Early and mid-term results in the endovascular treatment of popliteal aneurysms with the multilayer flow modulator. (October 2018)
- Record Type:
- Journal Article
- Title:
- Early and mid-term results in the endovascular treatment of popliteal aneurysms with the multilayer flow modulator. (October 2018)
- Main Title:
- Early and mid-term results in the endovascular treatment of popliteal aneurysms with the multilayer flow modulator
- Authors:
- Ucci, Alessandro
Curci, Ruggiero
Azzarone, Matteo
Bianchini Massoni, Claudio
Bozzani, Antonio
Marcato, Carla
Marone, Enrico Maria
Perini, Paolo
Tecchio, Tiziano
Freyrie, Antonio
Argenteri, Angelo - Abstract:
- Background: The endovascular approach became an alternative to open surgical treatment of popliteal artery aneurysm over the last few years. Heparin-bonded stent-grafts have been employed for endovascular popliteal artery aneurysm repair, showing good and stable results. Only few reports about the use of multilayer flow modulator are available in literature, providing small patient series and short follow-up. The aim of this study is to report the outcomes of patients with popliteal artery aneurysm treated with the multilayer flow modulator in three Italian centres. Methods: We retrospectively analysed a series of both symptomatic and asymptomatic patients with popliteal artery aneurysm treated with the multilayer flow modulator from 2009 to 2015. Follow-up was undertaken with clinical and contrast-enhanced ultrasound examinations at 1, 6 and 12 months, and yearly thereafter. Computed tomography angiography was performed in selected cases. Primary endpoints were aneurysm sac thrombosis; freedom from sac enlargement and primary, primary-assisted and secondary patency during follow-up. Secondary endpoints were technical success, collateral vessels patency, limb salvage and aneurysm-related complications. Results: Twenty-three consecutive patients (19 males, age 72 ± 11) with 25 popliteal artery aneurysms (mean diameter 23 mm ± 1, 3 symptomatic patients) were treated with 40 multilayer flow modulators during the period of the study. Median follow-up was 22.6 ± 16.7 months.Background: The endovascular approach became an alternative to open surgical treatment of popliteal artery aneurysm over the last few years. Heparin-bonded stent-grafts have been employed for endovascular popliteal artery aneurysm repair, showing good and stable results. Only few reports about the use of multilayer flow modulator are available in literature, providing small patient series and short follow-up. The aim of this study is to report the outcomes of patients with popliteal artery aneurysm treated with the multilayer flow modulator in three Italian centres. Methods: We retrospectively analysed a series of both symptomatic and asymptomatic patients with popliteal artery aneurysm treated with the multilayer flow modulator from 2009 to 2015. Follow-up was undertaken with clinical and contrast-enhanced ultrasound examinations at 1, 6 and 12 months, and yearly thereafter. Computed tomography angiography was performed in selected cases. Primary endpoints were aneurysm sac thrombosis; freedom from sac enlargement and primary, primary-assisted and secondary patency during follow-up. Secondary endpoints were technical success, collateral vessels patency, limb salvage and aneurysm-related complications. Results: Twenty-three consecutive patients (19 males, age 72 ± 11) with 25 popliteal artery aneurysms (mean diameter 23 mm ± 1, 3 symptomatic patients) were treated with 40 multilayer flow modulators during the period of the study. Median follow-up was 22.6 ± 16.7 months. Complete aneurysm thrombosis occurred in 92.9% of cases (23/25 cases) at 18 months. Freedom from sac enlargement was 100% (25/25 cases) with 17 cases of aneurysm sac shrinkage (68%). At 1, 6, 12 and 24 months, estimated primary patency was 95.7%, 87.3%, 77% and 70.1%, respectively. At the same intervals, primary-assisted patency was 95.7%, 91.3%, 86% and 86%, respectively, and secondary patency was 100%, 95.7%, 90.3% and 90.3%, respectively. Technical success was 100%. The collateral vessels patency was 72.4%. Limb salvage was 91.4% at 24-month follow-up. One multilayer flow modulator fracture was reported in an asymptomatic patient. Conclusions: Multilayer flow modulator seems a feasible and safe solution for endovascular treatment of popliteal artery aneurysms in selected patients. … (more)
- Is Part Of:
- Vascular. Volume 26:Number 5(2018)
- Journal:
- Vascular
- Issue:
- Volume 26:Number 5(2018)
- Issue Display:
- Volume 26, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 26
- Issue:
- 5
- Issue Sort Value:
- 2018-0026-0005-0000
- Page Start:
- 556
- Page End:
- 563
- Publication Date:
- 2018-10
- Subjects:
- Endovascular -- popliteal artery -- aneurysm -- Cardiatis -- multilayer flow modulator -- endovascular popliteal artery aneurysm repair
616.13 - Journal URLs:
- http://vascular.rsmjournals.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1708538118771258 ↗
- Languages:
- English
- ISSNs:
- 1708-5381
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8674.xml