The Evaluation of Aortic Diameter Changes During Long-Term Follow-Up After Endovascular Treatment of Acute Blunt Traumatic Thoracic Aortic Injuries. (July 2018)
- Record Type:
- Journal Article
- Title:
- The Evaluation of Aortic Diameter Changes During Long-Term Follow-Up After Endovascular Treatment of Acute Blunt Traumatic Thoracic Aortic Injuries. (July 2018)
- Main Title:
- The Evaluation of Aortic Diameter Changes During Long-Term Follow-Up After Endovascular Treatment of Acute Blunt Traumatic Thoracic Aortic Injuries
- Authors:
- Fontana, Federico
Macchi, Edoardo
Piacentino, Filippo
Cardim, Larissa Nocchi
Marchi, Giuseppe De
Barbosa, Fabiane
Piffaretti, Gabriele
Novario, Raffaele
Rampoldi, Antonio Gaetano
Fugazzola, Carlo - Abstract:
- Purpose: To evaluate the variations in aortic diameters and long-term results in patients who underwent thoracic endovascular aortic repair (TEVAR) for acute blunt traumatic thoracic aortic injuries (BTTAIs). Materials and Methods: We retrospectively evaluated 23 patients with a mean age of 39 years (range: 17-74 years) who underwent TEVAR for BTTAI between October 2000 and November 2014. All of the patients underwent computed tomography angiography (CTA) before hospital discharge as a baseline imaging for the subsequent follow-up examinations. The technical success, overall survival, and complications were evaluated. Furthermore, the aortic diameters outside of the stent-graft (1 cm proximal and 1 cm distal to the stent-graft) and the aortic diameters within the stent-graft (2 cm distal to the proximal end and 2 cm proximal to the distal end) were assessed. The diameters at baseline on CTA were compared with those of the latest available follow-up examination. Results: Technical success was 100% with a mean follow-up of 65.4 months (range: 12-171 months). No death was registered, and 2 (8.7%) of 23 endograft-related complications (1 stent-graft distal infolding and 1 endoleak 2 and 4 months after the procedure, respectively) were observed. An increase in aortic diameter either proximal or distal to the stent-graft (mean value 0.7 and 0.5 mm, respectively) or within the stent-graft (mean value of 0.5 mm for both proximal and distal diameters) was registered (mean follow-upPurpose: To evaluate the variations in aortic diameters and long-term results in patients who underwent thoracic endovascular aortic repair (TEVAR) for acute blunt traumatic thoracic aortic injuries (BTTAIs). Materials and Methods: We retrospectively evaluated 23 patients with a mean age of 39 years (range: 17-74 years) who underwent TEVAR for BTTAI between October 2000 and November 2014. All of the patients underwent computed tomography angiography (CTA) before hospital discharge as a baseline imaging for the subsequent follow-up examinations. The technical success, overall survival, and complications were evaluated. Furthermore, the aortic diameters outside of the stent-graft (1 cm proximal and 1 cm distal to the stent-graft) and the aortic diameters within the stent-graft (2 cm distal to the proximal end and 2 cm proximal to the distal end) were assessed. The diameters at baseline on CTA were compared with those of the latest available follow-up examination. Results: Technical success was 100% with a mean follow-up of 65.4 months (range: 12-171 months). No death was registered, and 2 (8.7%) of 23 endograft-related complications (1 stent-graft distal infolding and 1 endoleak 2 and 4 months after the procedure, respectively) were observed. An increase in aortic diameter either proximal or distal to the stent-graft (mean value 0.7 and 0.5 mm, respectively) or within the stent-graft (mean value of 0.5 mm for both proximal and distal diameters) was registered (mean follow-up at 65.4 months, range: 12-171 months). Conclusion: Aortic dilatation following TEVAR for BTTAI is minimal during long-term follow-up. Endovascular treatment represents a durable and safe option in acute BTTAIs. … (more)
- Is Part Of:
- Vascular & endovascular surgery. Volume 52:Number 5(2018)
- Journal:
- Vascular & endovascular surgery
- Issue:
- Volume 52:Number 5(2018)
- Issue Display:
- Volume 52, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 52
- Issue:
- 5
- Issue Sort Value:
- 2018-0052-0005-0000
- Page Start:
- 335
- Page End:
- 343
- Publication Date:
- 2018-07
- Subjects:
- TEVAR -- blunt traumatic thoracic aortic injury -- aortic diameters -- endovascular -- long-term follow-up
Blood-vessels -- Surgery -- Periodicals
Blood-vessels -- Endoscopic surgery -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioplasty -- Periodicals
Surgical Procedures, Minimally Invasive -- Periodicals
Vascular Diseases -- surgery -- Periodicals
Vaisseaux sanguins -- Chirurgie -- Périodiques
Vaisseaux sanguins -- Chirurgie endoscopique -- Périodiques
617.41 - Journal URLs:
- http://galenet.galegroup.com/servlet/HWRC?locIC=lcml_main ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00134449-000000000-00000 ↗
http://journals.sagepub.com/home/ves ↗
http://ves.sagepub.com ↗
http://www.sagepublications.com/ ↗ - DOI:
- 10.1177/1538574418765385 ↗
- Languages:
- English
- ISSNs:
- 1538-5744
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8666.xml