Normalized glandular dose coefficients in mammography, digital breast tomosynthesis and dedicated breast CT. (November 2018)
- Record Type:
- Journal Article
- Title:
- Normalized glandular dose coefficients in mammography, digital breast tomosynthesis and dedicated breast CT. (November 2018)
- Main Title:
- Normalized glandular dose coefficients in mammography, digital breast tomosynthesis and dedicated breast CT
- Authors:
- Sarno, A.
Mettivier, G.
Di Lillo, F.
Tucciariello, R.M.
Bliznakova, K.
Russo, P. - Abstract:
- Highlights: Modeling a breast compressed in MLO view instead of in CC view does not produce any significant differences in MGD estimates. Skin model presents a noticeable influence on T-factor in DBT. Correction factor for taking into account the ion-chamber model in MGD estimates in BCT was calculated. Abstract: Purpose: To provide mean glandular dose (MGD) estimates via Monte Carlo (MC) simulations as a function of the breast models and scan parameters in mammography, digital breast tomosynthesis (DBT) and dedicated breast CT (BCT). Methods: The MC code was based on GEANT4 toolkit. The simulated compressed breast was either a cylinder with a semi-circular section or ad hoc shaped for oblique view (MLO). In DBT we studied the influence of breast models and exam parameters on the T-factors (i.e. the conversion factor for the calculation of the MGD in DBT from that for a 0-degree projection), and in BCT we investigated the influence on the MGD estimates of the ion chamber volume used for the air kerma measurements. Results: In mammography, a model representative of a breast undergoing an MLO view exam did not produce substantial differences (0.4%) in MGD estimates, when compared to a conventional cranio-caudal (CC) view breast model. The beam half value layer did not present a significant influence on T-factors in DBT (<0.8%), while the skin model presented significant influence on MGD estimates (up to 3.3% at 30 degrees scan angle), increasing for larger scan angles. WeHighlights: Modeling a breast compressed in MLO view instead of in CC view does not produce any significant differences in MGD estimates. Skin model presents a noticeable influence on T-factor in DBT. Correction factor for taking into account the ion-chamber model in MGD estimates in BCT was calculated. Abstract: Purpose: To provide mean glandular dose (MGD) estimates via Monte Carlo (MC) simulations as a function of the breast models and scan parameters in mammography, digital breast tomosynthesis (DBT) and dedicated breast CT (BCT). Methods: The MC code was based on GEANT4 toolkit. The simulated compressed breast was either a cylinder with a semi-circular section or ad hoc shaped for oblique view (MLO). In DBT we studied the influence of breast models and exam parameters on the T-factors (i.e. the conversion factor for the calculation of the MGD in DBT from that for a 0-degree projection), and in BCT we investigated the influence on the MGD estimates of the ion chamber volume used for the air kerma measurements. Results: In mammography, a model representative of a breast undergoing an MLO view exam did not produce substantial differences (0.4%) in MGD estimates, when compared to a conventional cranio-caudal (CC) view breast model. The beam half value layer did not present a significant influence on T-factors in DBT (<0.8%), while the skin model presented significant influence on MGD estimates (up to 3.3% at 30 degrees scan angle), increasing for larger scan angles. We derived a correction factor for taking into account the different ion chamber volume used in MGD estimates in BCT. Conclusions: A series of MC code modules for MGD estimates in 2D and 3D breast imaging have been developed in order to take into account the most recent advances in breast models. … (more)
- Is Part Of:
- Physica medica. Volume 55(2018)
- Journal:
- Physica medica
- Issue:
- Volume 55(2018)
- Issue Display:
- Volume 55, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 55
- Issue:
- 2018
- Issue Sort Value:
- 2018-0055-2018-0000
- Page Start:
- 142
- Page End:
- 148
- Publication Date:
- 2018-11
- Subjects:
- Breast models -- Mean glandular dose -- Mammography -- Tomosynthesis -- Breast CT
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.09.002 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8750.xml