High-resolution manometry is superior to endoscopy and radiology in assessing and grading sliding hiatal hernia: A comparison with surgical in vivo evaluation. Issue 7 (August 2018)
- Record Type:
- Journal Article
- Title:
- High-resolution manometry is superior to endoscopy and radiology in assessing and grading sliding hiatal hernia: A comparison with surgical in vivo evaluation. Issue 7 (August 2018)
- Main Title:
- High-resolution manometry is superior to endoscopy and radiology in assessing and grading sliding hiatal hernia: A comparison with surgical in vivo evaluation
- Authors:
- Tolone, Salvatore
Savarino, Edoardo
Zaninotto, Giovanni
Gyawali, C Prakash
Frazzoni, Marzio
de Bortoli, Nicola
Frazzoni, Leonardo
del Genio, Gianmattia
Bodini, Giorgia
Furnari, Manuele
Savarino, Vincenzo
Docimo, Ludovico - Abstract:
- Background: Hiatal hernia is diagnosed by barium-swallow esophagogram or esophagogastroduodenoscopy, with possible suboptimal results. High-resolution manometry clearly identifies crural diaphragm and lower esophageal sphincter. Objectives: To assess the diagnostic accuracy of high-resolution manometry in detecting hiatal hernia compared to esophagogram and esophagogastroduodenoscopy, using as reference the surgical in vivo measurement. Methods: Patients were studied with esophagogram, esophagogastroduodenoscopy, high-resolution manometry and in vivo evaluation of the esophago-gastric junction. Esophago-gastric junction was classified as type I (no separation between crural diaphragm and lower esophageal sphincter); type II (≥1, ≤ 2 cm separation); type III (>2 cm). During in vivo measurement, distance between the esophago-gastric junction and crural diaphragm proximal border was recorded. Results: Surgery identified 53 hiatal hernias in 100 patients. Forty-seven percent were classified as type I esophago-gastric junction, 35% type II and 18% type III. Referenced to in vivo evaluation, high-resolution manometry showed superior diagnostic sensitivity and specificity (94.3% and 91.5%, respectively) to esophagogram and esophagogastroduodenoscopy, with 92.6% predictive value of a positive test and 93.5% predictive value of a negative test. The kappa value for high-resolution manometry and in vivo evaluation was 0.85. High-resolution manometry showed optimal sensitivity andBackground: Hiatal hernia is diagnosed by barium-swallow esophagogram or esophagogastroduodenoscopy, with possible suboptimal results. High-resolution manometry clearly identifies crural diaphragm and lower esophageal sphincter. Objectives: To assess the diagnostic accuracy of high-resolution manometry in detecting hiatal hernia compared to esophagogram and esophagogastroduodenoscopy, using as reference the surgical in vivo measurement. Methods: Patients were studied with esophagogram, esophagogastroduodenoscopy, high-resolution manometry and in vivo evaluation of the esophago-gastric junction. Esophago-gastric junction was classified as type I (no separation between crural diaphragm and lower esophageal sphincter); type II (≥1, ≤ 2 cm separation); type III (>2 cm). During in vivo measurement, distance between the esophago-gastric junction and crural diaphragm proximal border was recorded. Results: Surgery identified 53 hiatal hernias in 100 patients. Forty-seven percent were classified as type I esophago-gastric junction, 35% type II and 18% type III. Referenced to in vivo evaluation, high-resolution manometry showed superior diagnostic sensitivity and specificity (94.3% and 91.5%, respectively) to esophagogram and esophagogastroduodenoscopy, with 92.6% predictive value of a positive test and 93.5% predictive value of a negative test. The kappa value for high-resolution manometry and in vivo evaluation was 0.85. High-resolution manometry showed optimal sensitivity and specificity in detecting types I, II and III esophago-gastric junction. Conclusions: High-resolution manometry enables an accurate diagnosis of hiatal hernia and a better classification than endoscopy and radiology, reaching optimal agreement with in vivo assessment. … (more)
- Is Part Of:
- United European Gastroenterology journal. Volume 6:Issue 7(2018)
- Journal:
- United European Gastroenterology journal
- Issue:
- Volume 6:Issue 7(2018)
- Issue Display:
- Volume 6, Issue 7 (2018)
- Year:
- 2018
- Volume:
- 6
- Issue:
- 7
- Issue Sort Value:
- 2018-0006-0007-0000
- Page Start:
- 981
- Page End:
- 989
- Publication Date:
- 2018-08
- Subjects:
- Hiatal hernia -- esophagogastric junction -- high resolution manometry -- upper endoscopy -- barium esophagogram
Gastroenterology -- Periodicals
Periodicals
616.33005 - Journal URLs:
- https://onlinelibrary.wiley.com/loi/20506414 ↗
http://www.uk.sagepub.com ↗
http://ueg.sagepub.com/ ↗ - DOI:
- 10.1177/2050640618769160 ↗
- Languages:
- English
- ISSNs:
- 2050-6406
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8661.xml