortic aneurysms (AAA) suitable for endovascular aneurysm repair (EVAR) using the Treovance. The composite primary safety endpoint was site-reported all-cause mortality and major morbidity. The primary efficacy outcome was clinical success. Further outcomes evaluated included technical success; stent-graft migration, patency, and integrity; endoleak; and aneurysm size changes. Results: Technical success was 96% (194/202); 8 patients had unresolved type I endoleaks at the end of the procedure. There was no 30-day mortality and 1% major morbidity (1 myocardial infarction and 1 bowel ischemia). Clinical success at 1 year was confirmed in 194 (96%) patients; 6 of 8 patients had new/persistent endoleaks and 2 had aneurysm expansion without identified endoleak. A total of 8 (4%) reinterventions were required during the mean 13.7±3.1 months of follow-up (median 12.8). At 1 year, the Kaplan-Meier estimate for freedom from reintervention was 95.6% (95% CI 91.4% to 97.8%). Other estimates were 95.5% (95% CI 91.7% to 97.6%) for freedom from endoleak type I/III and 97.4% (95% CI 94.2% to 98.9%) for freedom from aneurysm expansion. Thirteen (6.4%) patients died; no death was aneurysm related. Conclusion: The RATIONALE registry showed favorable safety and clinical performance of the Treovance stent-graft for the treatment of infrarenal AAAs in a real-world setting. … (more)
- Is Part Of:
- Journal of endovascular therapy. Volume 25:Number 6(2018:Dec.)
- Journal:
- Journal of endovascular therapy
- Issue:
- Volume 25:Number 6(2018:Dec.)
- Issue Display:
- Volume 25, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 25
- Issue:
- 6
- Issue Sort Value:
- 2018-0025-0006-0000
- Page Start:
- 726
- Page End:
- 734
- Publication Date:
- 2018-12
- Subjects:
- abdominal aortic aneurysm -- endograft -- endoleak -- endovascular aneurysm repair -- registry -- occlusion -- mortality -- reintervention -- stent-graft
Blood-vessels -- Endoscopic surgery -- Periodicals
Angioscopy -- Periodicals
Intravenous catheterization -- Periodicals
Peripheral vascular diseases -- Treatment -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioscopy -- Periodicals
Catheterization, Peripheral -- Periodicals
Peripheral Vascular Diseases -- therapy -- Periodicals
Angioscopie
Maladies vasculaires périphériques
617.413 - Journal URLs:
- http://jet.sagepub.com/ ↗
http://www.jevt.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/1526602818803939 ↗
- Languages:
- English
- ISSNs:
- 1526-6028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8784.xml