Bigger is better: Comparison of alternative devices for tension hemopneumothorax and pulseless electrical activity in a Yorkshire swine model. Issue 6 (December 2017)
- Record Type:
- Journal Article
- Title:
- Bigger is better: Comparison of alternative devices for tension hemopneumothorax and pulseless electrical activity in a Yorkshire swine model. Issue 6 (December 2017)
- Main Title:
- Bigger is better
- Authors:
- Leatherman, Matthew L.
Fluke, Laura M.
McEvoy, Christian S.
Pokorny, Douglas M.
Ricca, Robert L.
Martin, Matthew J.
Gamble, Christopher S.
Polk, Travis M. - Abstract:
- Abstract : BACKGROUND: Tension pneumothorax is a cause of potentially preventable death in prehospital and battlefield settings and 14-gauge angiocatheter (14G AC) decompression remains the current treatment standard, despite its high incidence of failure. Traumatic pneumothorax is often associated with hemothorax, but 14G AC has no proven efficacy for associated hemothorax. We sought to compare the 14G AC to three alternative devices for treatment of tension hemopneumothorax (t-H/PTX) in a positive-pressure ventilation swine model. METHODS: Our tension model was modified to incorporate a persistent air leak and pleural blood. Tension physiology was achieved with escalating carbon dioxide insufflation via transdiaphragmatic trocar, and 10% estimated blood volume was instilled into each chest. Intervention was randomized between 14G AC, 10-gauge angiocatheter (10G AC), modified Veress-type needle (mVN), and 3-mm laparoscopic trocar (LT). After recovery, serial tension-induced pulseless electrical activity (PEA) events were induced and decompressed. Success of rescue, time to rescue, and physiologic data were recorded. RESULTS: One hundred ninety-five t-H/PTX and 88 PEA events were conducted in 25 swine. Laparoscopic trocar and 10G AC were more successful and had faster median time to rescue for t-H/PTX compared with 14G AC, whereas mVN performed comparably. Following PEA, 14G AC and mVN succeeded at rescue only 50% and 57% of the time, whereas 10G AC and LT had 100% successAbstract : BACKGROUND: Tension pneumothorax is a cause of potentially preventable death in prehospital and battlefield settings and 14-gauge angiocatheter (14G AC) decompression remains the current treatment standard, despite its high incidence of failure. Traumatic pneumothorax is often associated with hemothorax, but 14G AC has no proven efficacy for associated hemothorax. We sought to compare the 14G AC to three alternative devices for treatment of tension hemopneumothorax (t-H/PTX) in a positive-pressure ventilation swine model. METHODS: Our tension model was modified to incorporate a persistent air leak and pleural blood. Tension physiology was achieved with escalating carbon dioxide insufflation via transdiaphragmatic trocar, and 10% estimated blood volume was instilled into each chest. Intervention was randomized between 14G AC, 10-gauge angiocatheter (10G AC), modified Veress-type needle (mVN), and 3-mm laparoscopic trocar (LT). After recovery, serial tension-induced pulseless electrical activity (PEA) events were induced and decompressed. Success of rescue, time to rescue, and physiologic data were recorded. RESULTS: One hundred ninety-five t-H/PTX and 88 PEA events were conducted in 25 swine. Laparoscopic trocar and 10G AC were more successful and had faster median time to rescue for t-H/PTX compared with 14G AC, whereas mVN performed comparably. Following PEA, 14G AC and mVN succeeded at rescue only 50% and 57% of the time, whereas 10G AC and LT had 100% success at return of spontaneous circulation. Time to successful return of circulation following PEA did not differ between devices; however, there was a noticeable difference in the rate of meaningful hemodynamic recovery following PEA favoring LT and 10G AC. There were no significant injuries noted. CONCLUSIONS: While mVN performed comparably to 14G AC, both have unacceptable failure rates. Ten-gauge AC and LT performed superiorly in both t-H/PTX and PEA. We believe there is now ample evidence supporting replacement of the 14G AC with 10G AC in current treatment recommendations. Abstract : Supplemental digital content is available in the text. … (more)
- Is Part Of:
- Journal of trauma and acute care surgery. Volume 83:Issue 6(2017)
- Journal:
- Journal of trauma and acute care surgery
- Issue:
- Volume 83:Issue 6(2017)
- Issue Display:
- Volume 83, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 83
- Issue:
- 6
- Issue Sort Value:
- 2017-0083-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-12
- Subjects:
- Tension hemopneumothorax -- modified Veress needle -- 14-gauge angiocatheter -- 10-gauge angiocatheter -- laparoscopic trocar -- swine
Surgical intensive care -- Periodicals
Surgical emergencies -- Periodicals
Wounds and injuries -- Surgery -- Periodicals
617.026 - Journal URLs:
- http://journals.lww.com/jtrauma/pages/default.aspx ↗
http://ovidsp.tx.ovid.com/sp-3.5.0b/ovidweb.cgi?&S=NEIKFPIGHGDDBOHLNCALMDIBGLDKAA00&Browse=Toc+Children%7cNO%7cS.sh.2697_1327404888_15.2697_1327404888_27.2697_1327404888_28%7c273%7c50 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/TA.0000000000001684 ↗
- Languages:
- English
- ISSNs:
- 2163-0755
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5070.510500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8650.xml