Dependence of apparent diffusion coefficient measurement on diffusion gradient direction and spatial position – A quality assurance intercomparison study of forty-four scanners for quantitative diffusion-weighted imaging. (November 2018)
- Record Type:
- Journal Article
- Title:
- Dependence of apparent diffusion coefficient measurement on diffusion gradient direction and spatial position – A quality assurance intercomparison study of forty-four scanners for quantitative diffusion-weighted imaging. (November 2018)
- Main Title:
- Dependence of apparent diffusion coefficient measurement on diffusion gradient direction and spatial position – A quality assurance intercomparison study of forty-four scanners for quantitative diffusion-weighted imaging
- Authors:
- Fedeli, Luca
Belli, Giacomo
Ciccarone, Antonio
Coniglio, Angela
Esposito, Marco
Giannelli, Marco
Mazzoni, Lorenzo Nicola
Nocetti, Luca
Sghedoni, Roberto
Tarducci, Roberto
Altabella, Luisa
Belligotti, Eleonora
Benelli, Matteo
Betti, Margherita
Caivano, Rocchina
Carni', Marco
Chiappiniello, Andrea
Cimolai, Sara
Cretti, Fabiola
Fulcheri, Christian
Gasperi, Chiara
Giacometti, Mara
Levrero, Fabrizio
Lizio, Domenico
Maieron, Marta
Marzi, Simona
Mascaro, Lorella
Mazzocchi, Silvia
Meliado', Gabriele
Morzenti, Sabrina
Noferini, Linhsia
Oberhofer, Nadia
Quattrocchi, Maria Grazia
Ricci, Alessandra
Taddeucci, Adriana
Tenori, Leonardo
Luchinat, Claudio
Gobbi, Gianni
Gori, Cesare
Busoni, Simone
… (more) - Abstract:
- Highlights: ADC inter-center assessments. ADC spatial variation across different scanners. ADC bias in LR an HF directions. ADC quality assurance protocol. Abstract: Purpose: To propose an MRI quality assurance procedure that can be used for routine controls and multi-centre comparison of different MR-scanners for quantitative diffusion-weighted imaging (DWI). Materials and methods: 44 MR-scanners with different field strengths (1 T, 1.5 T and 3 T) were included in the study. DWI acquisitions (b-value range 0–1000 s/mm 2 ), with three different orthogonal diffusion gradient directions, were performed for each MR-scanner. All DWI acquisitions were performed by using a standard spherical plastic doped water phantom. Phantom solution ADC value and its dependence with temperature was measured using a DOSY sequence on a 600 MHz NMR spectrometer. Apparent diffusion coefficient (ADC) along each diffusion gradient direction and mean ADC were estimated, both at magnet isocentre and in six different position 50 mm away from isocentre, along positive and negative AP, RL and HF directions. Results: A good agreement was found between the nominal and measured mean ADC at isocentre: more than 90% of mean ADC measurements were within 5% from the nominal value, and the highest deviation was 11.3%. Away from isocentre, the effect of the diffusion gradient direction on ADC estimation was larger than 5% in 47% of included scanners and a spatial non uniformity larger than 5% was reported in 13%Highlights: ADC inter-center assessments. ADC spatial variation across different scanners. ADC bias in LR an HF directions. ADC quality assurance protocol. Abstract: Purpose: To propose an MRI quality assurance procedure that can be used for routine controls and multi-centre comparison of different MR-scanners for quantitative diffusion-weighted imaging (DWI). Materials and methods: 44 MR-scanners with different field strengths (1 T, 1.5 T and 3 T) were included in the study. DWI acquisitions (b-value range 0–1000 s/mm 2 ), with three different orthogonal diffusion gradient directions, were performed for each MR-scanner. All DWI acquisitions were performed by using a standard spherical plastic doped water phantom. Phantom solution ADC value and its dependence with temperature was measured using a DOSY sequence on a 600 MHz NMR spectrometer. Apparent diffusion coefficient (ADC) along each diffusion gradient direction and mean ADC were estimated, both at magnet isocentre and in six different position 50 mm away from isocentre, along positive and negative AP, RL and HF directions. Results: A good agreement was found between the nominal and measured mean ADC at isocentre: more than 90% of mean ADC measurements were within 5% from the nominal value, and the highest deviation was 11.3%. Away from isocentre, the effect of the diffusion gradient direction on ADC estimation was larger than 5% in 47% of included scanners and a spatial non uniformity larger than 5% was reported in 13% of centres. Conclusion: ADC accuracy and spatial uniformity can vary appreciably depending on MR scanner model, sequence implementation (i.e. gradient diffusion direction) and hardware characteristics. The DWI quality assurance protocol proposed in this study can be employed in order to assess the accuracy and spatial uniformity of estimated ADC values, in single- as well as multi-centre studies. … (more)
- Is Part Of:
- Physica medica. Volume 55(2018)
- Journal:
- Physica medica
- Issue:
- Volume 55(2018)
- Issue Display:
- Volume 55, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 55
- Issue:
- 2018
- Issue Sort Value:
- 2018-0055-2018-0000
- Page Start:
- 135
- Page End:
- 141
- Publication Date:
- 2018-11
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.09.007 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8750.xml