Whole Slide Imaging Versus Microscopy for Primary Diagnosis in Surgical Pathology: A Multicenter Blinded Randomized Noninferiority Study of 1992 Cases (Pivotal Study). (January 2018)
- Record Type:
- Journal Article
- Title:
- Whole Slide Imaging Versus Microscopy for Primary Diagnosis in Surgical Pathology: A Multicenter Blinded Randomized Noninferiority Study of 1992 Cases (Pivotal Study). (January 2018)
- Main Title:
- Whole Slide Imaging Versus Microscopy for Primary Diagnosis in Surgical Pathology
- Authors:
- Mukhopadhyay, Sanjay
Feldman, Michael D.
Abels, Esther
Ashfaq, Raheela
Beltaifa, Senda
Cacciabeve, Nicolas G.
Cathro, Helen P.
Cheng, Liang
Cooper, Kumarasen
Dickey, Glenn E.
Gill, Ryan M.
Heaton, Robert P.
Kerstens, René
Lindberg, Guy M.
Malhotra, Reenu K.
Mandell, James W.
Manlucu, Ellen D.
Mills, Anne M.
Mills, Stacey E.
Moskaluk, Christopher A.
Nelis, Mischa
Patil, Deepa T.
Przybycin, Christopher G.
Reynolds, Jordan P.
Rubin, Brian P.
Saboorian, Mohammad H.
Salicru, Mauricio
Samols, Mark A.
Sturgis, Charles D.
Turner, Kevin O.
Wick, Mark R.
Yoon, Ji Y.
Zhao, Po
Taylor, Clive R.
… (more) - Abstract:
- Abstract : Most prior studies of primary diagnosis in surgical pathology using whole slide imaging (WSI) versus microscopy have focused on specific organ systems or included relatively few cases. The objective of this study was to demonstrate that WSI is noninferior to microscopy for primary diagnosis in surgical pathology. A blinded randomized noninferiority study was conducted across the entire range of surgical pathology cases (biopsies and resections, including hematoxylin and eosin, immunohistochemistry, and special stains) from 4 institutions using the original sign-out diagnosis (baseline diagnosis) as the reference standard. Cases were scanned, converted to WSI and randomized. Sixteen pathologists interpreted cases by microscopy or WSI, followed by a wash-out period of ≥4 weeks, after which cases were read by the same observers using the other modality. Major discordances were identified by an adjudication panel, and the differences between major discordance rates for both microscopy (against the reference standard) and WSI (against the reference standard) were calculated. A total of 1992 cases were included, resulting in 15, 925 reads. The major discordance rate with the reference standard diagnosis was 4.9% for WSI and 4.6% for microscopy. The difference between major discordance rates for microscopy and WSI was 0.4% (95% confidence interval, −0.30% to 1.01%). The difference in major discordance rates for WSI and microscopy was highest in endocrine pathologyAbstract : Most prior studies of primary diagnosis in surgical pathology using whole slide imaging (WSI) versus microscopy have focused on specific organ systems or included relatively few cases. The objective of this study was to demonstrate that WSI is noninferior to microscopy for primary diagnosis in surgical pathology. A blinded randomized noninferiority study was conducted across the entire range of surgical pathology cases (biopsies and resections, including hematoxylin and eosin, immunohistochemistry, and special stains) from 4 institutions using the original sign-out diagnosis (baseline diagnosis) as the reference standard. Cases were scanned, converted to WSI and randomized. Sixteen pathologists interpreted cases by microscopy or WSI, followed by a wash-out period of ≥4 weeks, after which cases were read by the same observers using the other modality. Major discordances were identified by an adjudication panel, and the differences between major discordance rates for both microscopy (against the reference standard) and WSI (against the reference standard) were calculated. A total of 1992 cases were included, resulting in 15, 925 reads. The major discordance rate with the reference standard diagnosis was 4.9% for WSI and 4.6% for microscopy. The difference between major discordance rates for microscopy and WSI was 0.4% (95% confidence interval, −0.30% to 1.01%). The difference in major discordance rates for WSI and microscopy was highest in endocrine pathology (1.8%), neoplastic kidney pathology (1.5%), urinary bladder pathology (1.3%), and gynecologic pathology (1.2%). Detailed analysis of these cases revealed no instances where interpretation by WSI was consistently inaccurate compared with microscopy for multiple observers. We conclude that WSI is noninferior to microscopy for primary diagnosis in surgical pathology, including biopsies and resections stained with hematoxylin and eosin, immunohistochemistry and special stains. This conclusion is valid across a wide variety of organ systems and specimen types. … (more)
- Is Part Of:
- American journal of surgical pathology. Volume 42:Number 1(2018)
- Journal:
- American journal of surgical pathology
- Issue:
- Volume 42:Number 1(2018)
- Issue Display:
- Volume 42, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 42
- Issue:
- 1
- Issue Sort Value:
- 2018-0042-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-01
- Subjects:
- whole slide imaging -- microscopy -- surgical pathology -- digital imaging -- pathology -- primary diagnosis -- noninferiority trial
Pathology, Surgical -- Periodicals
617.0705 - Journal URLs:
- http://journals.lww.com/ajsp/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/PAS.0000000000000948 ↗
- Languages:
- English
- ISSNs:
- 0147-5185
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0838.520000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8725.xml