Additional values of high‐resolution gadoxetic acid‐enhanced MR cholangiography for evaluating the biliary anatomy of living liver donors: Comparison with T2‐weighted MR cholangiography and conventional gadoxetic acid‐enhanced MR cholangiography. Issue 1 (11th April 2017)
- Record Type:
- Journal Article
- Title:
- Additional values of high‐resolution gadoxetic acid‐enhanced MR cholangiography for evaluating the biliary anatomy of living liver donors: Comparison with T2‐weighted MR cholangiography and conventional gadoxetic acid‐enhanced MR cholangiography. Issue 1 (11th April 2017)
- Main Title:
- Additional values of high‐resolution gadoxetic acid‐enhanced MR cholangiography for evaluating the biliary anatomy of living liver donors: Comparison with T2‐weighted MR cholangiography and conventional gadoxetic acid‐enhanced MR cholangiography
- Authors:
- Kang, Hyo‐Jin
Lee, Jeong Min
Yoon, Jeong Hee
Joo, Ijin
Chang, Won
Suh, Kyung‐Suk
Lee, Kwang‐Woong
Yi, Nam‐Joon
Han, Joon Koo - Abstract:
- Abstract : Purpose: To determine the incremental value of small field of view (sFOV) high‐resolution (HR) gadoxetic acid‐enhanced 3D T 1 ‐weighted (W) magnetic resonance cholangiography (MRC) for evaluating the biliary anatomy of potential living donors by comparing it to T 2 W‐MRC. Materials and Methods: In all, 73 living donor candidates underwent gadoxetic acid‐enhanced MRI (3.0T) including three kinds of MRCs: 3D multislice T 2 W‐MRC, regular FOV (rFOV) (380 × 380mm, resolution 1.0 × 1.2 × 3.0 mm) 3D T 1 W‐MRC, and sFOV (256 × 208 mm, resolution 1.0 × 1.0 × 1.0 mm) HR‐ T 1 W‐MRC. Three radiologists reviewed the image sets for the visibility of segmental intrahepatic bile ducts (BDs), biliary anatomy with its confidence level, and expected number of BD openings at right hemihepatectomy. Results: Compared to T 2 W‐MRC alone, the combination of sFOV HR‐ T 1 W‐MRC and T 2 W‐MRC (s T 1 W‐HR set) yielded significantly improved BD visibility scores ( P < 0.01) and confidence levels for biliary anatomy ( P < 0.01). Compared to the r T 1 W set (rFOV T 1 W‐MRC with T 2 W MRC), the sFOV HR set showed significantly increased caudate duct visibility ( P < 0.001). In the case of T 2 W‐MRC presenting subdiagnostic image quality, the addition of sFOV HR T 1 W‐MRC provided diagnostically acceptable image visibility (53.8∼90%) to all reviewers. The addition of sFOV HR‐ T 1 W‐MRC resulted in a significantly higher consistency with the operative record and expected number of BD openingsAbstract : Purpose: To determine the incremental value of small field of view (sFOV) high‐resolution (HR) gadoxetic acid‐enhanced 3D T 1 ‐weighted (W) magnetic resonance cholangiography (MRC) for evaluating the biliary anatomy of potential living donors by comparing it to T 2 W‐MRC. Materials and Methods: In all, 73 living donor candidates underwent gadoxetic acid‐enhanced MRI (3.0T) including three kinds of MRCs: 3D multislice T 2 W‐MRC, regular FOV (rFOV) (380 × 380mm, resolution 1.0 × 1.2 × 3.0 mm) 3D T 1 W‐MRC, and sFOV (256 × 208 mm, resolution 1.0 × 1.0 × 1.0 mm) HR‐ T 1 W‐MRC. Three radiologists reviewed the image sets for the visibility of segmental intrahepatic bile ducts (BDs), biliary anatomy with its confidence level, and expected number of BD openings at right hemihepatectomy. Results: Compared to T 2 W‐MRC alone, the combination of sFOV HR‐ T 1 W‐MRC and T 2 W‐MRC (s T 1 W‐HR set) yielded significantly improved BD visibility scores ( P < 0.01) and confidence levels for biliary anatomy ( P < 0.01). Compared to the r T 1 W set (rFOV T 1 W‐MRC with T 2 W MRC), the sFOV HR set showed significantly increased caudate duct visibility ( P < 0.001). In the case of T 2 W‐MRC presenting subdiagnostic image quality, the addition of sFOV HR T 1 W‐MRC provided diagnostically acceptable image visibility (53.8∼90%) to all reviewers. The addition of sFOV HR‐ T 1 W‐MRC resulted in a significantly higher consistency with the operative record and expected number of BD openings than did T 2 W‐MRC alone ( P < 0.05 in all reviewers) or rFOV set ( P < 0.05 in one reviewer) with excellent interobserver agreement of both T 1 W‐MRC sets. Conclusion: The combination of sFOV HR‐ T 1 W‐MRC and T 2 W‐MRC significantly improved BD visibility and confidence levels for biliary anatomy compared to T 2 W‐MRC alone, thereby allowing accurate biliary anatomy assessment in most patients with subdiagnostic T 2 W‐MRC images. Level of Evidence: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:152–159. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 47:Issue 1(2018)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 47:Issue 1(2018)
- Issue Display:
- Volume 47, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 47
- Issue:
- 1
- Issue Sort Value:
- 2018-0047-0001-0000
- Page Start:
- 152
- Page End:
- 159
- Publication Date:
- 2017-04-11
- Subjects:
- magnetic resonance cholangiography -- living liver donor -- liver transplantation -- bile duct anatomy -- small FOV -- high resolution T1W‐MRC
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25725 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8731.xml