Flip angle optimization for balanced SSFP: Cardiac cine imaging following the application of standard extracellular contrast agent (gadobutrol). Issue 1 (21st April 2017)
- Record Type:
- Journal Article
- Title:
- Flip angle optimization for balanced SSFP: Cardiac cine imaging following the application of standard extracellular contrast agent (gadobutrol). Issue 1 (21st April 2017)
- Main Title:
- Flip angle optimization for balanced SSFP: Cardiac cine imaging following the application of standard extracellular contrast agent (gadobutrol)
- Authors:
- Kuetting, Daniel L.R.
Dabir, Darius
Luetkens, Julian
Feisst, Andreas
Homsi, Rami
Thomas, Daniel
Schild, Hans H.
Sprinkart, Alois M. - Abstract:
- Abstract : Purpose: To investigate the effect of the flip angle (FA) on the blood‐myocardium contrast and to define the FA leading to highest image quality in contrast‐enhanced balanced steady‐state free precession (bSSFP) images. bSSFP images provide excellent contrast between myocardium and blood with high signal‐to‐noise and contrast‐to‐noise ratios (SNR, CNR). In clinical practice, bSSFP images are typically acquired following the injection of extracellular contrast agents (ECAs), although ECAs decrease the blood‐myocardium contrast. Materials and Methods: First, a theoretical optimization was performed to determine the FA that maximizes CNR in bSSFP imaging 2–20 minutes after application of ECA. Second signal‐ratios, contrast, SNR, and CNR were assessed in vivo in 25 patients in bSSFP images at 1.5T acquired before (FA = 50°) and 10–15 minutes after (FAs = 50°, 80°, 90°, 100°) application of a double‐dose contrast agent. Image quality was assessed by two readers. Results: Simulations yielded FAs in the range of 85–100° for optimal CNR in contrast‐enhanced images. In vivo comparison of conventionally acquired cine images (FA 50°) showed an increase in CNR between blood and myocardium by 57% in diastole and 78% in systole in adapted contrast‐enhanced bSSFP images (FA 100°). Contrast‐enhanced images with an FA of 100° were rated highest in image quality assessment. Conclusion: By means of FA adaptation a similar blood‐myocardium contrast can be achieved inAbstract : Purpose: To investigate the effect of the flip angle (FA) on the blood‐myocardium contrast and to define the FA leading to highest image quality in contrast‐enhanced balanced steady‐state free precession (bSSFP) images. bSSFP images provide excellent contrast between myocardium and blood with high signal‐to‐noise and contrast‐to‐noise ratios (SNR, CNR). In clinical practice, bSSFP images are typically acquired following the injection of extracellular contrast agents (ECAs), although ECAs decrease the blood‐myocardium contrast. Materials and Methods: First, a theoretical optimization was performed to determine the FA that maximizes CNR in bSSFP imaging 2–20 minutes after application of ECA. Second signal‐ratios, contrast, SNR, and CNR were assessed in vivo in 25 patients in bSSFP images at 1.5T acquired before (FA = 50°) and 10–15 minutes after (FAs = 50°, 80°, 90°, 100°) application of a double‐dose contrast agent. Image quality was assessed by two readers. Results: Simulations yielded FAs in the range of 85–100° for optimal CNR in contrast‐enhanced images. In vivo comparison of conventionally acquired cine images (FA 50°) showed an increase in CNR between blood and myocardium by 57% in diastole and 78% in systole in adapted contrast‐enhanced bSSFP images (FA 100°). Contrast‐enhanced images with an FA of 100° were rated highest in image quality assessment. Conclusion: By means of FA adaptation a similar blood‐myocardium contrast can be achieved in contrast‐enhanced bSSFP as in unenhanced bSSFP imaging with an increase in CNR. Level of Evidence: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:255–261. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 47:Issue 1(2018)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 47:Issue 1(2018)
- Issue Display:
- Volume 47, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 47
- Issue:
- 1
- Issue Sort Value:
- 2018-0047-0001-0000
- Page Start:
- 255
- Page End:
- 261
- Publication Date:
- 2017-04-21
- Subjects:
- bSSFP -- contrast‐enhanced -- contrast optimization -- gadobutrol
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25728 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8731.xml