Multiple Sclerosis: Improved Detection of Active Cerebral Lesions With 3-Dimensional T1 Black-Blood Magnetic Resonance Imaging Compared With Conventional 3-Dimensional T1 GRE Imaging. Issue 1 (January 2018)
- Record Type:
- Journal Article
- Title:
- Multiple Sclerosis: Improved Detection of Active Cerebral Lesions With 3-Dimensional T1 Black-Blood Magnetic Resonance Imaging Compared With Conventional 3-Dimensional T1 GRE Imaging. Issue 1 (January 2018)
- Main Title:
- Multiple Sclerosis
- Authors:
- Sommer, Nora N.
Saam, Tobias
Coppenrath, Eva
Kooijman, Hendrik
Kümpfel, Tania
Patzig, Maximilian
Beyer, Sebastian E.
Sommer, Wieland H.
Reiser, Maximilian F.
Ertl-Wagner, Birgit
Treitl, Karla M. - Abstract:
- Abstract : Objectives: The aim of this study was to assess the diagnostic accuracy of a modified high-resolution whole-brain three-dimensional T1-weighted black-blood sequence (T1-weighted modified volumetric isotropic turbo spin echo acquisition [T1-mVISTA]) in comparison to a standard three-dimensional T1-weighted magnetization-prepared rapid gradient echo (MP-RAGE) sequence for detection of contrast-enhancing cerebral lesions in patients with relapsing-remitting multiple sclerosis (MS). Materials and Methods: After institutional review board approval and informed consent, 22 patients (8 men; aged 31.0 ± 9.2 years) with relapsing-remitting MS were included in this monocentric prospective cohort study. Contrast-enhanced T1-mVISTA and MP-RAGE, both with 0.8 mm 3 resolution, were performed in all patients. In a substudy of 12 patients, T1-mVISTA was compared with a T1-mVISTA with 1.0 mm 3 resolution (T1-mVISTA_1.0). Reference lesions were defined by an experienced neuroradiologist using all available sequences and served as the criterion standard. T1-mVISTA, T1-mVISTA_1.0, and MP-RAGE sequences were read in random order 4 weeks apart. Image quality, visual contrast enhancement, contrast-to-noise-ratio (CNR), diagnostic confidence, and lesion size were assessed and compared by Wilcoxon and Mann-Whitney U tests. Results: Eleven of 22 patients displayed contrast-enhancing lesions. Visual contrast enhancement, CNR, and diagnostic confidence of contrast-enhancing MS lesions wereAbstract : Objectives: The aim of this study was to assess the diagnostic accuracy of a modified high-resolution whole-brain three-dimensional T1-weighted black-blood sequence (T1-weighted modified volumetric isotropic turbo spin echo acquisition [T1-mVISTA]) in comparison to a standard three-dimensional T1-weighted magnetization-prepared rapid gradient echo (MP-RAGE) sequence for detection of contrast-enhancing cerebral lesions in patients with relapsing-remitting multiple sclerosis (MS). Materials and Methods: After institutional review board approval and informed consent, 22 patients (8 men; aged 31.0 ± 9.2 years) with relapsing-remitting MS were included in this monocentric prospective cohort study. Contrast-enhanced T1-mVISTA and MP-RAGE, both with 0.8 mm 3 resolution, were performed in all patients. In a substudy of 12 patients, T1-mVISTA was compared with a T1-mVISTA with 1.0 mm 3 resolution (T1-mVISTA_1.0). Reference lesions were defined by an experienced neuroradiologist using all available sequences and served as the criterion standard. T1-mVISTA, T1-mVISTA_1.0, and MP-RAGE sequences were read in random order 4 weeks apart. Image quality, visual contrast enhancement, contrast-to-noise-ratio (CNR), diagnostic confidence, and lesion size were assessed and compared by Wilcoxon and Mann-Whitney U tests. Results: Eleven of 22 patients displayed contrast-enhancing lesions. Visual contrast enhancement, CNR, and diagnostic confidence of contrast-enhancing MS lesions were significantly increased in T1-mVISTA compared with MP-RAGE ( P < 0.001). Significantly more contrast-enhancing lesions were detected with T1-mVISTA than with MP-RAGE (71 vs 39, respectively; P < 0.001). With MP-RAGE, 25.6% of lesions were missed in the initial reading, whereas only 4.2% of lesions were missed with T1-mVISTA. Increase of the voxel volume from 0.8 mm to 1.0 mm isotropic in T1-mVISTA_1.0 did not affect the detectability of lesions, whereas scan time was decreased from 4:43 to 1:55 minutes. Conclusions: Three-dimensional T1-mVISTA improves the detection rates of contrast-enhancing cerebral MS lesions compared with conventional 3D MP-RAGE sequences by increasing CNR of lesions and might, therefore, be useful in patient management. … (more)
- Is Part Of:
- Investigative radiology. Volume 53:Issue 1(2018:Jan.)
- Journal:
- Investigative radiology
- Issue:
- Volume 53:Issue 1(2018:Jan.)
- Issue Display:
- Volume 53, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 53
- Issue:
- 1
- Issue Sort Value:
- 2018-0053-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-01
- Subjects:
- 3D black-blood imaging -- high resolution -- whole brain -- T1-mVISTA -- MP-RAGE -- multiple sclerosis -- cerebral lesions -- MRI
Diagnosis, Radioscopic -- Periodicals
Radiology, Medical -- Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/investigativeradiology/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLI.0000000000000410 ↗
- Languages:
- English
- ISSNs:
- 0020-9996
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4560.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8730.xml