Malignant Glaucoma-Like Syndrome after EX-PRESS Filtration Surgery. Issue 4 (July 2015)
- Record Type:
- Journal Article
- Title:
- Malignant Glaucoma-Like Syndrome after EX-PRESS Filtration Surgery. Issue 4 (July 2015)
- Main Title:
- Malignant Glaucoma-Like Syndrome after EX-PRESS Filtration Surgery
- Authors:
- Casini, Giamberto
Loiudice, Pasquale
Martinelli, Paolo
Nasini, Francesco
Nardi, Marco - Abstract:
- Purpose: To report a case of postsurgical shallow anterior chamber and elevated intraocular pressure (IOP) simulating malignant glaucoma. Methods: A 20-year-old woman underwent EX-PRESS® device implant for treatment of primary open-angle glaucoma. Results: Postoperative examination showed a shallow anterior chamber, the EX-PRESS® device embedded in the iris, an IOP of 28 mm Hg, and an annular detachment of the choroid ciliary body, suggesting hyperfiltration followed by EX-PRESS® blockage. The anterior chamber was restored using an ophthalmic viscoelastic and an additional suture was applied ensuring the scleral flap. The IOP progressively decreased in the following days and the anterior chamber remained deep and stable. New ocular ultrasonography showed complete resolution of the ciliary body detachment 15 days after surgery. Conclusions: After glaucoma surgery, not every patient with shallow anterior chamber and normal or high IOP necessarily has a ciliary block glaucoma. In our case, hyperfiltration led to choroidal expansion, shallow anterior chamber, obstruction of the EX-PRESS®, and secondary blockage of outflow. The differential diagnosis is important in order to avoid further invasive procedures (i.e., lensectomy or vitrectomy).
- Is Part Of:
- European journal of ophthalmology. Volume 25:Issue 4(2015)
- Journal:
- European journal of ophthalmology
- Issue:
- Volume 25:Issue 4(2015)
- Issue Display:
- Volume 25, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 25
- Issue:
- 4
- Issue Sort Value:
- 2015-0025-0004-0000
- Page Start:
- e42
- Page End:
- e45
- Publication Date:
- 2015-07
- Subjects:
- Choroidal detachment -- Ciliary body detachment -- EX-PRESS® device -- Malignant glaucoma
Ophthalmology -- Periodicals
Eye -- Diseases -- Periodicals
617.7005 - Journal URLs:
- http://www.uk.sagepub.com/home.nav ↗
http://www.eur-j-ophthalmol.com/Home/Index ↗
http://journals.sagepub.com/home/ejo ↗ - DOI:
- 10.5301/ejo.5000588 ↗
- Languages:
- English
- ISSNs:
- 1120-6721
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8706.xml