Effect of Emergency Department Mattress Compressibility on Chest Compression Depth Using a Standardized Cardiopulmonary Resuscitation Board, a Slider Transfer Board, and a Flat Spine Board: A Simulation-Based Study. Issue 6 (December 2017)
- Record Type:
- Journal Article
- Title:
- Effect of Emergency Department Mattress Compressibility on Chest Compression Depth Using a Standardized Cardiopulmonary Resuscitation Board, a Slider Transfer Board, and a Flat Spine Board: A Simulation-Based Study. Issue 6 (December 2017)
- Main Title:
- Effect of Emergency Department Mattress Compressibility on Chest Compression Depth Using a Standardized Cardiopulmonary Resuscitation Board, a Slider Transfer Board, and a Flat Spine Board
- Authors:
- Cheng, Adam
Belanger, Claudia
Wan, Brandi
Davidson, Jennifer
Lin, Yiqun - Abstract:
- Abstract : Introduction: Cardiopulmonary resuscitation (CPR) performed on a mattress decreases effective chest compression depth. Using a CPR board partially attenuates mattress compressibility. We aimed to determine the effect of a CPR board, a slider transfer board, a CPR board with a slider transfer board, and a flat spine board on chest compression depth with a mannequin placed on an emergency department mattress. Methods: The study used a cross-over study design. The CPR-certified healthcare providers performed 2 minutes of compressions on a mannequin in five conditions, an emergency department mattress with: ( a ) no hard surface, ( b ) a CPR board, ( c ) a slider transfer board, ( d ) a CPR board and slider transfer board, and ( e ) a flat spine board. Compression depths were measured from two sources for each condition: ( a ) an internal device measuring sternum-to-spine compression and ( b ) an external device measuring sternum-to-spine compression plus mattress compression. The difference of the two measures (ie, depleted compression depth) was summarized and compared between conditions. Results: A total of 10, 203 individual compressions from 10 participants were analyzed. The mean depleted compression depths (percentage depletion) secondary to mattress effect were the following: 23.6 mm (29.7%) on a mattress only, 13.7 mm (19.5%) on a CPR board, 16.9 mm (23.1%) on a slider transfer board, 11.9 mm (17.3%) on a slider transfer board plus backboard, and 10.3 mmAbstract : Introduction: Cardiopulmonary resuscitation (CPR) performed on a mattress decreases effective chest compression depth. Using a CPR board partially attenuates mattress compressibility. We aimed to determine the effect of a CPR board, a slider transfer board, a CPR board with a slider transfer board, and a flat spine board on chest compression depth with a mannequin placed on an emergency department mattress. Methods: The study used a cross-over study design. The CPR-certified healthcare providers performed 2 minutes of compressions on a mannequin in five conditions, an emergency department mattress with: ( a ) no hard surface, ( b ) a CPR board, ( c ) a slider transfer board, ( d ) a CPR board and slider transfer board, and ( e ) a flat spine board. Compression depths were measured from two sources for each condition: ( a ) an internal device measuring sternum-to-spine compression and ( b ) an external device measuring sternum-to-spine compression plus mattress compression. The difference of the two measures (ie, depleted compression depth) was summarized and compared between conditions. Results: A total of 10, 203 individual compressions from 10 participants were analyzed. The mean depleted compression depths (percentage depletion) secondary to mattress effect were the following: 23.6 mm (29.7%) on a mattress only, 13.7 mm (19.5%) on a CPR board, 16.9 mm (23.1%) on a slider transfer board, 11.9 mm (17.3%) on a slider transfer board plus backboard, and 10.3 mm (15.4%) on a flat spine board. The differences in percentage depletion across conditions were statistically significant. Conclusion: Cardiopulmonary resuscitation providers should use a CPR board and slider transfer board or a flat spine board alone because these conditions are associated with the smallest amount of mattress compressibility. … (more)
- Is Part Of:
- Simulation in healthcare. Volume 12:Issue 6(2017)
- Journal:
- Simulation in healthcare
- Issue:
- Volume 12:Issue 6(2017)
- Issue Display:
- Volume 12, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 12
- Issue:
- 6
- Issue Sort Value:
- 2017-0012-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-12
- Subjects:
- Cardiopulmonary resuscitation -- quality -- resuscitation -- chest compressions -- mattress
Simulated patients -- Periodicals
362.1 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01253104-000000000-00000 ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01266021-000000000-00000 ↗
http://journals.lww.com/simulationinhealthcare/pages/default.aspx ↗
http://www.simulationinhealthcare.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/SIH.0000000000000245 ↗
- Languages:
- English
- ISSNs:
- 1559-2332
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8285.164020
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8648.xml