Morphologic Differences Observed by Scanning Electron Microscopy According to the Reason for Pseudophakic IOL Explantation. Issue 5 (September 2015)
- Record Type:
- Journal Article
- Title:
- Morphologic Differences Observed by Scanning Electron Microscopy According to the Reason for Pseudophakic IOL Explantation. Issue 5 (September 2015)
- Main Title:
- Morphologic Differences Observed by Scanning Electron Microscopy According to the Reason for Pseudophakic IOL Explantation
- Authors:
- Fernández-Buenaga, Roberto
Alio, Jorge L.
Ramírez, José M.
Salazar, Juan José
Prause, Jan Ulrik
Ramírez, Ana I.
De Hoz, Rosa
Rojas, Blanca
Triviño, Alberto - Abstract:
- Purpose: To compare variations in surface morphology, as studied by scanning electron microscopy (SEM), of explanted intraocular lenses (IOLs) concerning the cause leading to the explantation surgery. Methods: In this prospective multicenter study, explanted IOLs were analyzed by SEM and energy-dispersive X-ray spectroscopy. The IOLs were explanted in the centers of the research group from 2006 to 2012. The primary procedure was phacoemulsification in all cases. Results: The study evaluated 40 IOLs. The main causes for explantation were IOL dislocation, refractive error, and IOL opacification. Those explanted due to dislocation demonstrated calcifications in 8 lenses (50%), salt precipitates in 6 cases (37.5%), and erythrocytes and fibrosis/fibroblasts in 2 cases (12.5%). In the refractive error cases, the SEM showed proteins in 5 cases (45.5%) and salt precipitates in 4 lenses (36.4%). In IOL opacification, the findings were calcifications in 2 of the 3 lenses (66.6%) and proteins in 2 lenses (66.6%). Conclusions: A marked variation in surface changes was observed by SEM. Findings did not correlate with cause for explantation. Scanning electron microscopy is a useful tool that provides exclusive information regarding the IOL biotolerance and its interactions with surrounding tissues.
- Is Part Of:
- European journal of ophthalmology. Volume 25:Issue 5(2015)
- Journal:
- European journal of ophthalmology
- Issue:
- Volume 25:Issue 5(2015)
- Issue Display:
- Volume 25, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 25
- Issue:
- 5
- Issue Sort Value:
- 2015-0025-0005-0000
- Page Start:
- 426
- Page End:
- 430
- Publication Date:
- 2015-09
- Subjects:
- IOL biocompatibility -- IOL deposits -- IOL explantation -- Scanning electron microscopy
Ophthalmology -- Periodicals
Eye -- Diseases -- Periodicals
617.7005 - Journal URLs:
- http://www.uk.sagepub.com/home.nav ↗
http://www.eur-j-ophthalmol.com/Home/Index ↗
http://journals.sagepub.com/home/ejo ↗ - DOI:
- 10.5301/ejo.5000615 ↗
- Languages:
- English
- ISSNs:
- 1120-6721
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8694.xml