Brachial artery blood flow dynamics during sinusoidal leg cycling exercise in humans. Issue 19 (9th October 2017)
- Record Type:
- Journal Article
- Title:
- Brachial artery blood flow dynamics during sinusoidal leg cycling exercise in humans. Issue 19 (9th October 2017)
- Main Title:
- Brachial artery blood flow dynamics during sinusoidal leg cycling exercise in humans
- Authors:
- Fukuba, Yoshiyuki
Endo, Masako Y
Kondo, Ayaka
Kikugawa, Yuka
Miura, Kohei
Kashima, Hideaki
Fujimoto, Masaki
Hayashi, Naoyuki
Fukuoka, Yoshiyuki
Koga, Shunsaku - Abstract:
- Abstract: To explore the control of the peripheral circulation of a nonworking upper limb during leg cycling exercise, blood flow (BF) dynamics in the brachial artery (BA) were determined using a sinusoidal work rate (WR) exercise. Ten healthy subjects performed upright leg cycling exercise at a constant WR for 30 min, followed by 16 min of sinusoidal WR consisting of 4‐min periods of WR fluctuating between a minimum output of 20 W and a maximum output corresponding to ventilatory threshold (VT). Throughout the protocol, pulmonary gas exchange, heart rate (HR), mean arterial blood pressure (MAP), blood velocity (BV), and cross‐sectional area of the BA, forearm skin BF (SBF), and sweating rate (SR) were measured. Each variable was fitted to a sinusoidal model with phase shift ( θ ) and amplitude (A). Nearly all variables closely fit a sinusoidal model. Variables relating to oxygen transport, such as V O2 and HR, followed the sinusoidal WR pattern with certain delays ( θ : V O2 ; 51.4 ± 4.0°, HR; 41.8 ± 5.4°, mean ± SD). Conversely, BF response in the BA was approximately in antiphase (175.1 ± 28.9°) with a relatively large A, whereas the phase of forearm SBF was dissimilar (65.8 ± 35.9°). Thus, the change of BF through a conduit artery to the nonworking upper limb appears to be the reverse when WR fluctuates during sinusoidal leg exercise, and it appears unlikely that this could be ascribed exclusively to altering the downstream circulation to forearm skin. Abstract : ThisAbstract: To explore the control of the peripheral circulation of a nonworking upper limb during leg cycling exercise, blood flow (BF) dynamics in the brachial artery (BA) were determined using a sinusoidal work rate (WR) exercise. Ten healthy subjects performed upright leg cycling exercise at a constant WR for 30 min, followed by 16 min of sinusoidal WR consisting of 4‐min periods of WR fluctuating between a minimum output of 20 W and a maximum output corresponding to ventilatory threshold (VT). Throughout the protocol, pulmonary gas exchange, heart rate (HR), mean arterial blood pressure (MAP), blood velocity (BV), and cross‐sectional area of the BA, forearm skin BF (SBF), and sweating rate (SR) were measured. Each variable was fitted to a sinusoidal model with phase shift ( θ ) and amplitude (A). Nearly all variables closely fit a sinusoidal model. Variables relating to oxygen transport, such as V O2 and HR, followed the sinusoidal WR pattern with certain delays ( θ : V O2 ; 51.4 ± 4.0°, HR; 41.8 ± 5.4°, mean ± SD). Conversely, BF response in the BA was approximately in antiphase (175.1 ± 28.9°) with a relatively large A, whereas the phase of forearm SBF was dissimilar (65.8 ± 35.9°). Thus, the change of BF through a conduit artery to the nonworking upper limb appears to be the reverse when WR fluctuates during sinusoidal leg exercise, and it appears unlikely that this could be ascribed exclusively to altering the downstream circulation to forearm skin. Abstract : This study quantified the circulatory dynamics of blood flow (BF) to an inactive upper limb during leg cycling exercise using a sinusoidal work rate forcing function. BF in the brachial artery showed a clear sinusoidal response, with ~180° phase delay following work rate fluctuation. This was not compatible with that of forearm skin BF. … (more)
- Is Part Of:
- Physiological reports. Volume 5:Issue 19(2017)
- Journal:
- Physiological reports
- Issue:
- Volume 5:Issue 19(2017)
- Issue Display:
- Volume 5, Issue 19 (2017)
- Year:
- 2017
- Volume:
- 5
- Issue:
- 19
- Issue Sort Value:
- 2017-0005-0019-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2017-10-09
- Subjects:
- Blood flow dynamics -- brachial artery -- forearm skin blood flow -- inactive limb -- sinusoidal exercise
Physiology -- Periodicals
571 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2051-817X ↗
http://physreports.physiology.org ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.14814/phy2.13456 ↗
- Languages:
- English
- ISSNs:
- 2051-817X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8747.xml